title: "Problem set 7: catheterization, respiration, oximetry and chemistry"
heading: "Problem set 7: valve areas and Doppler gradients, kinetic-energy errors, catheters with bubbles, oscillometric envelopes, thermodilution, pulse-wave velocity, BTPS volumes, lung volumes, mechanics and work of breathing, oximetry and oxygen content, blood gases and enzyme sensors, and the laboratory's photometers and counters"
eyebrow: S15 · Problem set 7
type: problems
---

::: hook
These problems cover lessons 23 to 35, weighted toward what the earlier sets didn't reach: catheterization and the cardiovascular lab's processing, then the respiratory system, oxygen and carbon dioxide, and the chemical and laboratory measurements that read blood itself.
:::

::: pool
pick: 12

::: check
kind: parts
given: Q = 4 | 6; H = 65 | 85; t = 0.28 | 0.34; P = 15 | 50; v = 2.5 | 4.5

## Cardiac output is {Q} L/min at {H} per minute, with {t} s of ejection per beat and a mean aortic-valve gradient of {P} mmHg; separately, Doppler measures a {v} m/s jet.

::: part
answer: Q*1e-3/H/t/(0.85*sqrt(2*P*133.322/1060))*1e4
unit: cm^2
tolerance: 0.5%

### What is the valve's area?

::: misses
- [any] $F/(c_d\sqrt{2\Delta P/\rho})$ with $c_d$ = 0.85.
:::
:::

::: part
answer: 4*v^2
unit: mmHg
tolerance: 1%

### What gradient does the simplified Bernoulli equation give for the jet?

::: misses
- [any] $4v^2$.
:::
:::
:::

::: check
kind: parts
given: v = 0.9 | 1.5 | 3; P = 15 | 25 | 120

## An end-hole catheter faces blood flowing at {v} m/s where the static pressure is {P} mmHg.

::: part
answer: 1060*v^2/2/133.322
unit: mmHg
tolerance: 0.5%

### By how much does it read high?

::: misses
- [any] $\rho u^2/2$.
:::
:::

::: part
answer: 1060*v^2/2/133.322/P*100
unit: %
tolerance: 0.5%

### What percent error is that?

::: misses
- [any] Over the static pressure.
:::
:::
:::

::: check
kind: parts
given: r = 0.4 | 0.6; L = 0.9 | 1.5; c = 0.01 | 0.05; b = 0.5 | 2

## A saline catheter of radius {r} mm and length {L} m feeds a transducer of {c} mm³ per 100 mmHg, with a {b} mm³ air bubble trapped in the dome.

::: part
answer: r*1e-3/2*sqrt(1/(c*1e-9/(100*133.32) + b*1e-9/101325)/(pi*1000*L))
unit: Hz
tolerance: 0.5%

### What is the natural frequency?

::: misses
- [r*1e-3/2*sqrt(1/(c*1e-9/(100*133.32))/(pi*1000*L))] The bubble's compliance, $V_b/P_\text{atm}$, adds to the transducer's.
- [any] $\frac r2\sqrt{E_d/\pi\rho L}$ with the combined elasticity.
:::
:::

::: part
answer: 4*0.001/(r*1e-3)^3*sqrt(L/(pi*1000/(c*1e-9/(100*133.32) + b*1e-9/101325)))
tolerance: 0.5%

### What is the damping ratio?

::: misses
- [any] $\frac{4\eta}{r^3}\sqrt{L/\pi\rho E_d}$.
:::
:::
:::

::: check
kind: parts
given: M = 85 | 100; w = 25 | 35

## An oscillometric envelope follows $e^{-((P - \text{MAP})/w)^2}$ with MAP = {M} mmHg and w = {w} mmHg; the monitor uses ratios of 0.55 and 0.85.

::: part
answer: M + w*sqrt(-ln(0.55))
unit: mmHg
tolerance: 0.5%

### What systolic pressure does it report?

::: misses
- [M + w*sqrt(-ln(0.85))] Systolic uses the 0.55 ratio, above the mean.
- [any] Where the envelope falls to 0.55 above MAP.
:::
:::

::: part
answer: M - w*sqrt(-ln(0.85))
unit: mmHg
tolerance: 0.5%

### What diastolic pressure?

::: misses
- [any] Where it falls to 0.85 below MAP.
:::
:::
:::

::: check
kind: parts
given: V = 5 | 10; T = 0 | 20; A = 2.5 | 4.4 | 7; H = 60 | 90

## {V} mL of injectate at {T} °C enters blood at 37 °C; the temperature curve's area is {A} °C·s, with K = 1.08, at {H} beats per minute.

