S2 · Lesson 26 · Low-dropout regulators
Pass devices, a load-dependent output pole, ESR zeros and supply rejection
Every chip with analog circuits has linear regulators on it: they turn a noisy battery or switcher output into a quiet, steady supply. A low-dropout regulator (LDO) is a feedback amplifier whose output transistor carries the whole load current, which makes it an unusual one to stabilize: its output pole moves by orders of magnitude as the load changes from microamps to hundreds of milliamps, and the output capacitor's own series resistance often decides whether it's stable. This lesson analyzes the loop, the dropout, and how well it rejects ripple on its input.
- The line is the output pole of an LDO, , against load current on log axes: it moves a decade for every decade of load.
- The dashed line is the zero from the output capacitor's equivalent series resistance, , fixed by the capacitor.
- Many LDOs rely on that zero to cancel a pole near crossover. Change the ESR and watch where the zero lands relative to the pole's range.
Predict
An LDO's load steps from 0 to 100 mA. Before its loop reacts, about 1 µs, the 1 µF output capacitor supplies the current. How far does the output dip?
V, plus the ESR's own step . A faster loop or a larger capacitor shrinks the dip; on-chip LDOs with no external capacitor need loops fast enough to respond in nanoseconds.
Name it
The circuit
An error amplifier compares a divided-down output with a reference and drives the gate of a PMOS pass transistor between the input and the output. A PMOS can be driven to the input rail's full , so the regulator works until falls to the pass device's : the dropout.
Efficiency
At most (ignoring quiescent current): the difference times the load current is heat.
The loop
The output pole , with , moves with load, while the error amplifier's pole sits at its own output node. The capacitor's ESR adds a zero at . Designs either make the output pole dominant (a large output capacitor) or the amplifier's pole dominant and use the ESR zero or internal compensation to keep phase margin across the whole load range.
Regulation and rejection
Load regulation: the open-loop output resistance divided by . Supply rejection: at low frequency about the loop gain; above the loop's bandwidth the input couples straight through the pass device, so PSRR falls to the ratio set by the output capacitor and the pass device's impedance.
Worked example
An LDO turns 3.3 V into 2.5 V at 100 mA, through a pass transistor of 1 Ω on-resistance. What are its efficiency, its heat and its dropout?
Show the solution
- Efficiency. At most
- Heat. The pass device dissipates
- Dropout. so it regulates down to = 2.6 V.
- Compared with a switcher. A switcher would be more efficient; the LDO is quieter and has no ripple of its own.
Answer at most 75.8% efficiency, 80 mW of heat in the pass device, and 0.1 V of dropout, so it regulates down to 2.6 V in.
Worked example
With 1 µF at the 2.5 V output and 0.1 Ω of ESR, where are the output pole at 100 mA and at 1 mA, and the ESR zero?
Show the solution
- Pole at 100 mA. Here = 25 Ω:
- Pole at 1 mA. Here = 2.5 kΩ, so the pole is at 64 Hz.
- ESR zero.
- Why it's hard. A hundredfold load change moves the output pole a hundredfold: the central difficulty of LDO compensation.
Answer the output pole is at 6.4 kHz at 100 mA and 64 Hz at 1 mA, and the ESR zero is at 1.6 MHz.
Worked example
The pass device and divider give 2 Ω of open-loop output resistance, and the loop gain is 1000. What is the load regulation, and the output change for a 100 mA step after the loop settles?
Show the solution
- Load regulation.
- A 100 mA step.
- PSRR. The PSRR at low frequency is about the same 60 dB of loop gain.
Answer the load regulation is 2.0 mΩ, so a 100 mA step moves the output by 0.20 mV.
Check
An LDO turns 3.3 V into 1.8 V at 500 mA.
(a)
What is its best efficiency?
(b)
What does its pass device dissipate?
Write units the way you normally would: 1.5 mW, 1500 µW and 0.0015 W are the same answer.
Check
A pass device has 0.5 Ω on-resistance and carries 50 mA for a 3.3 V output.
(a)
What is the dropout?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What is the lowest input that keeps regulation?
Check
An LDO's 3.3 V output has 1 µF with 1 Ω of ESR, at 1 mA load.
(a)
Where is the output pole?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
(b)
Where is the ESR zero?
Check
A load steps by 100 mA; the loop takes 0.1 µs to respond, and the output capacitor is 22 µF with 0.1 Ω ESR.
(a)
How far does the capacitor's charge sag before the loop responds?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
(b)
What instant step does the ESR add?
Check
An LDO's open-loop output resistance is 2 Ω and its loop gain 100.
(a)
What is its closed-loop output resistance?
Write units the way you normally would: 1.5 mΩ, 1500 µΩ and 0.0015 Ω are the same answer.
(b)
How much does the output move for a 100 mA load change?
Check
An LDO is stable with a tantalum capacitor (high ESR) but oscillates when a ceramic capacitor of the same value (tiny ESR) is fitted. Why?
Check
An LDO's output is V with capacitor C of series resistance E, at load I.
Step 1
Where is the output pole (Hz)?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
Where is the ESR zero (Hz)?
Step 3
What is their ratio, zero over pole?
Check
Write ldo_loop(f, A0, fa, IL, Vout, Cout, ESR): the loop gain magnitude and phase (degrees) at frequency f of an LDO modeled as a DC gain A0, an amplifier pole at fa, an output pole at and an ESR zero. Then phase_margin(A0, fa, IL, Vout, Cout, ESR): find the unity-gain frequency by bisection in log f (1 Hz to 1 GHz) and return 180° plus the phase there.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Explain why
Why does an LDO's output pole move with load current, and why does that make it harder to stabilize than an ordinary op amp?
The output node's resistance is mostly the load itself, the output voltage divided by the load current, in parallel with the pass device's output resistance. Its capacitance is the output capacitor. So the pole is proportional to load current, and across a range from microamps to hundreds of milliamps it moves by five orders of magnitude. An ordinary op amp's poles stay put, so one compensation fits all conditions. In an LDO the compensation must leave enough phase margin whether the output pole sits far below the amplifier's pole or close to it, which usually means either making the output pole dominant with a large capacitor or relying on the capacitor's ESR zero, and checking stability at both load extremes.
Practice
Keep practicing
8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.