title: Vibration isolation
heading: Keeping vibration out of a structure or a sensitive instrument, transmissibility and why isolation only starts above √2 times the natural frequency, mounts chosen by their static deflection, the damping trade-off, two-stage mounts, and tuned vibration absorbers
eyebrow: S16 · Lesson 2 · Vibration isolation
xp: 50
---

::: hook
A pump bolted to a floor shakes the building; the same pump on springs barely disturbs it. An electron microscope on a bare floor blurs with the footsteps next door; on a soft mount it doesn't. Both are the oscillator of lesson 1, used backward: instead of making something ring, the goal is to make a resonance sit so far below the disturbing frequency that hardly any force gets through. The physics fits on one curve, and the design comes down to choosing a spring.
:::

::: play
- The curve is the transmissibility of a spring-mounted mass, the fraction of a vibrating force (or base motion) that gets through the mount, against the ratio r of the disturbing frequency to the mount's natural frequency, for the damping ratio on the slider.
- Below r = √2 the mount makes things worse, with a peak at resonance limited only by damping. Above √2 it isolates, increasingly with frequency.
- More damping tames the resonance but lets more through at high frequency: the price of a quieter start-up is poorer isolation in running.
:::

```sim plot
view: graph
x: r = 0.1..20 log
y: T = 0.001..100 log
slider: z = 0.01..0.7 = 0.05
plot: sqrt(1 + (2*z*r)^2)/sqrt((1 - r^2)^2 + (2*z*r)^2) | label: transmissibility
plot: 1 + 0*r | dashed | label: no isolation
```

::: predict
## A 50 Hz motor sits on springs that compress 5 mm under its weight. With 5% damping, what fraction of its vibrating force reaches the floor?

- [ ] About 100%
- [ ] About 25%
- [x] About 2.5%
- [ ] About 0.01%

::: reveal
A mount that deflects δ under static load has $f_0 = \frac1{2\pi}\sqrt{g/\delta}$ = 7.05 Hz, so r = 7.09 and the transmissibility is $\sqrt{1 + (2\zeta r)^2}/\sqrt{(1 - r^2)^2 + (2\zeta r)^2}$ = 0.025: a 32 dB reduction. The static deflection alone sets the natural frequency, whatever the mass.
:::
:::

::: nameit
## Transmissibility

A mass m on a mount of stiffness k and damping c has natural frequency $f_0 = \frac1{2\pi}\sqrt{k/m}$. The ratio of force transmitted to the foundation to force applied, or equally of the mass's motion to a vibrating base's, is
$$T = \frac{\sqrt{1 + (2\zeta r)^2}}{\sqrt{(1 - r^2)^2 + (2\zeta r)^2}}, \qquad r = \frac f{f_0}$$
At r = √2, T = 1 whatever the damping; above it T falls, at high frequency as $2\zeta/r$ with damping and as $1/r^2$, 40 dB per decade, without.

## Choosing a mount

Since $k = mg/\delta$, the natural frequency depends only on the static deflection: $f_0 = \frac1{2\pi}\sqrt{g/\delta} \approx 15.8/\sqrt{\delta_\text{mm}}$ Hz. Good isolation needs r of 3 or more, so a machine running at 25 Hz needs a mount deflecting at least about 3.5 mm, and floor-borne disturbances at a few hertz need soft air springs. Damping is a compromise: it limits the peak a machine passes through while starting, but spoils isolation above resonance; elastomer mounts with ζ of 0.05 to 0.1 are a common balance.

## Two stages

Putting an intermediate mass between two sets of springs makes a two-stage mount whose transmissibility falls as $1/r^4$, 80 dB per decade, above its second resonance: the approach used for sensitive instruments and for the suspensions of gravitational-wave detectors.

## Tuned absorbers

When a structure resonates near a forcing frequency, a small mass on a spring tuned to that frequency can cancel its motion. With mass ratio μ (absorber to structure), Den Hartog's optimum tunes the absorber to $f_a = f_0/(1 + \mu)$ with damping $\zeta_\text{opt} = \sqrt{3\mu/[8(1 + \mu)^3]}$, which flattens the response over a band rather than leaving two sharp peaks. Tall buildings and long footbridges carry such dampers.
:::

::: example
## Repeat the predict question with 30% damping. What has the extra damping bought and cost?

::: solution
1. **Isolation at 30% damping.** At r = 7.09 and ζ = 0.3, 2ζr = 4.26, so
   $$\begin{aligned} T &= \frac{\sqrt{1 + 4.26^2}}{\sqrt{(1 - 50.3)^2 + 4.26^2}} \\ &= 0.088 \end{aligned}$$
   a 21 dB reduction instead of 32.
2. **Peak at start-up.** A starting motor passes through the resonance at 7 Hz, which now peaks at
   $$\begin{aligned} T &= \frac{\sqrt{1 + 0.36}}{0.6} \\ &\approx 1.9 \end{aligned}$$
   instead of about 10.
3. **The usual compromise.** Many installations keep light damping and add snubbers or briefly lock the mount during start-up instead.

