S16 · Lesson 27 · Waveguides and room modes

Cross modes and cutoff frequencies in rectangular and circular ducts, dispersion above cutoff, the standing-wave modes of a rectangular room, how many modes lie below a frequency, and the Schroeder frequency above which a room behaves statistically

A small room makes some bass notes boom and others vanish, depending on where you sit. Below a few hundred hertz, sound in a room is a set of distinct standing waves, the modes of a three-dimensional box, just as the microwave cavities of S5 have modes. Each mode has its own frequency and its own pattern of loud and quiet spots. Ducts have the same mathematics in two dimensions: below a cutoff only plane waves travel, which is why the muffler theory of lesson 25 works, and above it cross modes join in.

  • The number of room modes below frequency f in a rectangular room, from Weyl's estimate N≈4πVf33c3+πSf24c2+Lf8c (V the volume, S the total surface area, L the total edge length).
  • At low frequencies modes are sparse and each one stands out; the count grows as f³, so above a few hundred hertz they overlap into a smooth response.
  • Small rooms have few modes in the bass, which is why they sound uneven there.

Predict

A room is 5 m × 4 m × 3 m. What's its lowest mode?

Name it

Ducts

In a rigid rectangular duct of width a and height b, sound can travel in modes with m and n half-wavelengths across. Mode (m, n) propagates only above its cutoff

fmn=c2(ma)2+(nb)2

The plane wave (0, 0) always propagates; the first cross mode starts at c/2a for the widest side. In a circular duct of radius a the first cross mode starts at 1.841c/2πa. Above cutoff, a mode's energy travels at the group velocity c1−(fc/f)2.

Room modes

A rigid rectangular room Lx×Ly×Lz has modes at

f=c2(nxLx)2+(nyLy)2+(nzLz)2

Axial modes have one nonzero index, tangential two, oblique three. Every mode has a pressure maximum in every corner, which is why bass is loudest there.

Mode density and the Schroeder frequency

The number of modes below f grows as 4πVf3/3c3 plus surface and edge corrections. Above the Schroeder frequency,

fS≈2000T60/V

(T₆₀ the reverberation time in seconds, lesson 33), modes overlap enough that the room behaves statistically; below it, individual modes dominate and placement matters.

Worked example

How many modes does the 5 × 4 × 3 m room have below 100 Hz? What's its Schroeder frequency with T₆₀ = 0.5 s?

Show the solution
  1. Weyl's estimate. From the volume, surface and edge terms: N≈6.2+6.3+1.7=14.3 Counting exactly gives 13.
  2. Schroeder frequency. With V = 60 m³: fS=20000.5/60=183Hz Below that, the bass is shaped by individual room modes.

Answer 13 modes below 100 Hz (Weyl's estimate gives 14.3), and a Schroeder frequency of 183 Hz.

Worked example

A ventilation duct is 30 cm wide. Where does its first cross mode start? And a circular duct 15 cm in radius? How fast does the rectangular duct's (1,0) mode carry energy at 700 Hz?

Show the solution
  1. Rectangular duct. fc=c/2a=343/0.6=572Hz
  2. Circular duct. fc=1.841×3432π×0.15=670Hz
  3. Group velocity at 700 Hz. cg=3431−(572/700)2=198m/s
  4. Below cutoff. At 500 Hz the (1,0) mode doesn't propagate at all, so only the plane wave carries sound down the duct.

Answer the first cross mode starts at 572 Hz in the rectangular duct and 670 Hz in the circular one, and at 700 Hz the (1,0) mode carries energy at 198 m/s.

Worked example

How many room modes fall per hertz at 50 Hz in a 60 m³ studio and in a 20,000 m³ concert hall, and how far apart are they on average?

Show the solution
  1. Modal density. dNdf=4πVf2c3
  2. The studio. dNdf=4π×60×5023433=0.047per Hz one mode every 21 Hz, so individual modes boom at isolated frequencies.
  3. The hall. dNdf=4π×20,000×5023433=15.6per Hz one every 0.064 Hz, so the response is smooth.
  4. What follows. Small rooms therefore need bass traps and careful placement, while large ones are governed by statistical acoustics from very low frequencies up.

Answer 0.047 modes per hertz in the studio, one every 21 Hz, and 15.6 per hertz in the hall, one every 0.064 Hz.

Check

A room is 4 × 3 × 3 m. What's the frequency of mode (2, 0, 0)?

Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.

Check

The longest dimension of a room is 6 m. What's its lowest mode?

Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.

Check

A rectangular duct is 0.3 m across at its widest, carrying gas with c = 343 m/s. Where does its first cross mode cut on?

Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.

Check

What's the first cross-mode cutoff of a circular duct 0.15 m in radius, in air?

Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.

Check

Using only the leading term of Weyl's formula, about how many modes does a 200 m³ room have below 100 Hz?

Check

A room of 30 m³ has a reverberation time of 0.8 s. What's its Schroeder frequency?

Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.

Check

A room of 200 m³ at 40 Hz (c = 343 m/s).

(a)

What is its modal density, in modes per hertz?

(b)

What is the average spacing between modes?

Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.

Check

A rectangular room measures x × y × z meters (c = 343 m/s).

Step 1

What is the frequency of mode (a, b, d)?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why do small rooms have uneven bass while large halls don't?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.