title: Noise exposure and hearing protection
heading: Equivalent continuous level for sounds that vary in time, daily exposure normalized to eight hours, the NIOSH and OSHA criteria with their exchange rates, noise dose from several exposures, hearing protector ratings and their derating, and community noise with a night penalty
eyebrow: S16 · Lesson 30 · Noise exposure and hearing protection
xp: 50
---

::: hook
Noise-induced hearing loss is permanent and entirely preventable, and it depends on dose: how loud, for how long. A worker can spend eight hours at 85 dB(A) by the NIOSH criterion, but only one hour at 94 dB(A), because every 3 dB doubles the sound energy. Exposure rules, dosimeters and hearing-protector ratings all reduce to the same decibel arithmetic as lesson 8, applied to energy accumulated over time.
:::

::: play
- Permitted daily exposure time against A-weighted level under two criteria: NIOSH (85 dB(A) for 8 hours, halving the time every 3 dB) and the OSHA regulation (90 dB(A) for 8 hours, halving every 5 dB).
- The 3 dB exchange rate follows equal energy; OSHA's 5 dB rate allows much longer exposures at high levels.
- At 100 dB(A), NIOSH allows 15 minutes and OSHA 2 hours.
:::

```sim plot
view: graph
x: L = 80..115
y: T = 0.01..32 log
plot: 8/2^((L - 85)/3) | samples: 300 | label: NIOSH limit, hours
plot: 8/2^((L - 90)/5) | samples: 300 | color: ch3 | label: OSHA limit, hours
```

::: predict
## A worker spends 2 h at 85 dB(A), 4 h at 88 dB(A) and 2 h at 75 dB(A). What's the 8-hour equivalent level?

- [ ] 82.7 dB(A)
- [ ] 88 dB(A)
- [x] About 86 dB(A)
- [ ] About 92 dB(A)

::: reveal
Average the energy, not the decibels: $10\log[(2 \times 10^{8.5} + 4 \times 10^{8.8} + 2 \times 10^{7.5})/8]$ = 86.0 dB(A). The four hours at 88 dB(A) carry most of the energy. By NIOSH's criterion that's a dose of 127%: over the limit.
:::
:::

::: nameit
## Equivalent continuous level

A level that varies in time is summarized by the steady level with the same energy:

$$L_{eq} = 10\log_{10}\left[\frac{1}{T}\sum_it_i10^{L_i/10}\right]$$

Normalized to an 8-hour day, the daily exposure is $L_{EX,8h} = L_{eq,T} + 10\log_{10}(T/8\text{ h})$.

## Exposure criteria

- **NIOSH** recommends 85 dB(A) for 8 hours with a **3 dB exchange rate**: $T = 8/2^{(L - 85)/3}$ hours.
- The **OSHA** regulation in the United States permits 90 dB(A) for 8 hours with a 5 dB exchange rate, $T = 8/2^{(L - 90)/5}$, and requires a hearing conservation program from 85 dB(A).

The **dose** from several exposures adds the fractions of each allowance used:

$$D = 100\%\sum_i\frac{C_i}{T_i}$$

with $C_i$ the time spent at level $L_i$. Over 100% exceeds the criterion.

## Hearing protectors

Protectors carry a noise reduction rating (NRR), measured in ideal laboratory fittings. For an A-weighted exposure, OSHA's derating estimates the real protection as (NRR − 7)/2 dB: an NRR 29 earplug gives about 11 dB in practice.

## Community noise

Environmental noise is often described by the day–night level $L_{dn}$, the 24-hour $L_{eq}$ with 10 dB added to levels between 10 p.m. and 7 a.m., reflecting how much more disturbing noise is at night.
:::

::: example
## How long may a worker stay at 94 dB(A) under each criterion? What's the daily exposure for 2 hours at 92 dB(A) and quiet otherwise?

