S16 Acoustics · Practice
Problem set 3: isolation, walls, enclosures and waves
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A machine running at 25 Hz sits on mounts deflecting 6 mm under its weight, with damping ratio 0.1.
(a)
What is the natural frequency?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
(b)
What transmissibility results, in decibels?
Check
A machine running at 30 Hz needs 10 dB of isolation from an undamped mount.
(a)
What frequency ratio does that take?
(b)
What static deflection must the mount have?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
Check
A structure with 2000 kg of modal mass resonates at 8 Hz; a tuned absorber of mass ratio 0.02 is added.
(a)
How heavy is the absorber?
Write units the way you normally would: 1.5 kg and 1500 g are the same answer.
(b)
To what frequency should it be tuned?
(c)
What damping ratio should it have?
Check
A machine of 105 dB sound power is enclosed by walls of 35 dB transmission loss with inside absorption 0.03.
(a)
What insertion loss does the enclosure give?
(b)
What sound power level escapes?
Check
A lined enclosure (inside absorption 0.8) has walls of 40 dB with 0.0002 of their area open.
(a)
What composite transmission loss do its walls have?
(b)
What insertion loss does the enclosure give?
Check
A close-fitting cover of 3 kg/m² sits 30 mm from a machine whose strongest tone is 125 Hz.
(a)
Where is its mass–air resonance?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
(b)
What gap would put the resonance at two-thirds of the tone's frequency?
Check
A double wall has panels of 10 and 10 kg/m² with a 100 mm air gap; compare it with one panel of their combined mass at 1000 Hz (normal incidence, ρc = 415 rayl).
(a)
Where is the double wall's resonance?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
(b)
What does the single panel give at 1000 Hz?
Check
An impedance tube shows a standing-wave ratio of 3.
(a)
What is the magnitude of the sample's reflection coefficient?
(b)
What is its absorption coefficient?
Check
A noise has unweighted band levels of 80 dB at 63 Hz, 70 dB at 500 Hz and 72 dB at 2 kHz; A-weighting is −26.2, −3.2 and +1.2 dB there.
(a)
What is its unweighted level?
(b)
What is its A-weighted level?
Check
A 5 g mass on a 2000 N/m spring with 1 kg/s of resistance is modeled by the impedance analogy.
(a)
At what frequency does the analog circuit resonate?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
(b)
What is its Q?
Check
Two coherent sources give 74 and 74 dB alone at a point, 150° apart in phase.
(a)
What level do they give together?
Check
Sound in a fluid of 1.5 MRayl and 1500 m/s meets one of 2.5 MRayl and 2000 m/s at 20°.
(a)
What is the pressure reflection coefficient?
(b)
Beyond what angle is all the sound reflected?
Check
A small source at 125 Hz gives 2 Pa RMS at 0.1 m in air (ρc = 415 rayl, c = 343 m/s).
(a)
What RMS particle velocity is there?
Write units the way you normally would: 1.5 mm/s, 1500 µm/s and 0.0015 m/s are the same answer.
(b)
What intensity does it carry outward?
Check
A string 1 m long under 100 N has a linear density of 0.5 g/m.
(a)
What is its fundamental?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
(b)
What is its characteristic impedance?
Check
A bar of Young's modulus 70 GPa and density 2700 kg/m³ is 1 m long, clamped at one end and free at the other.
(a)
What is its longitudinal wave speed?
Write units the way you normally would: 1.5 m/s, 1500 mm/s and 0.0015 km/s are the same answer.
(b)
What is its mode 2?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S16