title: Resistive sensors and bridges
heading: Potentiometric displacement sensors and their loading error, strain gauges and the gauge factor, the Wheatstone bridge with one, two and four active arms, the quarter bridge's nonlinearity, and temperature effects cancelled by bridge arrangement
eyebrow: S15 · Lesson 3 · Resistive sensors and bridges
xp: 50
---

::: hook
Most blood-pressure transducers, load cells in hospital beds and force plates in gait labs are strain gauges: thin metal or silicon patterns whose resistance changes by a fraction of a percent when stretched. A change that small is invisible against the resistance itself, and it drifts with temperature by as much as the signal. The Wheatstone bridge, met in C1, solves both problems at once: it subtracts the unchanging part, and with the gauges arranged so that strain pushes them in opposite directions and temperature pushes them together, the drift cancels while the signal adds.
:::

::: play
- A Wheatstone bridge excited by V with one, two or four active arms. Each active gauge changes by ±ΔR, with the signs arranged so the outputs add.
- The quarter bridge's exact output, $V\frac{x}{2(2 + x)}$ with x = ΔR/R, bends away from the linear $Vx/4$ as x grows. The half and full bridges stay exactly linear.
- At the strains of real gauges (x of a few thousandths) the bend is a fraction of a percent, but semiconductor gauges reach x of several percent.
:::

```sim plot
view: graph
x: x = 0..0.2
y: v = 0..1.05
slider: V = 1..10 step 0.5 = 5
plot: V*x/(2*(2 + x)) | samples: 300 | label: quarter bridge (exact)
plot: V*x/4 | samples: 50 | dashed | color: ch3 | label: quarter bridge (linear)
plot: V*x/2 | samples: 50 | color: ch4 | label: half bridge
plot: V*x | samples: 50 | color: ch5 | label: full bridge
readout: quarter-bridge error at x of 0.1, % = 100*(0.1/4 - 0.1/(2*2.1))/(0.1/(2*2.1)) | digits: 3
```

::: predict
## A 350 Ω foil gauge with gauge factor 2 is strained by 500 microstrain in a quarter bridge excited at 5 V. What's the bridge output?

- [ ] 350 mV
- [ ] 5 mV
- [x] About 1.25 mV
- [ ] About 0.35 mV

::: reveal
ΔR/R = Gε = 2 × 500 × 10⁻⁶ = 0.001, so ΔR = 0.35 Ω. The quarter bridge gives about V(ΔR/R)/4 = 1.25 mV (exactly 1.2494 mV). Four active gauges in a full bridge would give 5 mV.
:::
:::

::: nameit
## Potentiometers

A potentiometer whose wiper moves with a displacement divides its excitation in proportion, $V_o/V = x$ for a fraction x of travel. A load $R_L$ on the wiper of a pot with total resistance $R_p$ pulls the output down:

$$\frac{V_o}{V} = \frac{x}{1 + (R_p/R_L)x(1 - x)}$$

with the largest error near mid-travel.

## Strain gauges

A conductor stretched by strain ε = ΔL/L changes resistance by $\Delta R/R = G\varepsilon$. Metal foil gauges have a **gauge factor** G ≈ 2 (from the change in geometry plus a little piezoresistance); silicon gauges reach 100 or more, with a large temperature sensitivity.

## The Wheatstone bridge

With equal arms R excited by V, one active arm R + ΔR gives exactly $V_o = V\frac{x}{2(2 + x)} \approx \frac{V}{4}x$ for x = ΔR/R. Two active arms changing in opposite senses on the same side (a **half bridge**) give $Vx/2$, and four (a **full bridge**, two in tension and two in compression) give $Vx$, both exactly linear.

## Temperature

A gauge's resistance also changes with temperature, by $\alpha\Delta T$ in fractional terms, which looks like an apparent strain $\alpha\Delta T/G$. Gauges in adjacent bridge arms see the same temperature, and their changes cancel in the output while opposite strains add, so half and full bridges are temperature-compensated.
:::

::: example
## Compare the quarter-bridge output above with a full bridge of silicon gauges (G = 100) at the same strain and excitation.

::: solution
1. **Foil quarter bridge.** From above, it gives
   $$V_o = 1.249\ \text{mV}$$
2. **Silicon gauges' resistance change.**
   $$\begin{aligned} \frac{\Delta R}{R} &= 100 \times 500 \times 10^{-6} \\ &= 0.05 \end{aligned}$$
3. **Full-bridge output.**
   $$\begin{aligned} V_o &= 5\ \text{V} \times 0.05 \\ &= 250\ \text{mV} \end{aligned}$$
   two hundred times more.
4. **Why it matters.** That's why disposable blood-pressure transducers use diffused silicon bridges.