**Answer:** the extra damping lowers the start-up resonance peak from about 10 to 1.9, and it costs isolation at 50 Hz: a 21 dB reduction instead of 32.
:::
:::

::: example
## An optical table must reduce 10 Hz floor vibration. What does a mount with a 2 Hz natural frequency and 5% damping achieve, and what static deflection would steel springs need for that?

::: solution
1. **Frequency ratio.**
   $$\begin{aligned} r &= 10/2 \\ &= 5 \end{aligned}$$
2. **Transmissibility.** With ζ = 0.05, 2ζr = 0.5, so
   $$\begin{aligned} T &= \frac{\sqrt{1 + 0.25}}{\sqrt{24^2 + 0.25}} \\ &= 0.047 \end{aligned}$$
   a 27 dB reduction.
3. **Static deflection.** A 2 Hz spring mount would sag under the table's weight by
   $$\begin{aligned} \delta &= \frac{g}{(2\pi f_0)^2} \\ &= 62\ \text{mm} \end{aligned}$$
4. **Why air springs.** That's impractical for steel springs, which is why such tables float on pneumatic legs whose stiffness comes from compressed air.

**Answer:** the mount passes 0.047 of the vibration, a 27 dB reduction, but steel springs would need 62 mm of static deflection, so such tables use pneumatic legs.
:::
:::

::: example
## A floor slab resonates near the 2 Hz pace of walking. A tuned mass damper of 5% of the slab's modal mass is added. How should it be tuned and damped?

::: solution
1. **Tuning.** Den Hartog's rule, with μ = 0.05:
   $$\begin{aligned} f_a &= \frac{f_0}{1 + \mu} \\ &= \frac{2}{1.05} \\ &= 1.90\ \text{Hz} \end{aligned}$$
2. **Damping.**
   $$\begin{aligned} \zeta &= \sqrt{\frac{3 \times 0.05}{8 \times 1.05^3}} \\ &= 0.127 \end{aligned}$$
3. **What it does.** Tuned slightly below the structure and fairly heavily damped, the absorber spreads the single resonant peak into two low, broad ones, so footfalls near 2 Hz no longer build up large motions.

**Answer:** tune the damper to 1.90 Hz and give it a damping ratio of 0.127.
:::
:::

::: check
kind: parts
given: d = 1 | 5 | 25; f = 15 | 50 | 120; z = 0.02 | 0.1

## A machine running at {f} Hz sits on mounts that deflect {d} mm under its weight, with damping ratio {z}.

::: part
answer: 1/(2*pi)*sqrt(9.81/(d*1e-3))
unit: Hz
tolerance: 0.5%

### What is the mount's natural frequency?

::: misses
- [sqrt(9.81/(d*1e-3))] That's in radians per second.
- [any] $\frac1{2\pi}\sqrt{g/\delta}$.
:::
:::

::: part
answer: 20*log(sqrt(1 + (2*z*f/(1/(2*pi)*sqrt(9.81/(d*1e-3))))^2)/sqrt((1 - (f/(1/(2*pi)*sqrt(9.81/(d*1e-3))))^2)^2 + (2*z*f/(1/(2*pi)*sqrt(9.81/(d*1e-3))))^2))
unit: dB
tolerance: 0.5%

### What is its transmissibility in decibels (negative means isolation)?

::: misses
- [any] $20\log T$ with $r = f/f_0$.
:::
:::
:::

::: check
kind: parts
given: f = 20 | 30 | 60; r = 3 | 4

## A machine runs at {f} Hz, and its mount should place the disturbance at {r} times the natural frequency.

::: part
answer: f/r
unit: Hz
tolerance: 0.5%

### What natural frequency should the mount have?

::: misses
- [any] f/r.
:::
:::

::: part
answer: 9.81/(2*pi*f/r)^2*1000
unit: mm
tolerance: 0.5%

### What static deflection does that require?

::: misses
- [9.81/(f/r)^2*1000] Use $\omega_0 = 2\pi f_0$: $\delta = g/\omega_0^2$.
- [any] $\delta = g/(2\pi f_0)^2$.
:::
:::
:::

::: check
kind: parts
given: r = 0.5 | 1 | 1.414; z = 0.2 | 0.35 | 0.5

## A mount with damping ratio {z} is driven at {r} times its natural frequency.

::: part
answer: sqrt(1 + (2*z*r)^2)/sqrt((1 - r^2)^2 + (2*z*r)^2)
tolerance: 0.5%

