S16 · Problem set 11
Problem set 11: design problems for mount stiffness, enclosure linings and seals, expansion chambers, Helmholtz absorbers and side branches, reverberation treatment, barrier heights, array spacing, sealed and vented boxes, crossovers, sonar source levels and active-control latency
Each problem here starts from a target, a level, a frequency or a reverberation time, and asks for the dimension or component that meets it. They draw on the whole course, and most are the first calculation an acoustical engineer would make on the job.
Check
A 400 kg machine sits on 6 identical mounts, and the mounted system must have a natural frequency of 4 Hz.
(a)
What stiffness must each mount have?
Write units the way you normally would: 1.5 kN/m, 1500 N/m and 0.0015 MN/m are the same answer.
(b)
How far do they deflect under the machine's weight?
Check
An enclosure must give 20 dB of insertion loss; its walls give 35 dB and its lining an average absorption of 0.8.
(a)
What composite wall loss is needed, leaks included?
(b)
What is the largest open area allowed, as a percentage of the walls?
Check
An expansion chamber must peak at 120 Hz in gas at 20 °C and give 25 dB there.
(a)
How long must it be?
Write units the way you normally would: 1.5 m, 1500 mm and 0.0015 km are the same answer.
(b)
What area ratio must it have?
Check
A Helmholtz absorber with a 0.002 m³ cavity and a neck 2.5 cm in radius must be tuned to 100 Hz (end corrections 1.7a in all).
(a)
What effective neck length does that need?
Write units the way you normally would: 1.5 cm, 15 mm and 0.015 m are the same answer.
(b)
How long must the physical neck be (negative means no neck can tune it this low)?
Check
A room of 2000 m³ has a reverberation time of 1.5 s and must reach 1.2 s with panels of absorption coefficient 0.85 (Sabine).
(a)
How much absorption must be added?
(b)
What area of panels does that take, ignoring the surface they cover?
Check
A barrier must give 15 dB of insertion loss at 250 Hz (Maekawa).
(a)
What Fresnel number does that require?
(b)
What path difference must the barrier add?
Write units the way you normally would: 1.5 m, 1500 mm and 0.0015 km are the same answer.
Check
A line array must steer up to 30° at frequencies up to 3000 Hz, in a medium where c = 1500 m/s.
(a)
What is the largest element spacing without grating lobes?
Write units the way you normally would: 1.5 cm, 15 mm and 0.015 m are the same answer.
Check
A driver with = 80 L, = 0.3 and = 40 Hz goes into a sealed box for = 0.707.
(a)
What box volume does that need?
Write units the way you normally would: 1.5 L and 1500 mL are the same answer.
(b)
Where is the box's resonance?
Check
A 30 L vented box is to be tuned to 25 Hz with a port 10 cm in diameter (end corrections 1.7 × radius in all).
(a)
How long should the port tube be?
Write units the way you normally would: 1.5 cm, 15 mm and 0.015 m are the same answer.
Check
A second-order Linkwitz–Riley crossover at 300 Hz feeds 6 Ω drivers.
(a)
What inductance does each section need?
Write units the way you normally would: 1.5 mH, 1500 µH and 0.0015 H are the same answer.
(b)
What capacitance?
Check
An active sonar must detect a target of strength 30 dB at 10 km at 3 kHz, against 80 dB of noise, with directivity index 10 dB and detection threshold 10 dB.
(a)
What two-way transmission loss does spherical spreading plus Thorp's absorption give?
(b)
What source level does it need?
Check
A duct's anti-noise controller has its reference microphone 1 m upstream of the speaker, samples at 16 kHz, and its converters and speaker take 0.8 ms.
(a)
How many samples of filter delay can it afford and stay causal?
Check
A baffled piston of radius 0.1 m radiates 1000 Hz in air (c = 343 m/s); a design needs a directivity index of 10 dB.
(a)
What is its ka?
(b)
What radius gives 10 dB, using DI ≈ 10 log((ka)²) for large ka?
Write units the way you normally would: 1.5 cm, 15 mm and 0.015 m are the same answer.
Check
Workers face 100 dB(A) all shift and must be brought to 80 dB(A) with hearing protectors, using OSHA's derating of (NRR − 7)/2.
(a)
What noise reduction rating must the protectors carry?
(b)
Without protection, how long may they stay under NIOSH's criterion?
Check
A double wall's first panel is 15 kg/m² and its second 10 kg/m²; its mass–air–mass resonance must be at 100 Hz.
(a)
How deep must the gap be?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
Have paper and a calculator ready. Work each problem out by hand, then enter the answer. Your first try on each one counts toward your score.
Practice
Keep practicing
15 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.