title: Sound transmission through walls
heading: Transmission loss of a limp wall and the mass law, normal and field incidence, the coincidence dip where bending waves match sound in air, composite walls and the damage done by a small opening
eyebrow: S16 · Lesson 10 · Sound transmission through walls
xp: 50
---

::: hook
Most of a wall's ability to stop sound comes from its mass. A sound wave pushes on the wall, the wall moves a little and becomes a new, much quieter source on the other side, and a heavier wall moves less. That simple picture, the mass law, says each doubling of mass or of frequency adds 6 dB of isolation. It also explains two classic disappointments: a wall that leaks badly at one frequency band, where its bending waves line up with the sound in air, and a heavy wall made useless by a gap under the door.
:::

::: play
- Transmission loss of a limp panel with surface density m (kg/m²) at normal incidence, $TL = 10\log[1 + (\pi fm/\rho_0c)^2]$, and the field-incidence estimate for sound arriving from all directions, about 5 dB lower: $20\log(fm) - 47$.
- Doubling the frequency or the mass adds 6 dB once the panel is mass-controlled.
- Real panels also have a coincidence dip, where the sim's simple law overestimates them.
:::

```sim plot
view: graph
x: f = 50..5000 log
y: T = 0..80
slider: m = 2..400 = 20 log
plot: 10*log(1 + (pi*f*m/415)^2) | samples: 300 | label: normal-incidence mass law, dB
plot: 20*log(f*m) - 47 | samples: 300 | dashed | color: ch3 | label: field incidence, dB
readout: normal incidence at 500 Hz, dB = 10*log(1 + (pi*500*m/415)^2) | digits: 3
```

::: predict
## A wall's 12 m² has a transmission loss of 45 dB, but 1% of its area is an open gap. Roughly what transmission loss does the whole wall have?

- [ ] 45 dB
- [ ] About 44.6 dB
- [x] About 20 dB
- [ ] About 1 dB

::: reveal
Transmission coefficients add by area: the wall passes 0.99 × 10⁻⁴·⁵ ≈ 3 × 10⁻⁵ and the gap passes 0.01 × 1. The average is about 0.0100, and −10 log 0.0100 = 20.0 dB. The gap carries 300 times the sound the wall does, so sealing it matters more than doubling the wall.
:::
:::

::: nameit
## The mass law

A limp panel of surface density m between two airspaces, hit at normal incidence, transmits

$$\tau = \frac{1}{1 + (\omega m/2\rho_0c)^2}, \qquad TL = 10\log_{10}\frac{1}{\tau}$$

Once $\omega m \gg 2\rho_0c$, $TL \approx 20\log_{10}(fm) - 42.4$ dB in air. Sound arriving from all directions does about 5 dB worse: $TL \approx 20\log_{10}(fm) - 47$ dB. Either way, doubling m or f adds 6 dB.

## Coincidence

A panel carries bending waves whose speed rises with frequency (lesson 4). At the **critical frequency**, where the bending speed equals the speed of sound in air,

$$f_c = \frac{c^2}{2\pi\kappa c_L} = \frac{c^2\sqrt{12}}{2\pi tc_L}$$

the panel radiates efficiently and the transmission loss dips below the mass law, for 6 mm glass around 2 kHz. Stiff, light panels have low critical frequencies in the middle of the speech band, which is a problem; heavy, limp ones push it higher.

## Composite walls

Parts of a wall with areas $S_i$ and transmission coefficients $\tau_i = 10^{-TL_i/10}$ transmit on average

$$\bar{\tau} = \frac{\sum S_i\tau_i}{\sum S_i}, \qquad TL = -10\log_{10}\bar{\tau}$$

The weakest element dominates: a door, a window or a gap sets the wall's real performance. Double walls with an air gap and absorption in between beat the mass law, except near the mass-air-mass resonance.
:::

::: example
## A 20 kg/m² panel at 500 Hz: what do the exact normal-incidence law and the field-incidence estimate give? What's the critical frequency of 6 mm glass with $c_L$ = 5200 m/s?

