title: Waveguides and room modes
heading: Cross modes and cutoff frequencies in rectangular and circular ducts, dispersion above cutoff, the standing-wave modes of a rectangular room, how many modes lie below a frequency, and the Schroeder frequency above which a room behaves statistically
eyebrow: S16 · Lesson 27 · Waveguides and room modes
xp: 50
---

::: hook
A small room makes some bass notes boom and others vanish, depending on where you sit. Below a few hundred hertz, sound in a room is a set of distinct standing waves, the modes of a three-dimensional box, just as the microwave cavities of S5 have modes. Each mode has its own frequency and its own pattern of loud and quiet spots. Ducts have the same mathematics in two dimensions: below a cutoff only plane waves travel, which is why the muffler theory of lesson 25 works, and above it cross modes join in.
:::

::: play
- The number of room modes below frequency f in a rectangular room, from Weyl's estimate $N \approx \frac{4\pi Vf^3}{3c^3} + \frac{\pi Sf^2}{4c^2} + \frac{Lf}{8c}$ (V the volume, S the total surface area, L the total edge length).
- At low frequencies modes are sparse and each one stands out; the count grows as f³, so above a few hundred hertz they overlap into a smooth response.
- Small rooms have few modes in the bass, which is why they sound uneven there.
:::

```sim plot
view: graph
x: f = 20..500 log
y: N = 0.1..2000 log
slider: x = 2..12 step 0.1 = 5
slider: y = 2..10 step 0.1 = 4
slider: z = 2..6 step 0.1 = 3
plot: 4*pi*x*y*z*f^3/(3*343^3) + pi*2*(x*y + y*z + x*z)*f^2/(4*343^2) + 4*(x + y + z)*f/(8*343) | samples: 300 | label: modes below f
readout: lowest mode, Hz = 343/(x + (y + z + abs(y - z))/2 + abs(x - (y + z + abs(y - z))/2)) | digits: 4
```

::: predict
## A room is 5 m × 4 m × 3 m. What's its lowest mode?

- [ ] 20 Hz
- [x] About 34 Hz
- [ ] About 57 Hz
- [ ] About 79 Hz

::: reveal
The lowest mode is the axial mode along the longest dimension: half a wavelength fits 5 m, so f = 343/(2 × 5) = 34.3 Hz. The next are 42.9 Hz along the 4 m side, 54.9 Hz for the (1,1,0) tangential mode, and 57.2 Hz along the height.
:::
:::

::: nameit
## Ducts

In a rigid rectangular duct of width a and height b, sound can travel in modes with $m$ and $n$ half-wavelengths across. Mode (m, n) propagates only above its **cutoff**

$$f_{mn} = \frac{c}{2}\sqrt{\left(\frac{m}{a}\right)^2 + \left(\frac{n}{b}\right)^2}$$

The plane wave (0, 0) always propagates; the first cross mode starts at c/2a for the widest side. In a circular duct of radius a the first cross mode starts at $1.841c/2\pi a$. Above cutoff, a mode's energy travels at the group velocity $c\sqrt{1 - (f_c/f)^2}$.

## Room modes

A rigid rectangular room $L_x \times L_y \times L_z$ has modes at

$$f = \frac{c}{2}\sqrt{\left(\frac{n_x}{L_x}\right)^2 + \left(\frac{n_y}{L_y}\right)^2 + \left(\frac{n_z}{L_z}\right)^2}$$

**Axial** modes have one nonzero index, **tangential** two, **oblique** three. Every mode has a pressure maximum in every corner, which is why bass is loudest there.

## Mode density and the Schroeder frequency

The number of modes below f grows as $4\pi Vf^3/3c^3$ plus surface and edge corrections. Above the **Schroeder frequency**,

$$f_S \approx 2000\sqrt{T_{60}/V}$$

(T₆₀ the reverberation time in seconds, lesson 33), modes overlap enough that the room behaves statistically; below it, individual modes dominate and placement matters.
:::

::: example
## How many modes does the 5 × 4 × 3 m room have below 100 Hz? What's its Schroeder frequency with T₆₀ = 0.5 s?

