title: Room acoustics and reverberation
heading: The diffuse sound field in a room, Sabine's and Eyring's reverberation times, total absorption from surfaces and treatments, the steady-state level as direct plus reverberant sound, the room constant and the critical distance
eyebrow: S16 · Lesson 33 · Room acoustics and reverberation
xp: 50
---

::: hook
In 1895 Wallace Sabine was asked to fix a lecture hall at Harvard where speech was unintelligible. Using a pipe organ, a stopwatch and seat cushions borrowed from a nearby theater, he found that the time a sound takes to die away depends only on the room's volume and its total absorption. His formula still sets the first numbers in every concert hall, classroom and recording studio design. A room's reverberation time decides whether speech is clear or muddy and music full or dry, and the balance between direct and reverberant sound decides how far from a talker you can still understand them.
:::

::: play
- Reverberation time of a room against its average absorption coefficient, from Sabine's formula $T_{60} = 0.161V/S\bar{\alpha}$ and Eyring's $T_{60} = 0.161V/[-S\ln(1 - \bar{\alpha})]$, for a box of chosen dimensions.
- For live rooms (small $\bar{\alpha}$) the two agree; for dead rooms Sabine overestimates: with $\bar{\alpha}$ = 1 it still predicts some reverberation, where Eyring correctly gives none.
- Speech rooms aim for 0.5 to 1 s; concert halls for about 2 s.
:::

```sim plot
view: graph
x: a = 0.02..0.9
y: T = 0..6
slider: x = 4..40 step 1 = 10
slider: y = 4..30 step 1 = 8
slider: z = 2.5..15 step 0.5 = 3
plot: 0.161*x*y*z/(2*(x*y + y*z + x*z)*a) | samples: 300 | label: Sabine, s
plot: 0.161*x*y*z/(-2*(x*y + y*z + x*z)*ln(1 - a)) | samples: 300 | color: ch3 | label: Eyring, s
readout: volume, m³ = x*y*z | digits: 4
readout: surface area, m² = 2*(x*y + y*z + x*z) | digits: 4
```

::: predict
## A 10 × 8 × 3 m classroom has an average absorption coefficient of 0.15. What's its Sabine reverberation time?

- [ ] About 0.3 s
- [x] About 0.96 s
- [ ] About 2.4 s
- [ ] About 6 s

::: reveal
V = 240 m³ and S = 268 m², so the absorption is A = 268 × 0.15 = 40.2 m² (metric sabins), and $T_{60}$ = 0.161 × 240/40.2 = 0.96 s: a little long for a classroom, where 0.6 s or less helps speech. Eyring's formula gives 0.89 s.
:::
:::

::: nameit
## Reverberation time

After a source stops, sound in a room decays as its energy is absorbed at the surfaces. The **reverberation time** $T_{60}$ is the time for the level to fall 60 dB. Sabine found

$$T_{60} = \frac{0.161\,V}{A}, \qquad A = \sum_iS_i\alpha_i$$

with V in m³ and the **absorption** A in m² (metric sabins); 0.161 s/m is 24 ln 10/c. Eyring's form, $T_{60} = 0.161V/[-S\ln(1 - \bar{\alpha})]$, is better for absorbent rooms. Large rooms add air absorption, 4mV in the denominator, at high frequencies.

## Absorption

Each surface's absorption coefficient α depends on frequency: about 0.02 for painted concrete, 0.1 to 0.3 for typical furnishings, 0.7 to 1 for thick porous absorbers at mid and high frequencies. Adding absorption lowers both $T_{60}$ and the reverberant level, by $10\log(A_2/A_1)$ dB.

## Direct and reverberant sound

A source of power level $L_W$ and directivity factor Q produces, at distance r,

$$L_p = L_W + 10\log_{10}\left(\frac{Q}{4\pi r^2} + \frac{4}{R}\right), \qquad R = \frac{S\bar{\alpha}}{1 - \bar{\alpha}}$$

where R is the **room constant**. Close to the source the direct term dominates; far away the reverberant field is uniform. They're equal at the **critical distance**

$$r_c = \sqrt{\frac{QR}{16\pi}}$$

Beyond it, intelligibility depends on the room, not on the talker.
:::

::: example
## Finish the classroom: its room constant, its critical distance for a talker with Q = 2, and the level 5 m from a source of $L_W$ = 80 dB.

