S1633 of 56
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

S16 · Lesson 33 · Room acoustics and reverberation

The diffuse sound field in a room, Sabine's and Eyring's reverberation times, total absorption from surfaces and treatments, the steady-state level as direct plus reverberant sound, the room constant and the critical distance

In 1895 Wallace Sabine was asked to fix a lecture hall at Harvard where speech was unintelligible. Using a pipe organ, a stopwatch and seat cushions borrowed from a nearby theater, he found that the time a sound takes to die away depends only on the room's volume and its total absorption. His formula still sets the first numbers in every concert hall, classroom and recording studio design. A room's reverberation time decides whether speech is clear or muddy and music full or dry, and the balance between direct and reverberant sound decides how far from a talker you can still understand them.

  • Reverberation time of a room against its average absorption coefficient, from Sabine's formula T60=0.161V/Sα¯ and Eyring's T60=0.161V/[−Sln⁡(1−α¯)], for a box of chosen dimensions.
  • For live rooms (small α¯) the two agree; for dead rooms Sabine overestimates: with α¯ = 1 it still predicts some reverberation, where Eyring correctly gives none.
  • Speech rooms aim for 0.5 to 1 s; concert halls for about 2 s.

Predict

A 10 × 8 × 3 m classroom has an average absorption coefficient of 0.15. What's its Sabine reverberation time?

Name it

Reverberation time

After a source stops, sound in a room decays as its energy is absorbed at the surfaces. The reverberation time T60 is the time for the level to fall 60 dB. Sabine found

T60=0.161VA,A=∑iSiαi

with V in m³ and the absorption A in m² (metric sabins); 0.161 s/m is 24 ln 10/c. Eyring's form, T60=0.161V/[−Sln⁡(1−α¯)], is better for absorbent rooms. Large rooms add air absorption, 4mV in the denominator, at high frequencies.

Absorption

Each surface's absorption coefficient α depends on frequency: about 0.02 for painted concrete, 0.1 to 0.3 for typical furnishings, 0.7 to 1 for thick porous absorbers at mid and high frequencies. Adding absorption lowers both T60 and the reverberant level, by 10log⁡(A2/A1) dB.

Direct and reverberant sound

A source of power level LW and directivity factor Q produces, at distance r,

Lp=LW+10log10⁡(Q4πr2+4R),R=Sα¯1−α¯

where R is the room constant. Close to the source the direct term dominates; far away the reverberant field is uniform. They're equal at the critical distance

rc=QR16π

Beyond it, intelligibility depends on the room, not on the talker.

Worked example

Finish the classroom: its room constant, its critical distance for a talker with Q = 2, and the level 5 m from a source of LW = 80 dB.

Show the solution
  1. Room constant. R=268×0.15/0.85=47.3m2
  2. Critical distance. rc=2×47.3/16π=1.37m Most students are in the reverberant field.
  3. Direct and reverberant terms. At 5 m: 24π×25=0.00637447.3=0.0846
  4. Level at 5 m. Lp=80+10log⁡(0.00637+0.0846)=69.6dB almost all reverberant.

Answer a room constant of 47.3 m², a critical distance of 1.37 m, and 69.6 dB at 5 m.

Worked example

30 m² of the classroom's surface (α = 0.1) is covered with panels of α = 0.9. What happens?

Show the solution
  1. Added absorption. ΔA=30×0.8=24m2 bringing A to 64.2 m².
  2. New reverberation time. T60=0.161×240/64.2=0.60s
  3. Level change. The reverberant level drops by 10log⁡(64.2/40.2)=2.0dB
  4. What it buys. It's a large improvement in clarity for a modest level change.

Answer T60 falls to 0.60 s and the reverberant level drops by 2.0 dB.

Worked example

A 100 m³ studio has 130 m² of surface with an average absorption coefficient of 0.5. Compare Sabine's and Eyring's reverberation times.

Show the solution
  1. Sabine. T=0.161×100130×0.5=0.25s
  2. Eyring. It accounts for each reflection removing a fraction ᾱ of the remaining energy: T=0.161V−Sln⁡(1−α¯)=16.1/90.1=0.18s 28% shorter.
  3. When they differ. For lively rooms with ᾱ below about 0.2 the two agree; in heavily treated rooms Sabine overestimates, and at ᾱ = 1 it wrongly predicts a finite reverberation time where Eyring gives zero.

Answer Sabine gives 0.25 s and Eyring 0.18 s, 28% shorter.

Check

A room of 1000 m³ has 20 m² of total absorption. What's its Sabine reverberation time?

Write units the way you normally would: 1.5 s and 1500 ms are the same answer.

Check

A room of 200 m³ has 250 m² of surface with an average absorption coefficient of 0.6. What's its Eyring reverberation time?

Write units the way you normally would: 1.5 s and 1500 ms are the same answer.

Check

A room has 50 m² of surface with α = 0.03, 60 m² with α = 0.9 and 30 m² with α = 0.2. What's its total absorption?

Check

A room with 30 m² of absorption gains 10 m² more. By how much does its reverberant level fall?

Check

A room has 600 m² of surface with average α = 0.1. What's the critical distance for a source with Q = 4?

Write units the way you normally would: 1.5 m, 1500 mm and 0.0015 km are the same answer.

Check

A source of power level 70 dB and Q = 2 is in a room with R = 200 m². What's the level 2 m away?

Check

A room of 500 m³ has 120 m² of surface with average absorption 0.7.

(a)

What reverberation time does Sabine give?

Write units the way you normally would: 1.5 s and 1500 ms are the same answer.

(b)

And Eyring?

Check

A source of power level LW and directivity Q is in a room with room constant R.

Step 1

What level does it produce at distance r?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why does a room's reverberation time depend only on its volume and total absorption, not on its shape or the source's position?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.