S1636 of 56
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

S16 · Lesson 36 · Room and noise lab

Reverberation times from a noisy impulse response by Schroeder integration, how the noise floor biases T30 but not T20, equivalent and exceeded levels from a record of levels, noise dose under two criteria, and Sabine, Eyring and critical distance for a room with several surfaces

An acoustic consultant's day turns measurements into a handful of numbers: a room's reverberation time, a site's equivalent and exceeded levels, a worker's daily dose. Lessons 29 to 35 gave the definitions. In this lab you'll compute them from raw data, a synthetic impulse response with realistic fluctuations and a noise floor, a list of logged levels and a shift's exposure profile, and see where the definitions hide judgment calls.

  • For a noise whose level, in decibels, is Gaussian with standard deviation σ, the solid curve is how far the equivalent level sits above the median, Leq−L50=0.115σ2, and the dashed one how far L10 sits above it, 1.28σ.
  • Steady noise (small σ) has all three nearly equal. Fluctuating noise, like traffic with occasional trucks, has an equivalent level pulled well above the median by the loud moments.
  • Task 2 computes these statistics from a logged record without assuming any distribution.

Predict

An impulse response with a 1.2 s reverberation time ends in noise 50 dB below its peak. What does a T30 fit report?

Name it

What the lab computes

  • Schroeder integration: the decay curve 10log⁡[∑j≥ihj2/∑jhj2], and reverberation time from the least-squares slope s (dB/s) of the points between −5 and −35 dB (T30) or −5 and −25 dB (T20): T = −60/s.
  • Level statistics: from N logged levels, Leq=10log⁡[1N∑10Li/10], and the exceeded levels L10, L50 and L90 read from the sorted list.
  • Dose: each period t at level L counts t/Tallowed(L), with Tallowed=8/2(L−85)/3 hours for NIOSH and 8/2(L−90)/5 for OSHA.
  • Rooms: Sabine 0.161V/(A+4mV), Eyring 0.161V/[−Sln⁡(1−α¯)+4mV], the room constant R=Sα¯/(1−α¯) and the critical distance QR/16π.

Check

Write decay_curve(h2) returning the Schroeder curve in dB, and rt(curve, dt, top=-5, bottom=-35) returning the reverberation time from the fit between those levels.

Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.

Check

Write level_stats(levels) returning (Leq, L10, L50, L90), with Lx the sorted list's entry exceeded x% of the time (nearest rank).

Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.

Check

Write dose(profile, criterion) for a list of (level in dB(A), hours) and criterion "NIOSH" or "OSHA", returning percent.

Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.

Check

Write room(V, surfaces, m=0.0, Q=2) for a list of (area, α) returning (Sabine T, Eyring T, critical distance).

Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.

Explain why

Why does background noise make a measured reverberation time too long rather than too short?