::: solution
1. **Room constant.**
   $$\begin{aligned} R &= 268 \times 0.15/0.85 \\ &= 47.3\ \text{m}^2 \end{aligned}$$
2. **Critical distance.**
   $$\begin{aligned} r_c &= \sqrt{2 \times 47.3/16\pi} \\ &= 1.37\ \text{m} \end{aligned}$$
   Most students are in the reverberant field.
3. **Direct and reverberant terms.** At 5 m:
   $$\begin{aligned} \frac{2}{4\pi \times 25} &= 0.00637 \\ \frac{4}{47.3} &= 0.0846 \end{aligned}$$
4. **Level at 5 m.**
   $$\begin{aligned} L_p &= 80 + 10\log(0.00637 + 0.0846) \\ &= 69.6\ \text{dB} \end{aligned}$$
   almost all reverberant.

**Answer:** a room constant of 47.3 m², a critical distance of 1.37 m, and 69.6 dB at 5 m.
:::
:::

::: example
## 30 m² of the classroom's surface (α = 0.1) is covered with panels of α = 0.9. What happens?

::: solution
1. **Added absorption.**
   $$\begin{aligned} \Delta A &= 30 \times 0.8 \\ &= 24\ \text{m}^2 \end{aligned}$$
   bringing A to 64.2 m².
2. **New reverberation time.**
   $$\begin{aligned} T_{60} &= 0.161 \times 240/64.2 \\ &= 0.60\ \text{s} \end{aligned}$$
3. **Level change.** The reverberant level drops by
   $$10\log(64.2/40.2) = 2.0\ \text{dB}$$
4. **What it buys.** It's a large improvement in clarity for a modest level change.

**Answer:** $T_{60}$ falls to 0.60 s and the reverberant level drops by 2.0 dB.
:::
:::

::: example
## A 100 m³ studio has 130 m² of surface with an average absorption coefficient of 0.5. Compare Sabine's and Eyring's reverberation times.

::: solution
1. **Sabine.**
   $$\begin{aligned} T &= \frac{0.161 \times 100}{130 \times 0.5} \\ &= 0.25\ \text{s} \end{aligned}$$
2. **Eyring.** It accounts for each reflection removing a fraction ᾱ of the remaining energy:
   $$\begin{aligned} T &= \frac{0.161V}{-S\ln(1 - \bar{\alpha})} \\ &= 16.1/90.1 \\ &= 0.18\ \text{s} \end{aligned}$$
   28% shorter.
3. **When they differ.** For lively rooms with ᾱ below about 0.2 the two agree; in heavily treated rooms Sabine overestimates, and at ᾱ = 1 it wrongly predicts a finite reverberation time where Eyring gives zero.

**Answer:** Sabine gives 0.25 s and Eyring 0.18 s, 28% shorter.
:::
:::

::: check
given: V = 100 | 1000 | 15000; A = 20 | 150 | 1200
answer: 0.161*V/A
unit: s
tolerance: 0.5%

## A room of {V} m³ has {A} m² of total absorption. What's its Sabine reverberation time?

::: right
Right. $0.161V/A$ = {answer} s.
:::

::: misses
- [any] Not yet. Sabine's formula.
:::
:::

::: check
given: V = 200 | 2000; S = 250 | 1200; a = 0.3 | 0.6
answer: 0.161*V/(-S*ln(1 - a))
unit: s
tolerance: 0.5%

## A room of {V} m³ has {S} m² of surface with an average absorption coefficient of {a}. What's its Eyring reverberation time?

::: right
Right. $0.161V/[-S\ln(1 - \bar{\alpha})]$ = {answer} s.
:::

::: misses
- [0.161*V/(S*a)] That's Sabine's; Eyring uses $-\ln(1 - \bar{\alpha})$.
- [any] Not yet. Eyring's formula.
:::
:::

::: check
given: a = 50 | 120; p = 0.03 | 0.1; b = 20 | 60; q = 0.6 | 0.9; c = 30 | 80; r = 0.2 | 0.4
answer: a*p + b*q + c*r
unit: m²
tolerance: 0.5%

## A room has {a} m² of surface with α = {p}, {b} m² with α = {q} and {c} m² with α = {r}. What's its total absorption?

::: right
Right. $\sum S_i\alpha_i$ = {answer} m².
:::

::: misses
- [any] Not yet. Area times coefficient, summed.
:::
:::

::: check
given: A = 30 | 80; B = 10 | 40 | 100
answer: 10*log((A + B)/A)
unit: dB
tolerance: 0.5%

## A room with {A} m² of absorption gains {B} m² more. By how much does its reverberant level fall?

::: right
Right. $10\log(A_2/A_1)$ = {answer} dB.
:::

