title: Antenna arrays
heading: The array factor, broadside and endfire arrays, electronic beam steering, grating lobes, beam broadening and tapers
eyebrow: S5 · Lesson 32 · Antenna arrays
xp: 50
---

::: hook
One antenna has a fixed pattern. Several identical antennas fed with controlled amplitudes and phases have a pattern the designer chooses, and by changing the phases electronically, the beam can be steered in microseconds without moving anything. Phased arrays aim radar beams, form the beams of 5G base stations and satellite-internet terminals, and point radio telescopes. The mathematics is a sum of phasors, the array factor, and its consequences are concrete: more elements narrow the beam, too much spacing creates copies of the beam called grating lobes, and steering away from broadside widens the beam.
:::

::: play
- The array factor of N equally spaced, equally fed elements, in dB, against the angle from broadside, with the beam steered to angle $\theta_0$ by a progressive phase shift.
- Spacing above $\lambda/(1 + |\sin\theta_0|)$ lets a grating lobe, a full-strength copy of the main beam, into visible space. Try 0.9λ steered to 30°.
- The first sidelobes of a uniform array sit 13.3 dB below the beam whatever N is; more elements only narrow the beam.
:::
:::

```sim plot
view: graph
x: t = -90..90 °
y: A = -40..0 dB
slider: N = 2..32 step 1 = 8
slider: d = 0.2..1.5 = 0.5 step 0.01 λ
slider: s = -60..60 = 0 step 1 °
plot: 20*log(abs(sin(N*pi*d*(sin(t*pi/180) - sin(s*pi/180)) + 0.000001)/(N*sin(pi*d*(sin(t*pi/180) - sin(s*pi/180)) + 0.000001/N))) + 1e-9) | samples: 1500 | label: array factor, dB
readout: phase step between elements, ° = -360*d*sin(s*pi/180)
readout: largest spacing without grating lobes, λ = 1/(1 + abs(sin(s*pi/180)))
readout: half-power beamwidth, ° = 0.886/(N*d)*180/pi/cos(s*pi/180)
```

::: predict
## An 8-element array has λ/2 spacing. To steer its beam 30° from broadside, what phase step is needed between adjacent elements, and does a grating lobe appear?

- [ ] 30°, and yes
- [x] 90°, and no
- [ ] 180°, and yes
- [ ] 45°, and no

::: reveal
The phase step is $\beta = -kd\sin\theta_0$, magnitude $360° \times 0.5 \times \sin 30°$ = 90°. Grating lobes stay out of view as long as $d < \lambda/(1 + \sin\theta_0)$ = 0.667λ, and λ/2 is below that. The beam also widens by $1/\cos 30°$, from 12.7° to 14.7°, because the array looks shorter from that angle.
:::
:::

::: nameit
## The array factor

N identical elements along a line, spacing d, fed with equal amplitude and a progressive phase β. The total pattern is the element pattern times the **array factor**

$$\text{AF} = \sum_{n=0}^{N-1}e^{jn\psi} \;\Rightarrow\; |\text{AF}_n| = \left|\frac{\sin(N\psi/2)}{N\sin(\psi/2)}\right|, \qquad \psi = kd\sin\theta + \beta$$

with θ measured from broadside.

## Broadside, endfire and steering

- **Broadside** (β = 0): beam perpendicular to the array, directivity ≈ $2Nd/\lambda$, half-power beamwidth ≈ $0.886\frac{\lambda}{Nd}$ radians, null-to-null ≈ $2\arcsin\frac{\lambda}{Nd}$.
- **Steered** to $\theta_0$: $\beta = -kd\sin\theta_0$. The beam widens by $1/\cos\theta_0$.
- **Endfire** (beam along the axis, β = −kd): directivity ≈ $4Nd/\lambda$.

## Grating lobes

The array factor repeats every 2π in ψ. A grating lobe enters visible space when $d \ge \frac{\lambda}{1 + |\sin\theta_0|}$; its direction satisfies $\sin\theta_g = \sin\theta_0 \pm \lambda/d$. Arrays meant to scan to ±60° need d ≤ 0.54λ.

## Tapers

Uniform feeding gives the narrowest beam but −13.3 dB sidelobes. Tapering the amplitudes toward the ends (binomial for no sidelobes, Dolph–Chebyshev for equal sidelobes at a chosen level, Taylor for practical designs) lowers the sidelobes at the cost of a wider beam and lower directivity.
:::

::: example
## An 8-element, λ/2-spaced array: directivity, beamwidth at broadside and at 30° scan?

