title: Acoustic filters and mufflers
heading: Sound in ducts treated as transmission lines, the expansion-chamber muffler and its transmission loss, the area ratio and length that set its peaks and pass bands, side-branch resonators that notch out a frequency, and the effect of hot exhaust gas
eyebrow: S16 · Lesson 25 · Acoustic filters and mufflers
xp: 50
---

::: hook
An engine's exhaust carries loud pulses at the firing frequency and its harmonics, and the muffler's job is to stop them while still letting the gas flow freely. A reactive muffler does it without absorbing anything: abrupt changes in the pipe's cross-section reflect sound back toward the engine, just as impedance steps reflect signals on a transmission line (C10). The simplest one, a single expansion chamber, works beautifully at some frequencies and not at all at others, and seeing why is a lesson in standing waves.
:::

::: play
- Transmission loss of an expansion chamber of length L whose area is m times the pipe's: $TL = 10\log[1 + \frac{1}{4}(m - 1/m)^2\sin^2kL]$.
- It peaks where the chamber is a quarter wavelength long, $f = c/4L$ (and odd multiples), at $10\log[1 + \frac{1}{4}(m - 1/m)^2]$.
- It falls to zero where the chamber is a whole number of half wavelengths, $f = nc/2L$: there the chamber is acoustically invisible.
:::

```sim plot
view: graph
x: f = 20..2000 log
y: T = 0..40
slider: m = 2..50 step 1 = 16
slider: L = 0.1..1.5 step 0.05 = 0.5
plot: 10*log(1 + 0.25*(m - 1/m)^2*sin(2*pi*f*L/343)^2) | samples: 600 | label: transmission loss, dB
readout: peak loss, dB = 10*log(1 + 0.25*(m - 1/m)^2) | digits: 3
readout: first peak, Hz = 343/(4*L) | digits: 4
readout: first pass frequency, Hz = 343/(2*L) | digits: 4
```

::: predict
## A 5 cm exhaust pipe opens into a chamber 20 cm in diameter and 0.5 m long. What's the most transmission loss it can give?

- [ ] 6 dB
- [x] About 18 dB
- [ ] About 32 dB
- [ ] Unlimited

::: reveal
The area ratio is (20/5)² = 16, so the peak is 10 log[1 + ¼(16 − 1/16)²] = 18.1 dB, reached at 171.5 Hz in cool air (where 0.5 m is a quarter wavelength). At 343 Hz the loss drops to zero, so practical mufflers combine chambers of different lengths, internal tubes and absorbent packing.
:::
:::

::: nameit
## Ducts as transmission lines

Below the first cross mode (lesson 27), sound in a duct travels as plane waves, and a duct of area S has a characteristic acoustic impedance $\rho_0c/S$ (pressure over volume velocity). An abrupt area change is an impedance step, and chambers and pipes are transmission-line sections, exactly C10's mathematics.

## The expansion chamber

A chamber of area $S_2$ and length L between pipes of area $S_1$, with area ratio $m = S_2/S_1$ and anechoic termination, gives

$$TL = 10\log_{10}\left[1 + \frac{1}{4}\left(m - \frac{1}{m}\right)^2\sin^2kL\right]$$

- Peaks at $kL = \pi/2, 3\pi/2, \ldots$ (f = c/4L, 3c/4L, …) of height $10\log[1 + \frac{1}{4}(m - 1/m)^2]$, set by the area ratio.
- Zeros at $kL = n\pi$ (f = nc/2L), where the chamber is half-wave transparent.

## Side-branch resonators

A Helmholtz resonator (lesson 24) teed into the duct presents near-zero impedance at its resonance, shorting out the sound there: a notch filter for a particular tone, such as a fan's blade-pass frequency or an engine's firing frequency.

## Hot gas

Exhaust gas is hot, so c is higher (about 480 m/s at 300 °C) and all the frequencies scale up by c/343: a muffler designed in cool air misses its target when the gas heats up.
:::

::: example
## What does the predict question's chamber give at 100 Hz in cool air, and where does its peak move with exhaust at 300 °C?