**Answer:** the silicon full bridge gives 250 mV, two hundred times the foil quarter bridge's 1.249 mV.
:::
:::

::: example
## A 10 kΩ potentiometer at mid-travel drives a 100 kΩ load. What's its error? And what apparent strain does a 1 °C change cause in a foil gauge with α = 20 ppm/°C and G = 2?

::: solution
1. **Loaded potentiometer.** At mid-travel:
   $$\begin{aligned} \frac{V_o}{V} &= \frac{0.5}{1 + 0.1 \times 0.25} \\ &= 0.4878 \end{aligned}$$
2. **Its error.** Against the unloaded 0.5, that's an error of 1.22% of full scale.
3. **Apparent strain from temperature.**
   $$\begin{aligned} \epsilon &= \frac{20 \times 10^{-6}}{2} \\ &= 10\ \text{microstrain/°C} \end{aligned}$$
4. **How much it matters.** That's comparable to a real signal, unless a compensating gauge in an adjacent arm cancels it.

**Answer:** the potentiometer reads 0.4878 of the supply, an error of 1.22% of full scale, and the gauge shows 10 microstrain of apparent strain per °C.
:::
:::

::: example
## A 120 Ω foil gauge (G = 2) sits at the end of leads with 0.5 Ω in each wire, wired as a two-wire quarter bridge. How much do the leads desensitize it, and what apparent strain appears if the copper leads warm by 10 °C (α = 0.0039/°C)?

::: solution
1. **Desensitization.** The 1 Ω of lead resistance in series with the gauge dilutes its change by the factor
   $$\frac{120}{121}$$
   so the sensitivity falls by 0.8%.
2. **Lead resistance change.** Warming the leads by 10 °C raises their resistance by
   $$\begin{aligned} \Delta R &= 1 \times 0.0039 \times 10 \\ &= 0.039\ \Omega \end{aligned}$$
   which the bridge can't tell from strain.
3. **Apparent strain.**
   $$\begin{aligned} \epsilon &= \frac{\Delta R}{RG} \\ &= \frac{0.039}{240} \\ &= 162\ \text{microstrain} \end{aligned}$$
   a large error for a sensor that may be measuring a few hundred.
4. **The cure.** A three-wire connection puts one lead in the gauge's arm and one in the adjacent arm, so their changes cancel.

**Answer:** the leads cut the sensitivity by 0.8%, and warming them by 10 °C shows up as 162 microstrain of apparent strain.
:::
:::

::: check
given: G = 2 | 2.1 | 120; e = 200 | 800 | 2000; R = 120 | 350 | 1000
answer: G*e*1e-6*R
unit: Ω
tolerance: 0.5%

## A {R} Ω strain gauge with gauge factor {G} is strained by {e} microstrain. By how much does its resistance change?

::: right
Right. $G\varepsilon R$ = {answer} Ω.
:::

::: misses
- [G*e*R] Microstrain means $10^{-6}$.
- [any] Not yet. $\Delta R = G\varepsilon R$.
:::
:::

::: check
given: G = 2 | 2.1; e = 200 | 800 | 2000; V = 2.5 | 5 | 10
answer: V*G*e*1e-6/4*1000
unit: mV
tolerance: 0.5%

## A single active gauge (G = {G}) in a bridge excited at {V} V sees {e} microstrain. About what output does the bridge give?

::: right
Right. $VG\varepsilon/4$ = {answer} mV.
:::

::: misses
- [V*G*e*1e-6*1000] That's a full bridge; one active arm gives a quarter.
- [any] Not yet. Quarter-bridge output.
:::
:::

::: check
given: x = 0.02 | 0.05 | 0.1; V = 2.5 | 5 | 10
answer: V*x/(2*(2 + x))*1000
unit: mV
tolerance: 0.05%

## A quarter bridge excited at {V} V has its active arm changed by ΔR/R = {x}. What's the exact output?

::: right
Right. $Vx/(2(2 + x))$ = {answer} mV.
:::

::: misses
- [V*x/4*1000] That's the linear approximation; at this x it's noticeably high.
- [any] Not yet. Solve the two dividers exactly.
:::
:::

::: check
given: G = 2 | 100; e = 300 | 1000; V = 3 | 5 | 10; k = 2 | 4
answer: V*G*e*1e-6*k/4*1000
unit: mV
tolerance: 0.5%

## A bridge excited at {V} V has {k} active gauges (G = {G}) at ±{e} microstrain, arranged so their outputs add. What's its output?

