S16 · Lesson 10 · Sound transmission through walls
Transmission loss of a limp wall and the mass law, normal and field incidence, the coincidence dip where bending waves match sound in air, composite walls and the damage done by a small opening
Most of a wall's ability to stop sound comes from its mass. A sound wave pushes on the wall, the wall moves a little and becomes a new, much quieter source on the other side, and a heavier wall moves less. That simple picture, the mass law, says each doubling of mass or of frequency adds 6 dB of isolation. It also explains two classic disappointments: a wall that leaks badly at one frequency band, where its bending waves line up with the sound in air, and a heavy wall made useless by a gap under the door.
- Transmission loss of a limp panel with surface density m (kg/m²) at normal incidence, , and the field-incidence estimate for sound arriving from all directions, about 5 dB lower: .
- Doubling the frequency or the mass adds 6 dB once the panel is mass-controlled.
- Real panels also have a coincidence dip, where the sim's simple law overestimates them.
Predict
A wall's 12 m² has a transmission loss of 45 dB, but 1% of its area is an open gap. Roughly what transmission loss does the whole wall have?
Transmission coefficients add by area: the wall passes 0.99 × 10⁻⁴·⁵ ≈ 3 × 10⁻⁵ and the gap passes 0.01 × 1. The average is about 0.0100, and −10 log 0.0100 = 20.0 dB. The gap carries 300 times the sound the wall does, so sealing it matters more than doubling the wall.
Name it
The mass law
A limp panel of surface density m between two airspaces, hit at normal incidence, transmits
Once , dB in air. Sound arriving from all directions does about 5 dB worse: dB. Either way, doubling m or f adds 6 dB.
Coincidence
A panel carries bending waves whose speed rises with frequency (lesson 4). At the critical frequency, where the bending speed equals the speed of sound in air,
the panel radiates efficiently and the transmission loss dips below the mass law, for 6 mm glass around 2 kHz. Stiff, light panels have low critical frequencies in the middle of the speech band, which is a problem; heavy, limp ones push it higher.
Composite walls
Parts of a wall with areas and transmission coefficients transmit on average
The weakest element dominates: a door, a window or a gap sets the wall's real performance. Double walls with an air gap and absorption in between beat the mass law, except near the mass-air-mass resonance.
Worked example
A 20 kg/m² panel at 500 Hz: what do the exact normal-incidence law and the field-incidence estimate give? What's the critical frequency of 6 mm glass with = 5200 m/s?
Show the solution
- Mass-law ratio.
- Normal incidence.
- Field incidence. In a diffuse field, with mf = 10,000:
- Critical frequency of the glass.
Answer the panel gives 37.6 dB at normal incidence and 33 dB in a diffuse field, and the glass's critical frequency is 2080 Hz.
Worked example
A 12 m² wall of 45 dB contains a 2 m² door of 25 dB. What's the combined transmission loss?
Show the solution
- The wall's share. Its 10 m² passes
- The door's share.
- Average transmission coefficient.
- Transmission loss.
- Where the sound goes. The door, a sixth of the area, carries 95% of the sound.
Answer the combined transmission loss is 32.6 dB.
Worked example
A double wall has two 10 kg/m² panels 50 mm apart, with air between. Where is its mass–air–mass resonance?
Show the solution
- The air as a spring. The air gap acts as a spring between the two masses, resonating at
- Put in the numbers.
- Below and near the resonance. Below it the wall acts as one 20 kg/m² mass, and near it transmission rises sharply.
- Above the resonance. Well above it, the two panels' insulation adds and the wall far outperforms a single panel of the same total mass.
- What designers do. They push below the frequencies that matter with deeper gaps and fill the gap with absorbent to damp the resonance.
Answer the mass–air–mass resonance is at 120 Hz.
Check
A limp panel of 20 kg/m² is hit at normal incidence by sound at 125 Hz. What's its transmission loss?
Check
About what transmission loss does a 50 kg/m² wall have for diffuse sound at 250 Hz?
Check
A wall's surface density goes from 10 to 40 kg/m². By how much does its mass-law transmission loss rise?
Check
A panel 6 mm thick has a plate wave speed = 3000 m/s. What's its critical (coincidence) frequency in air?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
Check
An 8 m² partition rated 40 dB includes a 2.5 m² door rated 30 dB. What's the partition's overall transmission loss?
Check
A wall rated 50 dB has open gaps making up a fraction 0.001 of its area. What's its effective transmission loss?
Check
A double wall with panels of 12 and 8 kg/m² must have its mass–air–mass resonance at 80 Hz (air: ρ₀ = 1.2 kg/m³, c = 343 m/s).
(a)
How deep must the air gap be?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
Check
A limp panel of surface density m (kg/m²) meets sound at frequency f in air (ρc = 415 rayl).
Step 1
What normal-incidence transmission loss does the mass law give?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
About what field-incidence loss?
Explain why
Why does the transmission loss of a single wall rise by 6 dB per doubling of its mass?
Well above any resonance, a wall struck by sound is controlled by its inertia: the pressure difference across it accelerates it, and its velocity is the force divided by its mass and by the angular frequency. The wall's motion then radiates sound on the far side with a pressure proportional to that velocity. Doubling the mass halves the velocity, halving the transmitted pressure and quartering the transmitted intensity, which is 6 dB; doubling the frequency does the same because the same force produces half the velocity at twice the frequency. That's why heavy materials, concrete, brick and layered drywall, are used for isolation, and why light walls are poor at low frequencies.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.