S2 · Lesson 32 · Sensor front ends
Bridges, capacitive sensing and noise matching: getting a weak sensor signal into an ADC intact
A strain gauge changes its resistance by a part in a thousand; a MEMS accelerometer's capacitance changes by femtofarads; a thermocouple gives tens of microvolts per degree. The circuits of lessons 29 to 31, low-noise amplification and chopping, exist to read signals like these. This lesson puts them to work: how a bridge turns a tiny resistance change into a voltage, how a charge amplifier reads a capacitance, why measuring ratiometrically against the excitation removes the excitation's own drift, and how to choose an amplifier whose noise matches the sensor's impedance.
- The noise figure of an amplifier with input voltage noise = 4 nV/√Hz and current noise against source resistance , at 300 K: .
- Voltage noise dominates for small sources, current noise for large ones. The minimum sits at , where .
Predict
A quarter-bridge strain gauge (gauge factor 2, 350 Ω) with 5 V excitation sees 1000 microstrain. About what output does the bridge give?
The gauge's resistance changes by , and a quarter bridge outputs = = 2.5 mV. Four active gauges in a full bridge give four times as much, 10 mV, and cancel temperature effects too. Either way the signal is millivolts riding on a 2.5 V common mode, a job for an instrumentation amplifier.
Name it
Resistive bridges
A Wheatstone bridge excited by with one active element gives, for small ,
The output is proportional to the excitation, so a drifting excitation looks like a changing signal. Ratiometric measurement feeds the same excitation to the ADC's reference: the ADC's code is then , and the excitation cancels.
Capacitive sensors
A sensor capacitance changing by under an excitation step moves a charge ; a charge amplifier with feedback capacitor turns that into . Switched versions of this, capacitance-to-digital converters, resolve attofarads. Shields driven at the sensor's potential (guarding) keep cable capacitance out of the measurement.
Noise matching
An amplifier with input voltage noise and current noise , fed by a source whose own noise is , has noise factor
minimized at with . Bipolar inputs have low and higher , suiting low-impedance sources such as bridges and thermocouples; JFET and CMOS inputs have tiny , suiting high-impedance sources such as photodiodes and piezoelectric sensors. A transformer can scale a source's impedance toward .
Low-frequency errors
Below a few hertz, 1/f noise and offset drift dominate, which is why sensor amplifiers chop or auto-zero (lesson 31), and why bridges are sometimes excited with AC and demodulated.
Worked example
A 350 Ω strain gauge with gauge factor 2 sees 1000 µε in a quarter bridge with 5 V excitation. Find the output, and compare a full bridge.
Show the solution
- Fractional change. Gauge factor times strain gives .
- Quarter bridge.
- Full bridge. Four active arms give four times as much, 10 mV.
- Arm current.
- Self-heating. Each gauge heats by Higher excitation raises the signal but self-heating limits it, which is why ratiometric measurement and high gain are preferred to more volts.
Answer the quarter bridge gives 2.5 mV and a full bridge 10 mV.
Worked example
An amplifier has = 4 nV/√Hz and = 1 pA/√Hz. What source resistance gives the lowest noise figure, and what is it?
Show the solution
- Optimum source resistance.
- Thermal energy. The minimum noise factor is , with
- Minimum noise figure. a noise figure of 1.71 dB.
- From a 350 Ω bridge. The voltage noise dominates and the noise figure is higher, though the absolute noise, about 4.7 nV/√Hz in total with the bridge's own thermal noise, is still excellent.
Answer a 4 kΩ source gives the lowest noise figure, 1.71 dB (F = 1.48).
Worked example
A MEMS sensor's capacitance changes by 10 fF. With a 3.3 V excitation step and a 1 pF feedback capacitor, what does the charge amplifier output? What feedback capacitor gives 100 mV?
Show the solution
- Output for 10 fF.
- Feedback capacitor for 100 mV.
- The cost. Smaller feedback capacitors give more gain but more sensitivity to their own parasitics and to the amplifier's noise gain, .
Answer the output is 33 mV, and a 0.33 pF feedback capacitor gives 100 mV.
Check
A bridge with 4 active strain gauges (gauge factor 2, arranged to add) sees 100 µε with 10 V excitation. What is its output?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
An amplifier has 4 nV/√Hz of voltage noise and 0.01 pA/√Hz of current noise. What source resistance minimizes its noise figure?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
What is the minimum noise figure, in dB, of an amplifier with 4 nV/√Hz and 0.01 pA/√Hz at 300 K?
Check
A capacitive sensor of 20 pF changes by 10 fF, read by a charge amplifier with a 2 pF feedback capacitor and a 1.8 V excitation step.
(a)
What output step does the change produce?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
(b)
What noise gain does the amplifier's own voltage noise see?
Check
A quarter bridge's active arm changes by a fraction 0.1. What is the exact output as a fraction of the excitation, ?
Check
Why does ratiometric measurement, using the bridge's excitation as the ADC's reference, remove excitation drift from the result?
Check
Pick an op amp for a sensor. With source resistance Rs = 350 Ω at 300 K, compute each amplifier's total input-referred noise density for these parts, given as (name, in nV/√Hz, in pA/√Hz): ('bipolar', 1, 2), ('jfet', 6, 0.003), ('cmos', 15, 0.0005), ('chopper', 20, 0.1). Set best to the name with the lowest total, and totals to a dict of totals in nV/√Hz.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Explain why
A load cell's reading drifts by 0.3% over an afternoon, and the drift tracks the room temperature. The bridge is excited from a 5 V regulator and read by an ADC with its own 2.5 V internal reference. Explain the likely cause and the fix.
The bridge output is proportional to its excitation, and the ADC compares it with an independent internal reference. If the 5 V regulator and the 2.5 V reference drift differently with temperature, the ratio between excitation and reference changes, and the reading changes with it, even though the load hasn't. A drift of 0.3% corresponds to a regulator and reference mismatch of a few tens of ppm per degree over ten or so degrees. The fix is ratiometric measurement: derive the ADC's reference from the same excitation (for example, through a divider), so the code depends only on the bridge's ratio. Self-heating of the gauges and the amplifier's offset drift can contribute too, which chopping and full-bridge temperature compensation address.
Practice
Keep practicing
8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.