::: solution
1. **Mass-law ratio.**
   $$\begin{aligned} \frac{\omega m}{2\rho_0c} &= \frac{\pi \times 500 \times 20}{415} \\ &= 75.7 \end{aligned}$$
2. **Normal incidence.**
   $$\begin{aligned} \text{TL} &= 10\log(1 + 75.7^2) \\ &= 37.6\ \text{dB} \end{aligned}$$
3. **Field incidence.** In a diffuse field, with mf = 10,000:
   $$\begin{aligned} \text{TL} &= 20\log(10{,}000) - 47 \\ &= 33\ \text{dB} \end{aligned}$$
4. **Critical frequency of the glass.**
   $$\begin{aligned} f_c &= \frac{343^2 \times \sqrt{12}}{2\pi \times 0.006 \times 5200} \\ &= 2080\ \text{Hz} \end{aligned}$$

**Answer:** the panel gives 37.6 dB at normal incidence and 33 dB in a diffuse field, and the glass's critical frequency is 2080 Hz.
:::
:::

::: example
## A 12 m² wall of 45 dB contains a 2 m² door of 25 dB. What's the combined transmission loss?

::: solution
1. **The wall's share.** Its 10 m² passes
   $$10 \times 10^{-4.5} = 3.2 \times 10^{-4}$$
2. **The door's share.**
   $$2 \times 10^{-2.5} = 6.3 \times 10^{-3}$$
3. **Average transmission coefficient.**
   $$\begin{aligned} \bar{\tau} &= \frac{6.6 \times 10^{-3}}{12} \\ &= 5.5 \times 10^{-4} \end{aligned}$$
4. **Transmission loss.**
   $$\begin{aligned} \text{TL} &= -10\log\bar{\tau} \\ &= 32.6\ \text{dB} \end{aligned}$$
5. **Where the sound goes.** The door, a sixth of the area, carries 95% of the sound.

**Answer:** the combined transmission loss is 32.6 dB.
:::
:::

::: example
## A double wall has two 10 kg/m² panels 50 mm apart, with air between. Where is its mass–air–mass resonance?

::: solution
1. **The air as a spring.** The air gap acts as a spring between the two masses, resonating at
   $$f_0 = \frac{1}{2\pi}\sqrt{\frac{\rho_0c^2(m_1 + m_2)}{d\,m_1m_2}}$$
2. **Put in the numbers.**
   $$\begin{aligned} f_0 &= \frac{1}{2\pi}\sqrt{\frac{1.2 \times 343^2 \times 20}{0.05 \times 100}} \\ &= 120\ \text{Hz} \end{aligned}$$
3. **Below and near the resonance.** Below it the wall acts as one 20 kg/m² mass, and near it transmission rises sharply.
4. **Above the resonance.** Well above it, the two panels' insulation adds and the wall far outperforms a single panel of the same total mass.
5. **What designers do.** They push $f_0$ below the frequencies that matter with deeper gaps and fill the gap with absorbent to damp the resonance.

**Answer:** the mass–air–mass resonance is at 120 Hz.
:::
:::

::: check
given: m = 5 | 20 | 100; f = 125 | 500 | 2000
answer: 10*log(1 + (pi*f*m/415)^2)
unit: dB
tolerance: 0.5%

## A limp panel of {m} kg/m² is hit at normal incidence by sound at {f} Hz. What's its transmission loss?

::: right
Right. $10\log[1 + (\pi fm/\rho_0c)^2]$ = {answer} dB.
:::

::: misses
- [10*log(1 + (2*pi*f*m/415)^2)] The ratio is $\omega m/2\rho_0c = \pi fm/\rho_0c$.
- [any] Not yet. The mass law at normal incidence.
:::
:::

::: check
given: m = 10 | 50 | 200; f = 250 | 1000
answer: 20*log(f*m) - 47
unit: dB
tolerance: 0.5%

## About what transmission loss does a {m} kg/m² wall have for diffuse sound at {f} Hz?

::: right
Right. $20\log(fm) - 47$ = {answer} dB.
:::

::: misses
- [20*log(f*m) - 42.4] That's the normal-incidence version; a diffuse field does about 5 dB worse.
- [any] Not yet. The field-incidence mass law.
:::
:::

::: check
given: a = 10 | 25; b = 40 | 100 | 200
answer: 20*log(b/a)
unit: dB
tolerance: 0.5%

## A wall's surface density goes from {a} to {b} kg/m². By how much does its mass-law transmission loss rise?

::: right
Right. $20\log(m_2/m_1)$ = {answer} dB.
:::

::: misses
- [10*log(b/a)] The mass law goes as 20 log m.
- [any] Not yet. 6 dB per doubling.
:::
:::

::: check
given: t = 3 | 6 | 12; c = 3000 | 5200 | 5500
answer: 343^2*sqrt(12)/(2*pi*t*1e-3*c)
unit: Hz
tolerance: 0.5%

