title: "Problem set 3: temperature, biopotentials and the ECG"
heading: "Problem set 3: thermistors, RTDs, thermocouples and self-heating, Nernst and Goldman potentials, cable constants and conduction velocity, dipole potentials, and ECG leads, axis, rate and QT"
eyebrow: S15 · Problem set 3
type: problems
---

::: hook
These problems cover lessons 7 to 12: thermistor resistance and coefficients, platinum and thermocouple readings, self-heating, Nernst potentials for single and double charges, the Goldman and parallel-conductance models, length and time constants, conduction studies, dipoles in tissue, and Einthoven's leads with the electrical axis, heart rate and corrected QT.
:::

::: pool
pick: 12

::: check
kind: parts
given: R = 5 | 20; B = 3500 | 4200; T = 35 | 39

## A thermistor of {R} kΩ at 25 °C with B = {B} K, at {T} °C.

::: part
answer: R*exp(B*(1/(T + 273.15) - 1/298.15))
unit: kΩ
tolerance: 0.5%

### Resistance?

::: misses
- [any] The B equation in kelvins.
:::
:::

::: part
answer: -100*B/(T + 273.15)^2
unit: %/°C
tolerance: 0.5%

### Coefficient in %/°C?

::: misses
- [any] $-B/T^2$.
:::
:::

::: part
answer: R*exp(B*(1/(T + 273.15) - 1/298.15))*B/(T + 273.15)^2*1000
unit: Ω
tolerance: 0.5%

### About how many ohms per °C?

::: misses
- [any] $|\alpha|R$.
:::
:::
:::

::: check
kind: parts
given: R = 100 | 1000; T = 30 | 40; S = 40 | 50; d = 8 | 25

## A platinum RTD with $R_0$ = {R} Ω; a thermocouple of {S} µV/°C.

::: part
answer: R*(1 + 0.00385*T)
unit: Ω
tolerance: 0.05%

### RTD resistance at {T} °C?

::: misses
- [any] $R_0(1 + 0.00385T)$.
:::
:::

::: part
answer: S*d
unit: µV
tolerance: 0.5%

### Thermocouple voltage for a {d} °C difference?

::: misses
- [any] $S\Delta T$.
:::
:::
:::

::: check
kind: parts
given: I = 20 | 100; R = 4 | 12; d = 1 | 4; T = 30 | 40

## A {R} kΩ thermistor carrying {I} µA with dissipation constant {d} mW/°C; a body at {T} °C.

::: part
answer: (I*1e-6)^2*R*1e3/(d*1e-3)
unit: °C
tolerance: 0.5%

### Self-heating?

::: misses
- [any] $I^2R/\delta$.
:::
:::

::: part
answer: 2898/(T + 273.15)
unit: µm
tolerance: 0.5%

### Peak emission wavelength?

::: misses
- [any] Wien's law.
:::
:::
:::

::: check
kind: parts
given: i = 130 | 150; o = 4 | 7; c = 1 | 2.5; e = 0.0001 | 0.0003

## Potassium {i} mM inside and {o} mM outside; calcium {c} mM outside and {e} mM inside; 37 °C.

::: part
answer: 26.727*ln(o/i)
unit: mV
tolerance: 0.5%

### Potassium's Nernst potential?

::: misses
- [any] $(RT/F)\ln([K]_o/[K]_i)$.
:::
:::

::: part
answer: 26.727/2*ln(c/e)
unit: mV
tolerance: 0.5%

### Calcium's?

::: misses
- [any] z = 2.
:::
:::
:::

::: check
kind: parts
given: r = 0.02 | 0.08; K = 3.5 | 7; a = 1 | 1.5; b = 0.03 | 0.3; c = 0.2 | 0.5

## A K⁺/Na⁺ membrane with $P_{Na}/P_K$ = {r} (140/{K} mM K⁺, 12/145 mM Na⁺, inside/outside); separately, conductances {a}, {b}, {c} for K⁺, Na⁺, Cl⁻ with Nernst potentials −95, +66.6 and −90 mV.