::: part
answer: V*(37 - T)*1.08/A*60/1000
unit: L/min
tolerance: 0.5%

### What is the cardiac output?

::: misses
- [V*(37 - T)*1.08/A] That's in mL/s.
- [any] $V_i(T_b - T_i)K/\int\Delta T\,dt$.
:::
:::

::: part
answer: V*(37 - T)*1.08/A*60/H
unit: mL
tolerance: 0.5%

### What is the stroke volume?

::: misses
- [any] Output over heart rate.
:::
:::
:::

::: check
kind: parts
given: E = 0.4 | 1; h = 0.4 | 0.8; d = 8 | 16; L = 0.6 | 0.9; k = 1.1 | 1.3

## An artery's wall has E = {E} MPa and thickness {h} mm with a {d} mm lumen; a pulse travels {L} m, and a pressure rise stiffens the wall by a factor of {k}.

::: part
answer: L/sqrt(E*1e6*h*1e-3/(1060*d*1e-3))*1e3
unit: ms
tolerance: 0.5%

### How long does the pulse take?

::: misses
- [any] Distance over the Moens–Korteweg velocity.
:::
:::

::: part
answer: L/sqrt(E*1e6*h*1e-3/(1060*d*1e-3))*1e3*(1 - 1/sqrt(k))
unit: ms
tolerance: 0.5%

### How much shorter does the stiffening make it?

::: misses
- [any] Velocity scales as √k.
:::
:::
:::

::: check
kind: parts
given: V = 3 | 4.5; T = 20 | 25; W = 17.5 | 23.8; P = 700 | 760

## A spirometer at {T} °C (water vapor {W} mmHg) and {P} mmHg measures a vital capacity of {V} L.

::: part
answer: V*310/(273 + T)*(P - W)/(P - 47)
unit: L
tolerance: 0.5%

### What is it at body conditions (BTPS)?

::: misses
- [V*310/(273 + T)] Correct for water vapor as well as temperature.
- [any] $V\frac{310}{273 + T}\frac{P_B - P_{H_2O}}{P_B - 47}$.
:::
:::
:::

::: check
kind: parts
given: S = 5 | 8; a = 8 | 10; b = 5.5 | 6.5; P = 950 | 1000; v = 20 | 40; p = 1 | 1.5

## A helium spirometer of {S} L starts at {a}% helium and settles at {b}% after the subject joins at FRC; separately, a body box at {P} cmH₂O alveolar pressure shows a {v} mL compression for a {p} cmH₂O rise.

::: part
answer: S*(a - b)/b
unit: L
tolerance: 0.5%

### What FRC does helium dilution give?

::: misses
- [S*a/b] Subtract the spirometer's own volume.
- [any] $V(C_1 - C_2)/C_2$.
:::
:::

::: part
answer: v*1e-3*P/p
unit: L
tolerance: 0.5%

### What thoracic gas volume does the body box give?

::: misses
- [any] Boyle's law: $V = \Delta V\cdot P/\Delta P$.
:::
:::
:::

::: check
kind: parts
given: R = 2 | 8; C = 0.05 | 0.1; I = 0.01 | 0.02; V = 0.5 | 0.8; t = 1 | 1.5; f = 12 | 25

## A respiratory system has R = {R} cmH₂O·s/L, C = {C} L/cmH₂O and inertance {I} cmH₂O·s²/L; it breathes {V} L at constant flow over {t} s, {f} times a minute.

::: part
answer: 1/(2*pi*sqrt(I*C))
unit: Hz
tolerance: 0.5%

### At what frequency is it resonant?

::: misses
- [1/sqrt(I*C)] That's in radians per second.
- [any] $1/(2\pi\sqrt{IC})$.
:::
:::

::: part
answer: (0.5*V^2/C + R*V^2/t)*0.0980665*f/60
unit: W
tolerance: 0.5%

### What power do the muscles deliver?

::: misses
- [any] Elastic plus resistive work per breath, times breaths per second.
:::
:::
:::

::: check
kind: parts
given: a = 0.008 | 0.012; b = 1 | 1.2; c = 0.015 | 0.02; d = 1 | 1.3; H = 12 | 15; P = 60 | 95

## An oximeter reads red AC/DC = {a}/{b} and infrared AC/DC = {c}/{d}, calibrated as SpO₂ = 110 − 25R; the patient has {H} g/dL of hemoglobin and a $P_aO_2$ of {P} mmHg.

