S13 · Lesson 13 · Radiometry and photometry
Measuring light: flux, irradiance, intensity and radiance, Lambertian sources and the inverse-square law, why no optic can raise radiance, blackbody emission, and the photometric units that weight light by the eye's response
A laser's beam and a light bulb can carry the same watts, yet one cuts steel and the other lights a room. Radiometry gives the vocabulary that separates them: how much power there is, how it spreads over area and over angle, and how concentrated it is in both at once. Photometry then weights each watt by how bright it looks to the eye, which is how lamps, displays and cameras are specified.
- The curve is a blackbody's spectral exitance against wavelength, , in MW/m² per µm, at the temperature on the slider.
- The peak moves to shorter wavelengths as ; a 2800 K filament peaks at 1.03 µm, in the infrared.
- The shaded band, 400 to 700 nm, holds only 6% of a 2800 K filament's output but 37% of the Sun's (5800 K).
Predict
A 1 W laser at 555 nm and a 1 W laser at 650 nm shine on a wall. How do their luminous fluxes compare?
Luminous flux weights each watt by the eye's sensitivity V(λ), which peaks at 555 nm (where 1 W is 683 lm by definition) and is only 0.107 at 650 nm. The red laser looks about a ninth as bright, though it carries the same power.
Name it
Radiometric quantities
- Flux Φ (W): total power.
- Irradiance E (W/m²): power arriving per unit area; exitance M: leaving per unit area.
- Intensity I (W/sr): power per unit solid angle from a small source.
- Radiance L (W/(m²·sr)): power per unit projected area per unit solid angle, the "brightness" of an extended source.
A point source of intensity I gives an irradiance at distance d (the inverse-square law). A Lambertian surface has the same radiance in every direction, so its intensity falls as cos θ, and its exitance is ; a small Lambertian emitter of flux Φ has on-axis intensity .
Conservation of radiance
No passive optical system can make an image brighter (in radiance) than its source; lenses trade area for angle. This sets the most sunlight can be concentrated: with the Sun's half-angle = 4.65 mrad, suns. Lasers are useful for exactly this reason: their radiance is enormous.
Blackbodies
A blackbody at temperature T emits in all (σ = 5.67 × 10⁻⁸ W/(m²·K⁴)), with spectral peak at (Wien's law).
Photometry
Photometric units weight power by the eye's photopic response V(λ), normalized to 1 at 555 nm:
The lumen (lm) is luminous flux, the candela (cd = lm/sr) luminous intensity, the lux (lm/m²) illuminance. A source's luminous efficacy is lumens per watt.
Worked example
A white LED emits 100 lm as a Lambertian source. What is its on-axis intensity, and what illuminance does it give 2 m away on axis and 30° off axis?
Show the solution
- On-axis intensity. For a Lambertian source,
- On axis at 2 m.
- At 30° off axis. The intensity falls to and, on a surface facing the LED at the same distance, the illuminance falls to 6.89 lux.
- For comparison. A reading lamp wants several hundred lux, which is why lamps use several LEDs or optics that narrow the beam.
Answer the LED's on-axis intensity is 31.8 cd, giving 7.96 lux on axis at 2 m and 6.89 lux at 30° off axis.
Worked example
Find the peak wavelength and total exitance of a 2800 K tungsten filament and of the 5800 K Sun, and the share of each in 400 to 700 nm.
Show the solution
- Peak wavelengths. Wien's law gives
- Total exitance. Stefan–Boltzmann gives
- Visible share. Integrating Planck's law over 400 to 700 nm gives 6.0% of the filament's output against 36.8% of the Sun's.
- What that means for lamps. An incandescent lamp is mostly a heater, which is why its luminous efficacy is only about 15 lm/W.
Answer the filament peaks at 1.03 µm and emits 3.49 MW/m², 6.0% of it in 400 to 700 nm; the Sun peaks at 0.50 µm and emits 64.2 MW/m², 36.8% of it in that band.
Worked example
How much can mirrors or lenses concentrate sunlight, and what does that imply for the temperature at the focus?
Show the solution
- Maximum concentration.
- What the focus sees. At that concentration the focus receives the same radiance from every direction as the Sun's surface, so an ideal absorber there would reach the Sun's 5800 K and no higher. Real solar furnaces reach about 3500 K.
- Why no optics can do better. No arrangement of lenses can exceed this, because that would make heat flow from a cooler body to a hotter one.
Answer sunlight can be concentrated at most about 46 000 times, which could bring an ideal absorber up to the Sun's 5800 K but no higher.
Check
A Lambertian source emits 500 lm; a surface faces it 1 m away, 60° off its axis.
(a)
What is the source's intensity toward the surface?
(b)
What illuminance does the surface receive?
Check
A blackbody is at 2800 K.
(a)
At what wavelength does its spectrum peak?
Write units the way you normally would: 1.5 µm, 1500 nm and 0.0015 mm are the same answer.
(b)
What is its total exitance?
Check
A laser emits 1 W at a wavelength where the eye's relative sensitivity is 0.107.
(a)
What is its luminous flux?
Check
A source subtends a half-angle of 1°; an optic of 1 cm² collects its light.
(a)
What is the greatest concentration any optic can reach?
(b)
What is the smallest spot it can squeeze the light into?
Check
A small source of 100 cd lights a surface 0.5 m away whose normal is tilted 60° from the line to the source.
(a)
What illuminance does the surface get?
Check
Why can't a lens make a sunlit spot hotter than the surface of the Sun?
Check
A small Lambertian emitter of radiance L and area A is viewed from distance d at t degrees from its normal.
Step 1
What is its intensity in that direction?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What is its total flux?
Step 3
What irradiance does a surface facing it receive?
Check
Write planck(l, T): a blackbody's spectral exitance in W/m² per meter of wavelength, and band_fraction(T, l1, l2): the fraction of between two wavelengths, by Simpson's rule with 2000 intervals.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Explain why
Why is radiance, rather than power or irradiance, the measure of how useful a light source is for focusing?
Focusing collects light spread over a range of positions and directions and squeezes it into a smaller area, but optics can only trade area for angle: the product of the two, the étendue, can't shrink without losing light. Radiance is power per unit area per unit solid angle, so it stays the same through any lossless system, and the irradiance at a focus is at most the radiance times the solid angle the optic fills. A source with high radiance, like a laser emitting from a tiny area into a tiny angle, can be focused to enormous irradiance; a large, diffuse source of the same power cannot, however good the lens.
Practice
Keep practicing
8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.