::: part
answer: 26.727*ln((K + 145*r)/(140 + 12*r))
unit: mV
tolerance: 0.5%

### GHK potential?

::: misses
- [any] Permeability-weighted concentrations.
:::
:::

::: part
answer: (a*(-95) + b*66.6 + c*(-90))/(a + b + c)
unit: mV
tolerance: 0.5%

### Parallel-conductance potential?

::: misses
- [any] $\sum gE/\sum g$.
:::
:::
:::

::: check
kind: parts
given: C = 1 | 1.5; V = 80 | 110; A = 1 | 10

## A membrane of {C} µF/cm² and area {A} × 10⁻⁵ cm² swings by {V} mV.

::: part
answer: C*V*1e-3
unit: µC/cm²
tolerance: 0.5%

### Charge per area, in µC/cm²?

::: misses
- [any] $C\Delta V$.
:::
:::

::: part
answer: C*1e-6*V*1e-3*A*1e-5/1.602176634e-19
tolerance: 0.5%

### Number of monovalent ions?

::: misses
- [any] Charge over e.
:::
:::
:::

::: check
kind: parts
given: d = 1 | 5; M = 4000 | 15000; R = 80 | 200; c = 1 | 1.2; V = 15 | 30; x = 0.5 | 1.5

## An axon {d} µm across, $R_m$ = {M} Ω·cm², $R_i$ = {R} Ω·cm, $C_m$ = {c} µF/cm².

::: part
answer: 10*sqrt(M*d*1e-4/(4*R))
unit: mm
tolerance: 0.5%

### Length constant?

::: misses
- [any] $\sqrt{R_md/4R_i}$.
:::
:::

::: part
answer: M*c*1e-3
unit: ms
tolerance: 0.5%

### Time constant?

::: misses
- [any] $R_mC_m$.
:::
:::

::: part
answer: V*exp(-x/(10*sqrt(M*d*1e-4/(4*R))))
unit: mV
tolerance: 0.5%

### What's left of a steady {V} mV at {x} mm?

::: misses
- [any] $V_0e^{-x/\lambda}$.
:::
:::
:::

::: check
kind: parts
given: L = 20 | 30; a = 3 | 4.5; b = 8 | 10; d = 4 | 12; D = 0.5 | 1

## A conduction study with sites {L} cm apart and latencies {b} and {a} ms; a myelinated fiber {d} µm across.

::: part
answer: L*1e-2/((b - a)*1e-3)
unit: m/s
tolerance: 0.5%

### Conduction velocity?

::: misses
- [any] Δx/Δt.
:::
:::

::: part
answer: D/(6*d)*1000
unit: ms
tolerance: 0.5%

### Travel time over {D} m for the fiber?

::: misses
- [any] 6 m/s per µm.
:::
:::
:::

::: check
kind: parts
given: p = 1.5 | 4; t = 20 | 50; r = 12 | 25; s = 0.2 | 0.3

## A {p} × 10⁻⁵ A·m dipole in tissue of {s} S/m.

::: part
answer: p*1e-5*cos(t*pi/180)/(4*pi*s*(r/100)^2)*1000
unit: mV
tolerance: 0.5%

### Potential {r} cm away at {t}°?

::: misses
- [any] $p\cos\theta/(4\pi\sigma r^2)$.
:::
:::

::: part
answer: p*1e-5*cos(t*pi/180)/(4*pi*s*(2*r/100)^2)*1000
unit: mV
tolerance: 0.5%

### At twice the distance?

::: misses
- [any] Falls as $1/r^2$.
:::
:::
:::

::: check
kind: parts
given: a = 0.4 | 0.9; b = 0.6 | 1.3

## Lead I reads {a} mV and lead II {b} mV.

::: part
answer: b - a
unit: mV
tolerance: 0.5%

### Lead III?

::: misses
- [any] II − I.
:::
:::

