S16 · Lesson 30 · Noise exposure and hearing protection
Equivalent continuous level for sounds that vary in time, daily exposure normalized to eight hours, the NIOSH and OSHA criteria with their exchange rates, noise dose from several exposures, hearing protector ratings and their derating, and community noise with a night penalty
Noise-induced hearing loss is permanent and entirely preventable, and it depends on dose: how loud, for how long. A worker can spend eight hours at 85 dB(A) by the NIOSH criterion, but only one hour at 94 dB(A), because every 3 dB doubles the sound energy. Exposure rules, dosimeters and hearing-protector ratings all reduce to the same decibel arithmetic as lesson 8, applied to energy accumulated over time.
- Permitted daily exposure time against A-weighted level under two criteria: NIOSH (85 dB(A) for 8 hours, halving the time every 3 dB) and the OSHA regulation (90 dB(A) for 8 hours, halving every 5 dB).
- The 3 dB exchange rate follows equal energy; OSHA's 5 dB rate allows much longer exposures at high levels.
- At 100 dB(A), NIOSH allows 15 minutes and OSHA 2 hours.
Predict
A worker spends 2 h at 85 dB(A), 4 h at 88 dB(A) and 2 h at 75 dB(A). What's the 8-hour equivalent level?
Average the energy, not the decibels: = 86.0 dB(A). The four hours at 88 dB(A) carry most of the energy. By NIOSH's criterion that's a dose of 127%: over the limit.
Name it
Equivalent continuous level
A level that varies in time is summarized by the steady level with the same energy:
Normalized to an 8-hour day, the daily exposure is .
Exposure criteria
- NIOSH recommends 85 dB(A) for 8 hours with a 3 dB exchange rate: hours.
- The OSHA regulation in the United States permits 90 dB(A) for 8 hours with a 5 dB exchange rate, , and requires a hearing conservation program from 85 dB(A).
The dose from several exposures adds the fractions of each allowance used:
with the time spent at level . Over 100% exceeds the criterion.
Hearing protectors
Protectors carry a noise reduction rating (NRR), measured in ideal laboratory fittings. For an A-weighted exposure, OSHA's derating estimates the real protection as (NRR − 7)/2 dB: an NRR 29 earplug gives about 11 dB in practice.
Community noise
Environmental noise is often described by the day–night level , the 24-hour with 10 dB added to levels between 10 p.m. and 7 a.m., reflecting how much more disturbing noise is at night.
Worked example
How long may a worker stay at 94 dB(A) under each criterion? What's the daily exposure for 2 hours at 92 dB(A) and quiet otherwise?
Show the solution
- NIOSH limit.
- OSHA limit.
- Daily exposure. Two hours at 92 dB(A) gives still over NIOSH's 85.
Answer 1 hour under NIOSH and 4.6 hours under OSHA; 2 hours at 92 dB(A) is a daily exposure of 86.0 dB(A).
Worked example
A worker in 100 dB(A) wears earplugs rated NRR 29. What's the estimated protected level?
Show the solution
- Derate the NRR. The real protection is about
- Protected level.
- Is it enough? It's still above 85, so the worker needs better-fitted plugs, earmuffs over plugs, or less time there.
Answer about 89 dB(A), still above 85.
Worked example
A worker spends one hour at 100 dB(A) and is otherwise in quiet. What's the daily dose under NIOSH's criterion and under OSHA's regulation?
Show the solution
- NIOSH's allowed time. NIOSH allows 8 hours at 85 dB(A), halving for every 3 dB: so one hour is a 400% dose.
- OSHA's allowed time. OSHA allows 8 hours at 90 dB(A), halving every 5 dB: so the same hour is a 50% dose.
- Why they differ. The criteria differ by a factor of eight here; NIOSH's 3 dB exchange rate follows the equal-energy principle, which treats hearing damage as proportional to the sound energy received.
Answer a 400% dose under NIOSH and a 50% dose under OSHA.
Check
A worker spends 3 h at 88 dB(A) and the rest of an 8-hour shift at 80 dB(A). What's the shift's equivalent level?
Check
Under NIOSH's criterion, how long may a worker be exposed to 94 dB(A) per day?
Check
Under the OSHA regulation, how long may a worker be exposed to 95 dB(A) per day?
Check
A worker spends 1 h at 91 dB(A) and 2 h at 97 dB(A). What's the NIOSH dose in percent?
Check
A worker's only noise is 0.5 h at 95 dB(A). What's the daily exposure normalized to 8 hours?
Check
A worker in 100 dB(A) wears hearing protection rated NRR 21. Using OSHA's derating, what's the estimated protected level?
Check
A worker spends 0.5 h at 97 dB(A) and is otherwise in quiet.
(a)
What is the NIOSH dose?
(b)
What is the OSHA dose?
Check
A worker spends t hours at a dB(A) and the rest of an 8-hour shift at b dB(A).
Step 1
What is the 8-hour equivalent level?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
How long does NIOSH allow at a dB(A)?
Explain why
Why does NIOSH halve the allowed exposure time for every 3 dB increase in level?
The 3 dB exchange rate follows from the equal-energy hypothesis: hearing damage depends on the total sound energy received, the product of intensity and time. A 3 dB increase doubles the intensity, so keeping the energy the same requires halving the time. Evidence from studies of exposed workers supports equal energy as a reasonable predictor of risk. The OSHA regulation's 5 dB rate assumes that real exposures are intermittent and that the ear recovers between loud periods, which lets long exposures to high levels count as acceptable; at 100 dB(A) it allows eight times longer than NIOSH does.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.