::: solution
1. **Directivity.**
   $$\begin{aligned} D &\approx 2 \times 8 \times 0.5 \\ &= 8 \end{aligned}$$
   or 9.0 dBi (times the element's own directivity).
2. **Beamwidth at broadside.**
   $$\begin{aligned} \theta_{3\text{dB}} &\approx \frac{0.886}{4}\ \text{rad} \\ &= 12.7° \end{aligned}$$
   The exact value is 12.8°.
3. **Beamwidth at 30° scan.**
   $$\begin{aligned} \theta_{3\text{dB}} &\approx \frac{12.7°}{\cos 30°} \\ &= 14.7° \end{aligned}$$
4. **Null-to-null.**
   $$2\arcsin\frac{1}{4} = 29.0°$$

**Answer:** the directivity is about 8 (9.0 dBi), and the beamwidth is 12.7° at broadside and 14.7° at 30° scan.
:::
:::

::: example
## The same array with 0.9λ spacing is steered to 30°. Where's the grating lobe?

::: solution
1. **Grating lobe direction.**
   $$\begin{aligned} \sin\theta_g &= \sin 30° - \frac{1}{0.9} \\ &= -0.611 \end{aligned}$$
   so $\theta_g$ = −37.7°: a second full-strength beam on the other side of broadside.
2. **Spacing limit.** The limit for 30° scanning is 0.667λ; wider spacing saves elements but only works for small scan angles.

**Answer:** the grating lobe sits at −37.7°.
:::
:::

::: example
## A 16-element linear array spaced λ/2 apart is fed uniformly at broadside. What directivity, beamwidth and first sidelobe does it have?

::: solution
1. **Directivity.**
   $$\begin{aligned} D &\approx \frac{2Nd}{\lambda} \\ &= 16 \end{aligned}$$
   or 12 dBi.
2. **Half-power beamwidth.**
   $$\begin{aligned} \theta_{3\text{dB}} &= \frac{0.886\lambda}{Nd} \\ &= \frac{0.886}{8} \\ &= 0.111\ \text{rad} \end{aligned}$$
   which is 6.3°.
3. **First sidelobe.** It sits 13.3 dB down, as for any uniform aperture; a taper lowers it at the cost of a wider beam.

**Answer:** a directivity of about 16 (12 dBi), a 6.3° beamwidth and a first sidelobe 13.3 dB down.
:::
:::

::: check
given: N = 4 | 16 | 64; d = 0.6 | 0.75
answer: 10*log(2*N*d)
unit: dBi
tolerance: 0.05

## A broadside array of {N} isotropic elements is spaced {d}λ apart. About what's its directivity?

::: right
Right. $10\log(2Nd/\lambda)$ = {answer} dBi.
:::

::: misses
- [10*log(N)] It depends on the array's length in wavelengths, $2Nd/\lambda$.
- [10*log(4*N*d)] That's the endfire value.
- [any] Not yet. $D \approx 2Nd/\lambda$.
:::
:::

::: check
given: d = 0.25 | 0.5 | 0.7; s = 10 | 30 | 50
answer: 360*d*sin(s*pi/180)
unit: °
tolerance: 0.5%

## Elements are spaced {d}λ apart. What phase step between neighbors steers the beam {s}° from broadside (magnitude)?

::: right
Right. $360° \times (d/\lambda)\sin\theta_0$ = {answer}°.
:::

::: misses
- [360*d*cos(s*pi/180)] θ is measured from broadside, so it's the sine.
- [any] Not yet. $|\beta| = kd\sin\theta_0$.
:::
:::

::: check
given: s = 20 | 45 | 60
answer: 1/(1 + sin(s*pi/180))
unit: λ
tolerance: 0.5%

## An array will scan up to {s}° from broadside. What's the largest element spacing that keeps grating lobes out of view?

::: right
Right. $\lambda/(1 + \sin\theta_0)$ = {answer}λ.
:::

::: misses
- [1/sin(s*pi/180)] The grating lobe sits at $\sin\theta_0 - \lambda/d$: it must stay below −1.
- [any] Not yet. Keep $\sin\theta_0 - \lambda/d < -1$.
:::
:::

::: check
given: N = 8 | 20 | 50; d = 0.5 | 0.6; s = 20 | 30 | 50
answer: 0.886/(N*d)*180/pi/cos(s*pi/180)
unit: °
tolerance: 0.5%

## A uniform array of {N} elements spaced {d}λ is steered {s}° from broadside. About what's its half-power beamwidth?

::: right
Right. $0.886\frac{\lambda}{Nd\cos\theta_0}$ = {answer}°.
:::

::: misses
- [0.886/(N*d)*180/pi] Steering widens the beam by $1/\cos\theta_0$.
- [any] Not yet. Broadside beamwidth over $\cos\theta_0$.
:::
:::

::: check
given: d = 1 | 1.5 | 2; s = 10 | 25
answer: asin(sin(s*pi/180) - 1/d)*180/pi
unit: °
tolerance: 0.5%