::: part
answer: 110 - 25*(a/b)/(c/d)
unit: %
tolerance: 0.5%

### What saturation does it display?

::: misses
- [110 - 25*(c/d)/(a/b)] R is red over infrared.
- [any] 110 − 25R.
:::
:::

::: part
answer: 1.34*H*(110 - 25*(a/b)/(c/d))/100 + 0.003*P
unit: mL/dL
tolerance: 0.5%

### What oxygen content does that imply?

::: misses
- [1.34*H*(110 - 25*(a/b)/(c/d))/100] Add the dissolved oxygen, 0.003 mL/dL per mmHg.
- [any] $1.34\,\text{Hb}\,S + 0.003P_aO_2$.
:::
:::
:::

::: check
kind: parts
given: b = 18 | 24 | 30; p = 30 | 40 | 60; r = 1.5 | 3

## Blood has {b} mM bicarbonate and a $P_{CO_2}$ of {p} mmHg; a Severinghaus electrode at 37 °C then sees $P_{CO_2}$ rise by a factor of {r}.

::: part
answer: 6.1 + log(b/(0.03*p))
tolerance: 0.5%

### What is the blood's pH?

::: misses
- [6.1 + ln(b/(0.03*p))] Henderson–Hasselbalch uses log₁₀.
- [any] $6.1 + \log(b/0.03P_{CO_2})$.
:::
:::

::: part
answer: 61.54*log(r)
unit: mV
tolerance: 0.5%

### How much does the electrode's output change?

::: misses
- [any] 61.5 mV per tenfold change in $P_{CO_2}$.
:::
:::
:::

::: check
kind: parts
given: m = 50 | 200; K = 10 | 25; G = 4 | 8 | 15; f = 0.05 | 0.5; n = 2 | 4

## A glucose sensor has $i_\max$ = {m} nA and $K_m$ = {K} mM; separately, an amperometric sensor reacts {f} pmol/s with {n} electrons each.

::: part
answer: m*G/(K + G)
unit: nA
tolerance: 0.5%

### What current does the glucose sensor give at {G} mM?

::: misses
- [m*G/K] That's the linear approximation; the enzyme saturates.
- [any] $i_\max G/(K_m + G)$.
:::
:::

::: part
answer: n*96485.33212*f*1e-12*1e9
unit: nA
tolerance: 0.5%

### What current does the amperometric reaction carry?

::: misses
- [any] $nF$ times the molar rate.
:::
:::
:::

::: check
kind: parts
given: C = 5 | 10; s = 30 | 50; u = 40 | 70; N = 4 | 5; D = 20000 | 100000

## A photometer's standard of {C} mg/dL reads {s}% transmittance and a sample {u}%; separately, blood with {N} million cells/µL is diluted 1:{D} into a counter whose 80 µm, 100 µm long aperture holds a volume of 5.03 × 10⁻⁴ µL.

::: part
answer: C*log(u/100)/log(s/100)
unit: mg/dL
tolerance: 0.5%

### What is the sample's concentration?

::: misses
- [C*u/s] Concentration follows absorbance, −log T, not transmittance.
- [any] Ratio of absorbances times the standard.
:::
:::

::: part
answer: 1 - exp(-N*1e6/D*5.03e-4)
tolerance: 0.5%

### What is the chance of a second cell in the aperture when one passes?

::: misses
- [any] $1 - e^{-\lambda}$ with λ the average number in the aperture.
:::
:::
:::

::: check
kind: parts
given: F = 3 | 4.5 | 5.5; u = 0.3 | 0.6 | 1.2

## A forced expiration follows the single-exponential model with FVC = {F} L and time constant {u} s.

::: part
answer: 1 - exp(-1/u)
tolerance: 0.5%

### What is FEV₁/FVC?

::: misses
- [exp(-1/u)] That's the fraction still in the lungs after one second.
- [any] $1 - e^{-1/\tau}$.
:::
:::

::: part
answer: F/u
unit: L/s
tolerance: 0.5%

### What is the peak flow?

::: misses
- [any] The initial slope, FVC/τ.
:::
:::
:::

::: check
kind: parts
given: a = 38 | 45; e = 22 | 28; V = 400 | 600; f = 12 | 24

## Arterial $P_{CO_2}$ is {a} mmHg and mixed expired $P_{CO_2}$ {e} mmHg, in a patient breathing {V} mL at {f} breaths per minute.

::: part
answer: (a - e)/a
tolerance: 0.5%

### What fraction of each breath is dead space?

::: misses
- [e/a] That's the alveolar fraction.
- [any] Bohr: $(P_aCO_2 - P_ECO_2)/P_aCO_2$.
:::
:::

::: part
answer: V*(1 - (a - e)/a)*f/1000
unit: L/min
tolerance: 0.5%

### What is the alveolar ventilation?

::: misses
- [V*f/1000] That's the minute ventilation; subtract the dead space.
- [any] $(V_T - V_D)f$.
:::
:::
:::
:::