### What is its transmissibility?

::: misses
- [1/sqrt((1 - r^2)^2 + (2*z*r)^2)] For force transmitted through a damped mount, include the damper's force: the numerator is $\sqrt{1 + (2\zeta r)^2}$.
- [any] $\sqrt{1 + (2\zeta r)^2}/\sqrt{(1 - r^2)^2 + (2\zeta r)^2}$.
:::
:::
:::

::: check
kind: parts
given: u = 0.02 | 0.05 | 0.1; f = 1.5 | 4 | 10

## A structure with a resonance at {f} Hz gets a tuned mass damper of mass ratio {u}.

::: part
answer: f/(1 + u)
unit: Hz
tolerance: 0.5%

### To what frequency should it be tuned?

::: misses
- [f] Den Hartog tunes slightly below the structure: $f_0/(1 + \mu)$.
- [any] $f_0/(1 + \mu)$.
:::
:::

::: part
answer: sqrt(3*u/(8*(1 + u)^3))
tolerance: 0.5%

### What damping ratio should it have?

::: misses
- [any] $\sqrt{3\mu/[8(1 + \mu)^3]}$.
:::
:::
:::

::: check
kind: parts
given: r = 5 | 10 | 30

## Well above resonance with negligible damping, compare a single-stage mount with a two-stage mount whose two resonances both sit near the same frequency, at {r} times it.

::: part
answer: 20*log(1/(r^2 - 1))
unit: dB
tolerance: 0.5%

### What transmissibility does the single stage give, in decibels?

::: misses
- [any] $1/(r^2 - 1)$ without damping.
:::
:::

::: part
answer: 20*log(1/r^4)
unit: dB
tolerance: 1%

### Roughly what does the two-stage mount give (falling as $1/r^4$)?

::: misses
- [any] $1/r^4$: twice the decibels.
:::
:::
:::

::: check
kind: choice

## Why does adding damping to a mount make its isolation worse well above resonance?

- [ ] Damping makes the spring stiffer
- [x] The damper's force grows with velocity, so at high frequency it transmits force to the foundation that the spring alone would not, and transmissibility falls only as 2ζ/r instead of 1/r²
- [ ] Damping raises the natural frequency
- [ ] Damping adds mass to the machine

::: misses
- [1] Damping and stiffness are separate.
- [3] It barely changes the natural frequency.
- [4] It adds no mass.
:::
:::

::: check
kind: derivation
vars: d = 0.0005..0.05, f = 5..200, z = 0..0.5

## A machine running at f Hz sits on a mount that deflects δ meters under its weight, with damping ratio ζ.

::: step
answer: 1/(2*pi)*sqrt(9.81/d)

### What is the mount's natural frequency?
:::

::: step
answer: sqrt(1 + (2*z*f/(1/(2*pi)*sqrt(9.81/d)))^2)/sqrt((1 - (f/(1/(2*pi)*sqrt(9.81/d)))^2)^2 + (2*z*f/(1/(2*pi)*sqrt(9.81/d)))^2)

### What is its transmissibility?
:::

::: right
Right. The mount's design is the choice of δ: the deflection fixes the frequency, and the frequency ratio fixes the isolation.
:::
:::

::: explain
## Why does a vibration mount only isolate above √2 times its natural frequency, and amplify below it?

::: model
Below resonance the spring is stiff compared with the mass's inertia, so the mass moves along with the force and the spring passes it straight on; near resonance the spring and mass exchange energy, motion builds up, and the spring passes on more force than was applied. Above resonance the mass's inertia dominates: it barely moves in response to a fast force, so the spring is hardly compressed and little force reaches the foundation. The crossover, where the transmitted force equals the applied force regardless of damping, falls at √2 times the natural frequency, so a mount has to be soft enough to put its resonance well below the disturbance.
:::
:::

::: practice
::: check
given: d = 2 | 10; f = 25 | 60
answer: f/(1/(2*pi)*sqrt(9.81/(d*1e-3)))
tolerance: 0.5%

## Frequency ratio: {f} Hz on a mount deflecting {d} mm?

::: misses
- [any] $f/f_0$ with $f_0 = \frac1{2\pi}\sqrt{g/\delta}$.
:::
:::

::: check
given: r = 3 | 8; z = 0.05 | 0.2
answer: sqrt(1 + (2*z*r)^2)/sqrt((1 - r^2)^2 + (2*z*r)^2)
tolerance: 0.5%

## Transmissibility: r = {r}, ζ = {z}?

::: misses
- [any] $\sqrt{1 + (2\zeta r)^2}/\sqrt{(1 - r^2)^2 + (2\zeta r)^2}$.
:::
:::

::: check
given: u = 0.01 | 0.02 | 0.03 | 0.05 | 0.08 | 0.1
answer: sqrt(3*u/(8*(1 + u)^3))
tolerance: 0.5%

## Den Hartog damping for μ = {u}?

::: misses
- [any] $\sqrt{3\mu/[8(1 + \mu)^3]}$.
:::
:::
:::