S4 Computer architecture · Practice
Power, energy and the end of Dennard scaling
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
Each generation scales dimensions by √2, the voltage by 0.85 and the clock by 1. By what factor does power density grow per generation?
Check
After 3 generations at √2 per generation, voltage scaling 0.9 per generation and a fixed clock, what fraction of a fixed-power chip can run at full speed?
Check
A core runs at 2.5 GHz on 65 W, with power growing as the cube of frequency. What clock does a 150 W budget allow?
Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.
Check
All 8 cores share a power budget at 2.5 GHz. With only 4 active, each takes an equal share of the whole budget. What clock can they reach (power ∝ , no voltage cap)?
Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.
Check
A task of 2 billion cycles runs at 1.5 GHz and 0.9 V. Dynamic energy is 5 nJ per cycle at 1 V (scaling as ), and leakage is 15 W at 1 V (scaling as V). What energy does the task use?
Write units the way you normally would: 1.5 J, 1500 mJ and 0.0015 kJ are the same answer.
Check
Design A uses 20 J and takes 1 s per task; design B uses 60 J and 2 s. What's A's energy-delay product as a fraction of B's?
Check
A chip switches 1 nF at activity 0.1, at 1 V and 3 GHz, and leaks 1 W.
(a)
What is its dynamic power?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
What is its total power?
(c)
What dynamic energy does each cycle take?
Check
A 4-core chip runs all cores at 2.5 GHz within its power budget, with voltage tracking frequency so power goes as .
(a)
How fast can 2 active core(s) run on the same budget, ignoring voltage limits?
Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.
Check
Power-density growth per generation: v = 0.8, g = 1.05?
Check
Clock at 200 W, from 2 GHz at 50 W, power ∝ ?
Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.
Check
Task energy: 1 G cycles at 2 GHz, 1 V, 6 nJ/cycle at 1 V, 10 W leak at 1 V?
Write units the way you normally would: 1.5 J, 1500 mJ and 0.0015 kJ are the same answer.
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S4