::: solution
1. **Weyl's estimate.** From the volume, surface and edge terms:
   $$\begin{aligned} N &\approx 6.2 + 6.3 + 1.7 \\ &= 14.3 \end{aligned}$$
   Counting exactly gives 13.
2. **Schroeder frequency.** With V = 60 m³:
   $$\begin{aligned} f_S &= 2000\sqrt{0.5/60} \\ &= 183\ \text{Hz} \end{aligned}$$
   Below that, the bass is shaped by individual room modes.

**Answer:** 13 modes below 100 Hz (Weyl's estimate gives 14.3), and a Schroeder frequency of 183 Hz.
:::
:::

::: example
## A ventilation duct is 30 cm wide. Where does its first cross mode start? And a circular duct 15 cm in radius? How fast does the rectangular duct's (1,0) mode carry energy at 700 Hz?

::: solution
1. **Rectangular duct.**
   $$\begin{aligned} f_c &= c/2a \\ &= 343/0.6 \\ &= 572\ \text{Hz} \end{aligned}$$
2. **Circular duct.**
   $$\begin{aligned} f_c &= \frac{1.841 \times 343}{2\pi \times 0.15} \\ &= 670\ \text{Hz} \end{aligned}$$
3. **Group velocity at 700 Hz.**
   $$\begin{aligned} c_g &= 343\sqrt{1 - (572/700)^2} \\ &= 198\ \text{m/s} \end{aligned}$$
4. **Below cutoff.** At 500 Hz the (1,0) mode doesn't propagate at all, so only the plane wave carries sound down the duct.

**Answer:** the first cross mode starts at 572 Hz in the rectangular duct and 670 Hz in the circular one, and at 700 Hz the (1,0) mode carries energy at 198 m/s.
:::
:::

::: example
## How many room modes fall per hertz at 50 Hz in a 60 m³ studio and in a 20,000 m³ concert hall, and how far apart are they on average?

::: solution
1. **Modal density.**
   $$\frac{dN}{df} = \frac{4\pi Vf^2}{c^3}$$
2. **The studio.**
   $$\begin{aligned} \frac{dN}{df} &= \frac{4\pi \times 60 \times 50^2}{343^3} \\ &= 0.047\ \text{per Hz} \end{aligned}$$
   one mode every 21 Hz, so individual modes boom at isolated frequencies.
3. **The hall.**
   $$\begin{aligned} \frac{dN}{df} &= \frac{4\pi \times 20{,}000 \times 50^2}{343^3} \\ &= 15.6\ \text{per Hz} \end{aligned}$$
   one every 0.064 Hz, so the response is smooth.
4. **What follows.** Small rooms therefore need bass traps and careful placement, while large ones are governed by statistical acoustics from very low frequencies up.

**Answer:** 0.047 modes per hertz in the studio, one every 21 Hz, and 15.6 per hertz in the hall, one every 0.064 Hz.
:::
:::

::: check
given: x = 4 | 6; y = 3 | 4.5; z = 2.5 | 3; a = 1 | 2; b = 0 | 1; d = 0 | 1
answer: 343/2*sqrt((a/x)^2 + (b/y)^2 + (d/z)^2)
unit: Hz
tolerance: 0.5%

## A room is {x} × {y} × {z} m. What's the frequency of mode ({a}, {b}, {d})?

::: right
Right. $\frac{c}{2}\sqrt{\sum(n_i/L_i)^2}$ = {answer} Hz.
:::

::: misses
- [343*sqrt((a/x)^2 + (b/y)^2 + (d/z)^2)] Each index counts half wavelengths: there's a factor of 1/2.
- [any] Not yet. The rectangular room's mode formula.
:::
:::

::: check
given: L = 3 | 6 | 12
answer: 343/(2*L)
unit: Hz
tolerance: 0.5%

## The longest dimension of a room is {L} m. What's its lowest mode?

::: right
Right. $c/2L$ = {answer} Hz.
:::

::: misses
- [343/(4*L)] Both walls are rigid: half a wavelength fits between them.
- [any] Not yet. The lowest axial mode.
:::
:::

::: check
given: a = 0.1 | 0.3 | 0.6; c = 343 | 480
answer: c/(2*a)
unit: Hz
tolerance: 0.5%

## A rectangular duct is {a} m across at its widest, carrying gas with c = {c} m/s. Where does its first cross mode cut on?