::: part
answer: (a - (b - a))/2
unit: mV
tolerance: 0.5%

### aVL?

::: misses
- [any] (I − III)/2.
:::
:::

::: part
answer: atan((2*b - a)/(sqrt(3)*a))*180/pi
unit: °
tolerance: 0.5%

### Electrical axis?

::: misses
- [any] $\tan^{-1}[(2\,\text{II} - \text{I})/(\sqrt{3}\,\text{I})]$.
:::
:::
:::

::: check
kind: parts
given: M = 0.7 | 1.6; t = 10 | 70; f = -150 | -30 | 90

## A heart vector of {M} mV at {t}°.

::: part
answer: M*cos(t*pi/180)
unit: mV
tolerance: 0.5%

### Lead I?

::: misses
- [any] $M\cos\theta$.
:::
:::

::: part
answer: sqrt(3)/2*M*cos((t - f)*pi/180)
unit: mV
tolerance: 0.5%

### The augmented lead along {f}°?

::: misses
- [any] $\frac{\sqrt{3}}{2}M\cos(\theta - \varphi)$.
:::
:::
:::

::: check
kind: parts
given: D = 15 | 25; s = 25 | 50; q = 0.34 | 0.42

## R waves {D} mm apart at {s} mm/s, with a QT of {q} s.

::: part
answer: 60*s/D
tolerance: 0.5%

### Heart rate per minute?

::: misses
- [any] $60s/D$.
:::
:::

::: part
answer: q/sqrt(D/s)
unit: s
tolerance: 0.5%

### Bazett's corrected QT?

::: misses
- [any] $QT/\sqrt{RR}$.
:::
:::
:::

::: check
kind: parts
given: k = 4 | 5; K = 7 | 9; p = 0.03 | 0.05

## Extracellular potassium rises from {k} to {K} mM; K⁺ is 140 mM inside, Na⁺ 12/145 mM and Cl⁻ 4/120 mM (inside/outside), with $P_K : P_{Na} : P_{Cl}$ = 1 : {p} : 0.45, at 37 °C.

::: part
answer: 26.73*ln(K/k)
unit: mV
tolerance: 0.5%

### How far does the potassium Nernst potential rise?

::: misses
- [any] $(RT/F)\ln(K/k)$.
:::
:::

::: part
answer: 26.73*ln((K + p*145 + 0.45*4)/(140 + p*12 + 0.45*120)) - 26.73*ln((k + p*145 + 0.45*4)/(140 + p*12 + 0.45*120))
unit: mV
tolerance: 0.5%

### How far does the resting potential rise?

::: misses
- [26.73*ln(K/k)] Sodium and chloride hold the membrane back; use the Goldman equation.
- [any] The difference of two Goldman potentials.
:::
:::
:::

::: check
kind: parts
given: c = 2 | 3 | 12; f = 250 | 500; b = 12 | 16; G = 16 | 32

## A Holter recorder stores {c} channels at {f} samples a second and {b} bits for 24 hours, on {G} MB of memory.

::: part
answer: c*f*b*86400/8/1e6
unit: MB
tolerance: 0.5%

### How much raw data does a day produce?

::: misses
- [any] Channels × rate × bits × 86,400 s, over 8.
:::
:::

::: part
answer: c*f*b*86400/8/1e6/G
tolerance: 0.5%

### What compression ratio fits it?

::: misses
- [any] Raw size over memory.
:::
:::
:::

::: check
kind: parts
given: R = 5 | 10; B = 3400 | 3900; T = 25 | 37

## A {R} kΩ thermistor (at 25 °C, B = {B} K) is to be linearized around {T} °C with a parallel resistor.

::: part
answer: R*exp(B*(1/(T + 273.15) - 1/298.15))*(B - 2*(T + 273.15))/(B + 2*(T + 273.15))
unit: kΩ
tolerance: 0.5%

### What resistor puts the inflection at {T} °C?

::: misses