::: solution
1. **kL at 100 Hz.**
   $$\begin{aligned} kL &= 2\pi \times 100 \times 0.5/343 \\ &= 0.916 \end{aligned}$$
   so $\sin^2 kL$ = 0.629.
2. **Transmission loss.**
   $$\begin{aligned} \text{TL} &= 10\log(1 + 63.5 \times 0.629) \\ &= 16.1\ \text{dB} \end{aligned}$$
3. **Speed of sound at 300 °C.**
   $$\begin{aligned} c &= 331.3\sqrt{1 + 300/273.15} \\ &= 480\ \text{m/s} \end{aligned}$$
4. **The new peak.**
   $$\begin{aligned} f &= 480/(4 \times 0.5) \\ &= 240\ \text{Hz} \end{aligned}$$

**Answer:** 16.1 dB at 100 Hz, and in the 300 °C exhaust the first peak moves to 240 Hz.
:::
:::

::: example
## A pipe of 4 cm diameter opens into a 16 cm chamber. What's the area ratio and peak loss? How long must the chamber be to peak at 120 Hz in 400 m/s gas?

::: solution
1. **Area ratio.**
   $$\begin{aligned} m &= (16/4)^2 \\ &= 16 \end{aligned}$$
   again, so the peak is 18.1 dB.
2. **Chamber length.** A quarter wavelength at 120 Hz in 400 m/s gas is
   $$\begin{aligned} L &= 400/(4 \times 120) \\ &= 0.833\ \text{m} \end{aligned}$$

**Answer:** an area ratio of 16 with an 18.1 dB peak, and a chamber 0.833 m long.
:::
:::

::: example
## A quarter-wave side branch must cancel 125 Hz in a duct. How long should it be in air at 20 °C, and in exhaust at 300 °C?

::: solution
1. **How the branch works.** A closed side branch a quarter wavelength long presents zero impedance at its opening at that frequency, shorting the duct's pressure.
2. **Length in air.**
   $$\begin{aligned} L &= c/4f \\ &= 343/500 \\ &= 0.686\ \text{m} \end{aligned}$$
3. **Length in hot exhaust.** At 300 °C the speed of sound is
   $$\begin{aligned} c &= 331.3\sqrt{1 + 300/273.15} \\ &= 480\ \text{m/s} \end{aligned}$$
   so the branch must be 0.96 m.
4. **Its limits.** Its attenuation is narrow-band, so it suits engines and fans with a steady tone, and it must be retuned if the gas temperature changes.

**Answer:** 0.686 m in air at 20 °C and 0.96 m in exhaust at 300 °C.
:::
:::

::: check
given: m = 4 | 16 | 36; L = 0.3 | 0.6; f = 80 | 200
answer: 10*log(1 + 0.25*(m - 1/m)^2*sin(2*pi*f*L/343)^2)
unit: dB
tolerance: 0.5%

## An expansion chamber of length {L} m has {m} times the pipe's area. What's its transmission loss at {f} Hz in air?

::: right
Right. $10\log[1 + \frac{1}{4}(m - 1/m)^2\sin^2kL]$ = {answer} dB.
:::

::: misses
- [10*log(1 + 0.25*(m - 1/m)^2)] That's the peak; at this frequency include $\sin^2kL$.
- [any] Not yet. Evaluate kL first.
:::
:::

::: check
given: a = 2 | 4 | 5; b = 10 | 16 | 25
answer: 10*log(1 + 0.25*((b/a)^2 - (a/b)^2)^2)
unit: dB
tolerance: 0.5%

## A pipe of {a} cm diameter opens into a chamber of {b} cm diameter. What's the chamber's peak transmission loss?

::: right
Right. With m = (b/a)², {answer} dB.
:::

::: misses
- [10*log(1 + 0.25*(b/a - a/b)^2)] The area ratio is the diameter ratio squared.
- [any] Not yet. Find m, then the peak formula.
:::
:::

::: check
given: L = 0.25 | 0.5 | 1; c = 343 | 480
answer: c/(4*L)
unit: Hz
tolerance: 0.5%

## At what frequency does an expansion chamber {L} m long first reach its peak loss, in gas where c = {c} m/s?

::: right
Right. $c/4L$ = {answer} Hz.
:::

::: misses
- [c/(2*L)] That's where the loss falls to zero.
- [any] Not yet. Where the chamber is a quarter wavelength long.
:::
:::

::: check
given: L = 0.25 | 0.5 | 1; c = 343 | 480
answer: c/(2*L)
unit: Hz
tolerance: 0.5%