::: right
Right. $c/2a$ = {answer} Hz.
:::

::: misses
- [any] Not yet. Half a wavelength across the widest side.
:::
:::

::: check
given: a = 0.05 | 0.15 | 0.4
answer: 1.841*343/(2*pi*a)
unit: Hz
tolerance: 0.5%

## What's the first cross-mode cutoff of a circular duct {a} m in radius, in air?

::: right
Right. $1.841c/2\pi a$ = {answer} Hz.
:::

::: misses
- [343/(4*a)] Circular ducts use the Bessel-function zero 1.841.
- [any] Not yet. $f = 1.841c/(2\pi a)$.
:::
:::

::: check
given: V = 50 | 200 | 2000; f = 100 | 300
answer: 4*pi*V*f^3/(3*343^3)
tolerance: 0.5%

## Using only the leading term of Weyl's formula, about how many modes does a {V} m³ room have below {f} Hz?

::: right
Right. $4\pi Vf^3/3c^3$ = {answer}.
:::

::: misses
- [any] Not yet. The volume term of the mode count.
:::
:::

::: check
given: T = 0.3 | 0.8 | 2; V = 30 | 300 | 10000
answer: 2000*sqrt(T/V)
unit: Hz
tolerance: 0.5%

## A room of {V} m³ has a reverberation time of {T} s. What's its Schroeder frequency?

::: right
Right. $2000\sqrt{T_{60}/V}$ = {answer} Hz.
:::

::: misses
- [2000*T/V] Take the square root of the ratio.
- [any] Not yet. Schroeder's formula.
:::
:::

::: check
kind: parts
given: V = 30 | 200 | 5000; f = 40 | 100 | 250

## A room of {V} m³ at {f} Hz (c = 343 m/s).

::: part
answer: 4*pi*V*f^2/343^3
tolerance: 0.5%

### What is its modal density, in modes per hertz?

::: misses
- [4*pi*V*f^3/(3*343^3)] That's the number of modes below f; differentiate for the density.
- [any] $4\pi Vf^2/c^3$.
:::
:::

::: part
answer: 343^3/(4*pi*V*f^2)
unit: Hz
tolerance: 0.5%

### What is the average spacing between modes?

::: misses
- [any] One over the density.
:::
:::
:::

::: check
kind: derivation
vars: x = 2..30, y = 2..30, z = 2..10, a = 0..3, b = 0..3, d = 0..3

## A rectangular room measures x × y × z meters (c = 343 m/s).

::: step
answer: 343/2*sqrt((a/x)^2 + (b/y)^2 + (d/z)^2)

### What is the frequency of mode (a, b, d)?
:::

::: step
answer: 343/(2*x)

### What is the lowest mode along the x dimension?
:::

::: right
Right. Each axial mode fits a half wavelength across the room.
:::
:::

::: explain
## Why do small rooms have uneven bass while large halls don't?

::: model
At low frequencies a room's response is the sum of its modes, and a small room has only a few of them below a couple of hundred hertz, spread tens of hertz apart. A bass note near a mode is reinforced strongly, one between modes is weak, and each mode's standing-wave pattern makes the level change with position, so some notes boom and others disappear depending on where you sit. The number of modes grows with the room's volume and as the cube of frequency, so in a large hall the modes are packed so closely, overlapping within their bandwidths, that no single mode stands out and the response is smooth, the statistical regime above the Schroeder frequency.
:::
:::

::: practice

::: check
given: x = 3 | 15; y = 2.5 | 10; z = 2.2 | 6; a = 0 | 3; b = 1 | 2; d = 0 | 2
answer: 343/2*sqrt((a/x)^2 + (b/y)^2 + (d/z)^2)
unit: Hz
tolerance: 0.5%

## Mode ({a}, {b}, {d}) of a {x} × {y} × {z} m room?

::: misses
- [any] $\frac{c}{2}\sqrt{\sum(n/L)^2}$.
:::
:::

::: check
given: a = 0.02 | 1; c = 340 | 600
answer: c/(2*a)
unit: Hz
tolerance: 0.5%

## Duct cutoff: {a} m, c = {c}?

::: misses
- [any] c/2a.
:::
:::

::: check
given: T = 0.2 | 4; V = 10 | 50000
answer: 2000*sqrt(T/V)
unit: Hz
tolerance: 0.5%

## Schroeder frequency: {T} s, {V} m³?

::: misses
- [any] $2000\sqrt{T/V}$.
:::
:::
:::