::: right
Right. $V(k/4)G\varepsilon$ = {answer} mV.
:::

::: misses
- [V*G*e*1e-6/4*1000] Count every active arm.
- [any] Not yet. Each active arm adds a quarter-bridge output.
:::
:::

::: check
given: a = 10 | 20 | 50; G = 2 | 2.1; T = 1 | 5 | 10
answer: a*T/G
tolerance: 0.5%

## An uncompensated foil gauge (G = {G}) has a temperature coefficient of {a} ppm/°C. What apparent strain, in microstrain, does a {T} °C change produce?

::: right
Right. $\alpha\Delta T/G$ = {answer} microstrain.
:::

::: misses
- [a*T] Divide by the gauge factor to convert resistance change to strain.
- [any] Not yet. Fractional resistance change over G.
:::
:::

::: check
given: x = 0.25 | 0.5 | 0.75; p = 1 | 10; L = 20 | 100
answer: x/(1 + p/L*x*(1 - x))
tolerance: 0.05%

## A {p} kΩ potentiometer at fraction {x} of its travel drives a {L} kΩ load. What fraction of the excitation appears at the wiper?

::: right
Right. $x/(1 + (R_p/R_L)x(1 - x))$ = {answer}.
:::

::: misses
- [x] The load pulls the output below x.
- [any] Not yet. The lower part of the pot in parallel with the load.
:::
:::

::: check
kind: parts
given: R = 120 | 350; L = 0.2 | 1 | 3; G = 2 | 2.1; T = 5 | 20

## A {R} Ω gauge (G = {G}) is wired as a two-wire quarter bridge through leads totaling {L} Ω, of copper (α = 0.0039/°C).

::: part
answer: L/(R + L)*100
unit: %
tolerance: 0.5%

### By what percent do the leads reduce its sensitivity?

::: misses
- [any] The leads dilute the gauge's change.
:::
:::

::: part
answer: L*0.0039*T/(R*G)*1e6
unit: microstrain
tolerance: 0.5%

### What apparent strain does a {T} °C rise in lead temperature cause?

::: misses
- [any] $\Delta R_L/(RG)$.
:::
:::
:::

::: check
kind: derivation
vars: V = 1..10, x = 0.0001..0.05

## A quarter bridge excited at V has its active arm changed by a fraction x.

::: step
answer: V*x/(2*(2 + x))

### What is its exact output?
:::

::: step
answer: V*x/4

### What does the linear approximation give?
:::

::: step
answer: x/2

### By what fraction does the approximation overstate the output?
:::

::: right
Right. The quarter bridge's nonlinearity is about half the fractional change, so 0.1% at 2000 microstrain.
:::
:::

::: explain
## How do half and full bridges cancel temperature drift while keeping the strain signal?

::: model
A bridge's output depends on the difference between the fractional changes of adjacent arms. Gauges mounted so that one is stretched and its neighbor compressed change in opposite directions with strain, so their difference is twice either change and the signal adds. A temperature change, though, shifts both gauges' resistances by the same fraction in the same direction, so their difference, and the output, is unaffected. A full bridge pairs every arm this way, doubling the signal again. The same arrangement also removes the quarter bridge's nonlinearity, because the bridge's total resistance on each side stays constant as the gauges change.
:::
:::

::: practice

::: check
given: G = 1.8 | 150; e = 50 | 3000; R = 100 | 5000
answer: G*e*1e-6*R
unit: Ω
tolerance: 0.5%

## ΔR: G = {G}, {e} microstrain, R = {R} Ω?

::: misses
- [any] $G\varepsilon R$.
:::
:::

::: check
given: G = 2 | 100; e = 100 | 1500; V = 1 | 12; k = 1 | 2 | 4
answer: V*G*e*1e-6*k/4*1000
unit: mV
tolerance: 0.5%

## Bridge output: {k} active arms, G = {G}, {e} microstrain, {V} V?

::: misses
- [any] $V(k/4)G\varepsilon$.
:::
:::

::: check
given: x = 0.1 | 0.9; p = 0.5 | 50; L = 5 | 500
answer: x/(1 + p/L*x*(1 - x))
tolerance: 0.05%

## Loaded pot: x = {x}, $R_p$ = {p} kΩ, $R_L$ = {L} kΩ?

::: misses
- [any] $x/(1 + (R_p/R_L)x(1 - x))$.
:::
:::
:::