::: solution
1. **NIOSH limit.**
   $$\begin{aligned} T &= 8/2^{(94 - 85)/3} \\ &= 1\ \text{h} \end{aligned}$$
2. **OSHA limit.**
   $$\begin{aligned} T &= 8/2^{(94 - 90)/5} \\ &= 4.6\ \text{h} \end{aligned}$$
3. **Daily exposure.** Two hours at 92 dB(A) gives
   $$\begin{aligned} L_{EX,8h} &= 92 + 10\log(2/8) \\ &= 86.0\ \text{dB(A)} \end{aligned}$$
   still over NIOSH's 85.

**Answer:** 1 hour under NIOSH and 4.6 hours under OSHA; 2 hours at 92 dB(A) is a daily exposure of 86.0 dB(A).
:::
:::

::: example
## A worker in 100 dB(A) wears earplugs rated NRR 29. What's the estimated protected level?

::: solution
1. **Derate the NRR.** The real protection is about
   $$(29 - 7)/2 = 11\ \text{dB}$$
2. **Protected level.**
   $$100 - 11 = 89\ \text{dB(A)}$$
3. **Is it enough?** It's still above 85, so the worker needs better-fitted plugs, earmuffs over plugs, or less time there.

**Answer:** about 89 dB(A), still above 85.
:::
:::

::: example
## A worker spends one hour at 100 dB(A) and is otherwise in quiet. What's the daily dose under NIOSH's criterion and under OSHA's regulation?

::: solution
1. **NIOSH's allowed time.** NIOSH allows 8 hours at 85 dB(A), halving for every 3 dB:
   $$\begin{aligned} T &= 8/2^{15/3} \\ &= 0.25\ \text{h} \end{aligned}$$
   so one hour is a 400% dose.
2. **OSHA's allowed time.** OSHA allows 8 hours at 90 dB(A), halving every 5 dB:
   $$\begin{aligned} T &= 8/2^{10/5} \\ &= 2\ \text{h} \end{aligned}$$
   so the same hour is a 50% dose.
3. **Why they differ.** The criteria differ by a factor of eight here; NIOSH's 3 dB exchange rate follows the equal-energy principle, which treats hearing damage as proportional to the sound energy received.

**Answer:** a 400% dose under NIOSH and a 50% dose under OSHA.
:::
:::

::: check
given: a = 80 | 86; b = 88 | 94; t = 1 | 3
answer: 10*log((t*10^(b/10) + (8 - t)*10^(a/10))/8)
unit: dB
tolerance: 0.1%

## A worker spends {t} h at {b} dB(A) and the rest of an 8-hour shift at {a} dB(A). What's the shift's equivalent level?

::: right
Right. Energy average: {answer} dB(A).
:::

::: misses
- [any] Not yet. Time-weight the intensities.
:::
:::

::: check
given: L = 88 | 94 | 100 | 106
answer: 8/2^((L - 85)/3)
unit: h
tolerance: 0.5%

## Under NIOSH's criterion, how long may a worker be exposed to {L} dB(A) per day?

::: right
Right. $8/2^{(L - 85)/3}$ = {answer} h.
:::

::: misses
- [8/2^((L - 85)/5)] NIOSH uses a 3 dB exchange rate.
- [any] Not yet. Halve the time for every 3 dB above 85.
:::
:::

::: check
given: L = 92 | 95 | 100 | 105
answer: 8/2^((L - 90)/5)
unit: h
tolerance: 0.5%

## Under the OSHA regulation, how long may a worker be exposed to {L} dB(A) per day?

::: right
Right. $8/2^{(L - 90)/5}$ = {answer} h.
:::

::: misses
- [8/2^((L - 90)/3)] OSHA uses a 5 dB exchange rate.
- [any] Not yet. Halve the time for every 5 dB above 90.
:::
:::

::: check
given: a = 1 | 2; b = 2 | 4; L = 88 | 91; M = 94 | 97
answer: 100*(a/(8/2^((L - 85)/3)) + b/(8/2^((M - 85)/3)))
tolerance: 0.5%

## A worker spends {a} h at {L} dB(A) and {b} h at {M} dB(A). What's the NIOSH dose in percent?

::: right
Right. $100\sum C_i/T_i$ = {answer}%.
:::

