S16 · Lesson 40 · Microphones
Microphone sensitivity in millivolts per pascal and in dBV, converting between output voltage and sound pressure level, the condenser microphone's bias and gap, self-noise, signal-to-noise ratio and dynamic range, MEMS microphones, and first-order directional patterns with their directivity
A phone has three or four microphones, each a MEMS chip a millimeter across that can hear a whisper and survive a rock concert. Studio microphones are larger condensers with lower noise, and directional microphones reject sound from behind by combining pressure and pressure-gradient sensing. All of them are specified by the same handful of numbers: sensitivity, self-noise, maximum level and pattern, and choosing one, or designing the preamp after it, is a calculation in decibels.
- First-order directional patterns , drawn as polar plots: omnidirectional (B = 0), cardioid (0.5), supercardioid (about 0.63), hypercardioid (0.75) and figure-eight (1).
- More B means a narrower front lobe but a rear lobe; the cardioid alone has a full null at the rear.
- The directivity index says how much more the microphone favors the front over diffuse sound from all directions.
Predict
A MEMS microphone is rated −38 dBV/Pa. What voltage does it produce in an 80 dB SPL sound?
−38 dBV/Pa is = 12.6 mV per pascal. 80 dB SPL is 20 µPa × 10⁴ = 0.2 Pa, so the output is 12.6 × 0.2 = 2.5 mV RMS: small, which is why microphone preamplifiers need low noise and plenty of gain.
Name it
Sensitivity
A microphone's sensitivity S is its open-circuit output voltage per pascal, often given in dBV relative to 1 V/Pa: . The output for a sound of level L is
and conversely dB SPL, since 1 Pa is 94 dB.
The condenser microphone
A thin diaphragm a gap d from a fixed backplate, charged to a bias voltage (or by an electret), forms a capacitor whose charge stays constant at audio frequencies. A diaphragm displacement ξ changes the voltage by , so the sensitivity is times the displacement per pascal over d. Higher bias, a more compliant diaphragm or a smaller gap give more output; the gap's air stiffness and the diaphragm's tension set the resonance that limits the bandwidth.
Noise and dynamic range
Self-noise is the SPL that would produce the microphone's own output noise, usually A-weighted: 5 to 20 dB(A) for studio condensers, 25 to 35 dB(A) for MEMS parts. The signal-to-noise ratio is quoted at 94 dB SPL: SNR = 94 − self-noise. The dynamic range runs from the self-noise to the maximum SPL (often the 1% or 10% distortion point).
Directional patterns
An omnidirectional microphone senses pressure. Combining pressure with pressure gradient (velocity) sensing gives . For diffuse sound such a pattern responds with energy relative to omni, so its directivity index is : 4.8 dB for a cardioid, 6.0 dB for a hypercardioid, the most possible for a first-order pattern.
Worked example
What dBV rating is 12.6 mV/Pa? A microphone of that sensitivity reads 5 mV: what's the SPL? What sensitivity does a condenser with 200 V bias, a 20 µm gap and 2 nm/Pa of diaphragm movement have?
Show the solution
- Sensitivity in dBV.
- SPL for 5 mV.
- Condenser sensitivity.
Answer 12.6 mV/Pa is −38.0 dBV/Pa, a 5 mV reading is 86.0 dB SPL, and the condenser's sensitivity is 20 mV/Pa.
Worked example
A cardioid microphone faces a talker. How much does it attenuate sound from 90° and from 180°? What's its directivity index?
Show the solution
- At 90°. or −6 dB.
- At 180°. a full null.
- Directivity index. Diffuse room noise is picked up at a third of an omni's energy.
Answer 6 dB down at 90°, a full null at 180°, and a directivity index of 4.8 dB.
Worked example
A 10 mV/Pa microphone feeds a preamplifier with 2 nV/√Hz of input noise. What equivalent sound level does the preamp's noise represent over 20 Hz to 20 kHz?
Show the solution
- Preamp noise. Over the 19,980 Hz band:
- As a sound pressure. At 10 mV/Pa that corresponds to which is 3.0 dB SPL, unweighted.
- Compare with the microphone. That's far below a good condenser microphone's own self-noise of 10 to 20 dB(A), so this preamp adds almost nothing.
- A dynamic microphone. A 1 mV/Pa dynamic microphone would see the same noise as 23 dB SPL, where the preamp starts to matter.
Answer the preamp's noise is equivalent to 3.0 dB SPL, unweighted.
Check
A microphone's sensitivity is 12.6 mV/Pa. What's that in dBV re 1 V/Pa?
Check
A −38 dBV/Pa microphone is in a 60 dB SPL sound. What RMS voltage does it produce?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A 12.6 mV/Pa microphone outputs 0.5 mV. What's the SPL?
Check
A condenser microphone has 48 V of bias across a 25 µm gap, and its diaphragm moves 1 nm per pascal. What's its sensitivity, in mV per pascal?
Write units the way you normally would: 1.5 mV/Pa, 1500 µV/Pa and 0.0015 V/Pa are the same answer.
Check
A microphone has 26 dB(A) of self-noise and a maximum SPL of 110 dB. What's its dynamic range?
Check
A first-order microphone has the pattern (1 − B) + B cos θ with B = 0.5. What's its directivity index?
Check
A 1 mV/Pa microphone feeds a preamplifier with 3 nV/√Hz of input noise, over 20 Hz to 20 kHz.
(a)
How much noise does the preamp add?
Write units the way you normally would: 1.5 µV, 1500 nV and 0.0015 mV are the same answer.
(b)
What equivalent sound pressure level is that?
Check
A microphone has sensitivity S (mV/Pa) and outputs V volts RMS.
Step 1
What is its sensitivity in dBV re 1 V/Pa?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What sound pressure level is it measuring?
Explain why
How does a cardioid microphone reject sound from behind?
A pressure microphone responds equally to sound from every direction, because pressure has no direction. A pressure-gradient microphone, open on both sides of its diaphragm, responds to the difference in pressure across it, which is largest for sound arriving along its axis and zero from the side, with opposite polarity front and back: a figure-eight. Adding equal parts of the two, either electrically or with an acoustic delay path behind the diaphragm, makes sound from the front add in phase and sound from the rear cancel exactly, because there the gradient's polarity is reversed. The result is the heart-shaped cardioid, with full sensitivity at the front, half at the sides and a null at the back.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.