## A panel {t} mm thick has a plate wave speed $c_L$ = {c} m/s. What's its critical (coincidence) frequency in air?

::: right
Right. $c^2\sqrt{12}/(2\pi tc_L)$ = {answer} Hz.
:::

::: misses
- [343^2/(2*pi*t*1e-3*c)] Use the radius of gyration $t/\sqrt{12}$.
- [any] Not yet. Where the bending speed reaches 343 m/s.
:::
:::

::: check
given: W = 40 | 50; S = 8 | 15; D = 20 | 30; d = 1.5 | 2.5
answer: -10*log(((S - d)*10^(-W/10) + d*10^(-D/10))/S)
unit: dB
tolerance: 0.5%

## A {S} m² partition rated {W} dB includes a {d} m² door rated {D} dB. What's the partition's overall transmission loss?

::: right
Right. $-10\log\bar{\tau}$ = {answer} dB.
:::

::: misses
- [((S - d)*W + d*D)/S] Average the transmission coefficients, not the decibels.
- [any] Not yet. Area-weighted τ.
:::
:::

::: check
given: W = 35 | 50 | 60; p = 0.001 | 0.01
answer: -10*log((1 - p)*10^(-W/10) + p)
unit: dB
tolerance: 0.5%

## A wall rated {W} dB has open gaps making up a fraction {p} of its area. What's its effective transmission loss?

::: right
Right. {answer} dB.
:::

::: misses
- [W] An opening transmits everything that reaches it.
- [any] Not yet. Gaps have τ = 1.
:::
:::

::: check
kind: parts
given: a = 8 | 12 | 25; b = 8 | 20; f = 50 | 80

## A double wall with panels of {a} and {b} kg/m² must have its mass–air–mass resonance at {f} Hz (air: ρ₀ = 1.2 kg/m³, c = 343 m/s).

::: part
answer: 1.2*343^2*(a + b)/((2*pi*f)^2*a*b)*1000
unit: mm
tolerance: 0.5%

### How deep must the air gap be?

::: misses
- [1.2*343^2*(a + b)/(f^2*a*b)*1000] Use the angular frequency, 2πf.
- [any] Solve $f_0 = \frac1{2\pi}\sqrt{\rho_0c^2(m_1 + m_2)/(dm_1m_2)}$ for d.
:::
:::
:::

::: check
kind: derivation
vars: m = 1..500, f = 20..10000

## A limp panel of surface density m (kg/m²) meets sound at frequency f in air (ρc = 415 rayl).

::: step
answer: 10*log(1 + (2*pi*f*m/(2*415))^2)

### What normal-incidence transmission loss does the mass law give?
:::

::: step
answer: 10*log(1 + (2*pi*f*m/(2*415))^2) - 5

### About what field-incidence loss?
:::

::: right
Right. Doubling either mass or frequency adds about 6 dB.
:::
:::

::: explain
## Why does the transmission loss of a single wall rise by 6 dB per doubling of its mass?

::: model
Well above any resonance, a wall struck by sound is controlled by its inertia: the pressure difference across it accelerates it, and its velocity is the force divided by its mass and by the angular frequency. The wall's motion then radiates sound on the far side with a pressure proportional to that velocity. Doubling the mass halves the velocity, halving the transmitted pressure and quartering the transmitted intensity, which is 6 dB; doubling the frequency does the same because the same force produces half the velocity at twice the frequency. That's why heavy materials, concrete, brick and layered drywall, are used for isolation, and why light walls are poor at low frequencies.
:::
:::

::: practice

::: check
given: m = 1 | 500; f = 50 | 5000
answer: 10*log(1 + (pi*f*m/415)^2)
unit: dB
tolerance: 0.5%

## Normal-incidence TL: {m} kg/m², {f} Hz?

::: misses
- [any] $10\log[1 + (\pi fm/\rho c)^2]$.
:::
:::

::: check
given: t = 1 | 25; c = 2000 | 5500
answer: 343^2*sqrt(12)/(2*pi*t*1e-3*c)
unit: Hz
tolerance: 0.5%

## Critical frequency: {t} mm, $c_L$ = {c}?

::: misses
- [any] $c^2\sqrt{12}/(2\pi tc_L)$.
:::
:::

::: check
given: W = 30 | 65; p = 0.0001 | 0.05
answer: -10*log((1 - p)*10^(-W/10) + p)
unit: dB
tolerance: 0.5%

## Wall {W} dB with open fraction {p}?

::: misses
- [any] Area-weighted τ with τ = 1 for gaps.
:::
:::
:::