## At what frequency does a {L} m chamber first pass sound with no loss (c = {c} m/s)?

::: right
Right. $c/2L$ = {answer} Hz.
:::

::: misses
- [c/(4*L)] That's the peak; zeros fall where the chamber is half a wavelength.
- [any] Not yet. Where sin kL = 0.
:::
:::

::: check
given: f = 60 | 120 | 250; c = 343 | 450
answer: c/(4*f)
unit: m
tolerance: 0.5%

## How long should an expansion chamber be to put its first peak at {f} Hz, with c = {c} m/s?

::: right
Right. $c/4f$ = {answer} m.
:::

::: misses
- [c/(2*f)] A quarter wavelength, not a half.
- [any] Not yet. L = λ/4.
:::
:::

::: check
given: T = 100 | 300 | 500
answer: 331.3*sqrt(1 + T/273.15)/343
tolerance: 0.5%

## By what factor do a muffler's peak frequencies rise when the gas is at {T} °C instead of 20 °C?

::: right
Right. $c(T)/343$ = {answer}.
:::

::: misses
- [(273.15 + T)/293.15] The speed of sound goes as the square root of absolute temperature.
- [any] Not yet. Ratio of sound speeds.
:::
:::

::: check
kind: parts
given: f = 60 | 125 | 400; T = 20 | 150 | 400

## A quarter-wave side branch must cancel {f} Hz in gas at {T} °C (c = 331.3√(1 + T/273.15) m/s).

::: part
answer: 331.3*sqrt(1 + T/273.15)
unit: m/s
tolerance: 0.5%

### What is the speed of sound?

::: misses
- [any] $331.3\sqrt{1 + T/273.15}$.
:::
:::

::: part
answer: 331.3*sqrt(1 + T/273.15)/(4*f)
unit: m
tolerance: 0.5%

### How long should the branch be?

::: misses
- [331.3*sqrt(1 + T/273.15)/(2*f)] A closed branch cancels at a quarter wavelength.
- [any] c/4f.
:::
:::
:::

::: check
kind: derivation
vars: m = 1.5..50, k = 0..20, L = 0.05..2

## An expansion chamber of length L has area ratio m; sound of wavenumber k passes through it.

::: step
answer: 10*log(1 + 0.25*(m - 1/m)^2*sin(k*L)^2)

### What is its transmission loss?
:::

::: step
answer: 10*log(1 + 0.25*(m - 1/m)^2)

### What is the peak loss?
:::

::: right
Right. Peaks fall where kL is an odd multiple of π/2; at multiples of π the chamber passes sound freely.
:::
:::

::: explain
## How does a reactive muffler reduce noise without absorbing it?

::: model
At each sudden change of area the duct's acoustic impedance jumps, so part of the incoming wave reflects back toward the source. A chamber has two such steps, and the waves reflected from them and bouncing inside interfere. When the chamber is a quarter wavelength long, the reflections combine to send as much as possible back upstream and the transmitted wave is weakest; when it's a half wavelength, the reflections cancel and the chamber passes sound freely. The energy goes back toward the engine, where it changes how the source radiates, and none of it is absorbed; to make the loss broadband, mufflers combine several chambers, perforated tubes and sometimes absorbent packing.
:::
:::

::: practice

::: check
given: m = 2 | 60; L = 0.1 | 1.5; f = 30 | 1000
answer: 10*log(1 + 0.25*(m - 1/m)^2*sin(2*pi*f*L/343)^2)
unit: dB
tolerance: 0.5%

## Chamber TL: m = {m}, L = {L} m, {f} Hz?

::: misses
- [any] The expansion-chamber formula.
:::
:::

::: check
given: a = 1 | 8; b = 9 | 40
answer: 10*log(1 + 0.25*((b/a)^2 - (a/b)^2)^2)
unit: dB
tolerance: 0.5%

## Peak TL: {a} cm pipe into {b} cm chamber?

::: misses
- [any] m = (b/a)².
:::
:::

::: check
given: f = 30 | 800; c = 340 | 520
answer: c/(4*f)
unit: m
tolerance: 0.5%

## Chamber length for a peak at {f} Hz, c = {c}?

::: misses
- [any] c/4f.
:::
:::
:::