## An array spaced {d}λ apart is steered {s}° from broadside. Where's the grating lobe on the other side?

::: right
Right. $\arcsin(\sin\theta_0 - \lambda/d)$ = {answer}°.
:::

::: misses
- [any] Not yet. ψ repeats every 2π: shift $\sin\theta$ by λ/d.
:::
:::

::: check
given: N = 4 | 10; d = 0.5 | 0.75; t = 5 | 12
answer: 20*log(abs(sin(N*pi*d*sin(t*pi/180))/(N*sin(pi*d*sin(t*pi/180)))))
unit: dB
tolerance: 0.05

## A broadside array of {N} elements spaced {d}λ apart: how far below the beam is the array factor at {t}° from broadside?

::: right
Right. {answer} dB.
:::

::: misses
- [any] Not yet. Evaluate $\frac{\sin(N\psi/2)}{N\sin(\psi/2)}$ with $\psi = kd\sin\theta$.
:::
:::

::: check
kind: parts
given: N = 4 | 8 | 16 | 32; d = 0.5 | 0.7; t = 20 | 30 | 45

## An N-element array (N = {N}) spaced {d}λ is uniformly fed and steered {t}° from broadside.

::: part
answer: 2*N*d
tolerance: 0.5%

### About what directivity does it have?

::: misses
- [any] $2Nd/\lambda$.
:::
:::

::: part
answer: 0.886/(N*d)*180/pi/cos(t*pi/180)
unit: °
tolerance: 0.5%

### What is its half-power beamwidth when steered?

::: misses
- [0.886/(N*d)*180/pi] Steering widens the beam by $1/\cos\theta_0$.
- [any] $0.886\lambda/(Nd\cos\theta_0)$.
:::
:::
:::

::: check
kind: parts
given: d = 0.8 | 0.9 | 1; t = 30 | 45 | 60

## An array spaced {d}λ is steered {t}° from broadside.

::: part
answer: 1/(1 + sin(t*pi/180))
unit: λ
tolerance: 0.5%

### Above what spacing do grating lobes appear at this steering?

::: misses
- [any] $\lambda/(1 + |\sin\theta_0|)$.
:::
:::

::: part
answer: asin(sin(t*pi/180) - 1/d)*180/pi
unit: °
tolerance: 0.5%

### Where is the grating lobe?

::: misses
- [any] $\sin\theta_g = \sin\theta_0 - \lambda/d$.
:::
:::
:::

::: check
kind: derivation
vars: N = 2..256, d = 0.25..1, t = 0..1.2

## N elements spaced d wavelengths are steered t radians from broadside.

::: step
answer: 2*N*d

### What is the approximate directivity?
:::

::: step
answer: 0.886/(N*d*cos(t))

### What is the half-power beamwidth in radians?
:::

::: step
answer: 1/(1 + sin(t))

### Above what spacing, in wavelengths, does a grating lobe appear?
:::

::: right
Right. Wide scanning forces close spacing: at 60° the elements must be within 0.54λ.
:::
:::

::: explain
## Why does steering a phased array away from broadside widen its beam?

::: model
An array's beamwidth is set by how long it looks from the direction of the beam: the elements' contributions add in phase only within an angular range of about a wavelength divided by that length. Steered to broadside, the array presents its full length. Steered to an angle θ₀, the beam leaves the array obliquely, and the array's length projected perpendicular to the beam shrinks by cos θ₀, as if the array were shorter. A shorter aperture can't form as narrow a beam, so the beamwidth grows by 1/cos θ₀, and the gain falls with it. That's why flat phased arrays rarely scan beyond about 60°, and why some systems use several faces.
:::
:::

::: practice

::: check
given: d = 0.4 | 0.6; s = 15 | 40
answer: 360*d*sin(s*pi/180)
unit: °
tolerance: 0.5%

## Phase step: spacing {d}λ, steer {s}°?

::: misses
- [any] $360°(d/\lambda)\sin\theta_0$.
:::
:::

::: check
given: s = 15 | 30 | 45 | 55 | 60 | 70
answer: 1/(1 + sin(s*pi/180))
unit: λ
tolerance: 0.5%

## Largest spacing scanning to {s}°?

::: misses
- [any] $\lambda/(1 + \sin\theta_0)$.
:::
:::

::: check
given: N = 12 | 40; d = 0.5 | 0.7; s = 0 | 45
answer: 0.886/(N*d)*180/pi/cos(s*pi/180)
unit: °
tolerance: 0.5%

## Beamwidth: {N} elements, {d}λ, steered {s}°?

::: misses
- [any] $0.886\lambda/(Nd\cos\theta_0)$.
:::
:::
:::