::: misses
- [any] Not yet. Divide each time by its allowed time and add.
:::
:::

::: check
given: L = 88 | 95 | 100; t = 0.5 | 2 | 4
answer: L + 10*log(t/8)
unit: dB
tolerance: 0.1%

## A worker's only noise is {t} h at {L} dB(A). What's the daily exposure normalized to 8 hours?

::: right
Right. $L + 10\log(t/8)$ = {answer} dB(A).
:::

::: misses
- [L + 20*log(t/8)] Energy scales with time: 10 log.
- [any] Not yet. Spread the energy over 8 hours.
:::
:::

::: check
given: L = 95 | 100 | 105; N = 21 | 29 | 33
answer: L - (N - 7)/2
unit: dB
tolerance: 0.1%

## A worker in {L} dB(A) wears hearing protection rated NRR {N}. Using OSHA's derating, what's the estimated protected level?

::: right
Right. $L - (\text{NRR} - 7)/2$ = {answer} dB(A).
:::

::: misses
- [L - N] Laboratory ratings overstate real-world protection; derate them.
- [any] Not yet. Subtract (NRR − 7)/2.
:::
:::

::: check
kind: parts
given: L = 91 | 97 | 103; t = 0.5 | 2

## A worker spends {t} h at {L} dB(A) and is otherwise in quiet.

::: part
answer: t/(8/2^((L - 85)/3))*100
unit: %
tolerance: 0.5%

### What is the NIOSH dose?

::: misses
- [t/(8/2^((L - 90)/5))*100] That's OSHA's; NIOSH uses 85 dB(A) and a 3 dB exchange.
- [any] Time over $8/2^{(L - 85)/3}$ hours.
:::
:::

::: part
answer: t/(8/2^((L - 90)/5))*100
unit: %
tolerance: 0.5%

### What is the OSHA dose?

::: misses
- [any] Time over $8/2^{(L - 90)/5}$ hours.
:::
:::
:::

::: check
kind: derivation
vars: a = 70..110, b = 70..110, t = 0..8

## A worker spends t hours at a dB(A) and the rest of an 8-hour shift at b dB(A).

::: step
answer: 10*log((t*10^(a/10) + (8 - t)*10^(b/10))/8)

### What is the 8-hour equivalent level?
:::

::: step
answer: 8/2^((a - 85)/3)

### How long does NIOSH allow at a dB(A)?
:::

::: right
Right. The loudest periods dominate the average, since it adds energy, not decibels.
:::
:::

::: explain
## Why does NIOSH halve the allowed exposure time for every 3 dB increase in level?

::: model
The 3 dB exchange rate follows from the equal-energy hypothesis: hearing damage depends on the total sound energy received, the product of intensity and time. A 3 dB increase doubles the intensity, so keeping the energy the same requires halving the time. Evidence from studies of exposed workers supports equal energy as a reasonable predictor of risk. The OSHA regulation's 5 dB rate assumes that real exposures are intermittent and that the ear recovers between loud periods, which lets long exposures to high levels count as acceptable; at 100 dB(A) it allows eight times longer than NIOSH does.
:::
:::

::: practice

::: check
given: L = 85 | 88 | 91 | 94 | 100 | 106 | 115
answer: 8/2^((L - 85)/3)
unit: h
tolerance: 0.5%

## NIOSH time at {L} dB(A)?

::: misses
- [any] $8/2^{(L - 85)/3}$.
:::
:::

::: check
given: a = 70 | 90; b = 85 | 105; t = 0.25 | 6
answer: 10*log((t*10^(b/10) + (8 - t)*10^(a/10))/8)
unit: dB
tolerance: 0.1%

## Leq: {t} h at {b}, rest of 8 h at {a} dB(A)?

::: misses
- [any] Time-weighted energy average.
:::
:::

::: check
given: L = 80 | 110; t = 0.1 | 12
answer: L + 10*log(t/8)
unit: dB
tolerance: 0.1%

## $L_{EX,8h}$: {t} h at {L} dB(A)?

::: misses
- [any] $L + 10\log(t/8)$.
:::
:::
:::