::: misses
- [20*log((A + B)/A)] Reverberant energy scales as 1/A: use 10 log.
- [any] Not yet. Compare the absorptions.
:::
:::

::: check
given: S = 200 | 600 | 2000; a = 0.1 | 0.25 | 0.5; Q = 1 | 2 | 4
answer: sqrt(Q*S*a/(1 - a)/(16*pi))
unit: m
tolerance: 0.5%

## A room has {S} m² of surface with average α = {a}. What's the critical distance for a source with Q = {Q}?

::: right
Right. $\sqrt{QR/16\pi}$ with R = $S\bar{\alpha}/(1 - \bar{\alpha})$: {answer} m.
:::

::: misses
- [sqrt(Q*S*a/(16*pi))] Use the room constant $R = S\bar{\alpha}/(1 - \bar{\alpha})$.
- [any] Not yet. Room constant first.
:::
:::

::: check
given: W = 70 | 90; r = 2 | 8; R = 30 | 200; Q = 1 | 2
answer: W + 10*log(Q/(4*pi*r^2) + 4/R)
unit: dB
tolerance: 0.1%

## A source of power level {W} dB and Q = {Q} is in a room with R = {R} m². What's the level {r} m away?

::: right
Right. $L_W + 10\log(Q/4\pi r^2 + 4/R)$ = {answer} dB.
:::

::: misses
- [W + 10*log(Q/(4*pi*r^2))] Add the reverberant field, 4/R.
- [any] Not yet. Direct plus reverberant.
:::
:::

::: check
kind: parts
given: V = 80 | 500 | 3000; S = 120 | 450 | 1300; a = 0.1 | 0.4 | 0.7

## A room of {V} m³ has {S} m² of surface with average absorption {a}.

::: part
answer: 0.161*V/(S*a)
unit: s
tolerance: 0.5%

### What reverberation time does Sabine give?

::: misses
- [any] $0.161V/S\bar\alpha$.
:::
:::

::: part
answer: 0.161*V/(-S*ln(1 - a))
unit: s
tolerance: 0.5%

### And Eyring?

::: misses
- [0.161*V/(-S*log(1 - a))] Eyring's formula uses the natural logarithm.
- [any] $0.161V/[-S\ln(1 - \bar\alpha)]$.
:::
:::
:::

::: check
kind: derivation
vars: W = 50..130, Q = 1..8, r = 0.5..50, R = 5..5000

## A source of power level $L_W$ and directivity Q is in a room with room constant R.

::: step
answer: W + 10*log(Q/(4*pi*r^2) + 4/R)

### What level does it produce at distance r?
:::

::: step
answer: sqrt(Q*R/(16*pi))

### At what distance do direct and reverberant sound match?
:::

::: right
Right. Beyond the critical distance, moving away hardly lowers the level.
:::
:::

::: explain
## Why does a room's reverberation time depend only on its volume and total absorption, not on its shape or the source's position?

::: model
After many reflections, sound in a room is spread roughly evenly and travels in all directions: a diffuse field. Its energy is proportional to the volume, while the rate at which energy is removed depends on how often sound strikes the surfaces and how much each strike absorbs, which for a diffuse field is proportional to the total absorption $\sum S\alpha$. The ratio of stored energy to loss rate gives an exponential decay whose time constant is proportional to V/A, independent of where the source was or what shape the room is. The assumption fails in rooms with very uneven absorption, strongly coupled spaces, or at low frequencies where individual modes dominate.
:::
:::

::: practice

::: check
given: V = 30 | 30000; A = 5 | 3000
answer: 0.161*V/A
unit: s
tolerance: 0.5%

## Sabine: {V} m³, {A} m²?

::: misses
- [any] $0.161V/A$.
:::
:::

::: check
given: S = 50 | 5000; a = 0.05 | 0.8; Q = 1 | 8
answer: sqrt(Q*S*a/(1 - a)/(16*pi))
unit: m
tolerance: 0.5%

## Critical distance: S = {S} m², α = {a}, Q = {Q}?

::: misses
- [any] $\sqrt{QR/16\pi}$.
:::
:::

::: check
given: W = 50 | 120; r = 0.5 | 30; R = 10 | 2000; Q = 1 | 4
answer: W + 10*log(Q/(4*pi*r^2) + 4/R)
unit: dB
tolerance: 0.1%

## SPL: $L_W$ = {W}, Q = {Q}, r = {r} m, R = {R} m²?

::: misses
- [any] $L_W + 10\log(Q/4\pi r^2 + 4/R)$.
:::
:::
:::