S5 · Lesson 5 · Surface plasmons
Waves bound to a metal surface, shorter than light in air, and the sensors and optics built on them
Lesson 4 showed that below its plasma frequency a metal's permittivity is negative, so light reflects instead of entering. At the boundary between such a metal and a dielectric, something new can travel: a surface plasmon polariton, an electromagnetic wave locked to the oscillating electrons at the surface, decaying away on both sides. Its wavelength is shorter than light's in the dielectric, so ordinary light can't launch it by shining on a flat surface; it needs a prism or a grating to match the momentum. That mismatch, and the wave's extreme sensitivity to whatever touches the surface, make plasmons the basis of label-free biosensors used in every drug-discovery lab, and of optics that squeezes light below the diffraction limit.
- The effective index of a surface plasmon, , against the metal's (negative, real) permittivity, for a dielectric of permittivity .
- It's always larger than , the index of light in the dielectric, so a plasmon can't be excited by light arriving through that dielectric. It diverges as approaches : the surface plasma resonance.
Predict
A gold or silver film on a glass prism is used to excite surface plasmons on its far side, facing air. Why does the light have to come through the prism?
On the air side, , so no angle of incidence in air gives a tangential wavevector large enough. In glass of index 1.515, can match at one angle, and the light tunnels through the thin metal to excite the plasmon on the air side. This is the Kretschmann configuration; at the matching angle the reflected light dips sharply.
Name it
The surface plasmon polariton
At a flat boundary between a metal of permittivity (with ) and a dielectric , a TM wave can propagate along the surface with wavevector
Because is negative and larger in size than , : the plasmon is slower and shorter than light in the dielectric. Its field decays from the surface with 1/e depths
hundreds of nanometers into the dielectric and a few tens into the metal for visible light. The metal's loss (the imaginary part of ) limits how far it travels: micrometers to tens of micrometers.
Coupling light in
Light needs extra tangential wavevector to match :
- Prism (Kretschmann): light in a prism of index hits a thin metal film at angle θ with .
- Grating: a periodic surface of period Λ adds , so light can couple when .
Sensing
depends on , so a thin layer of molecules binding to the surface shifts the coupling angle. Surface plasmon resonance (SPR) instruments track that angle to a few millionths of a refractive-index unit, measuring how fast proteins bind without labels.
Values used here
This lesson takes silver at 633 nm as (ignoring its small imaginary part); gold at the same wavelength is about −11.
Worked example
For silver ( = −18) at 633 nm, find the plasmon index against air and against water ( = 1.77), and the plasmon's wavelength in air.
Show the solution
- Against air.
- Against water. against water's own index of 1.33.
- Plasmon wavelength on air. just 3% shorter than light's. The confinement is modest, which is why the field reaches far into the air.
Answer the plasmon index is 1.029 against air and 1.401 against water, and on air the plasmon's wavelength is 615 nm.
Worked example
Find the Kretschmann angle in a glass prism ( = 1.515) for the silver-air plasmon, and for the silver-water plasmon used in a biosensor.
Show the solution
- Silver-air plasmon. so θ = 42.8°.
- Silver-water plasmon. so θ = 67.6°.
- Sensitivity. A sensor in water works near 68°, and a molecular layer raising the effective index by 0.001 shifts the angle by about a tenth of a degree, easily measured with a camera across a fan of angles.
Answer 42.8° for the silver-air plasmon and 67.6° for the silver-water plasmon.
Worked example
How far does the silver-air plasmon's field reach into the air and into the silver at 633 nm?
Show the solution
- Scale length.
- Root factor.
- Reach into the air.
- Reach into the silver.
- What it means. The field lives mostly outside the metal, sampling about half a micrometer of whatever touches the surface: just the right scale for a layer of bound proteins.
Answer the field reaches 415 nm into the air and 23 nm into the silver.
Check
What is the effective index of a surface plasmon between a metal with = −18 and a dielectric with = 1?
Check
A Kretschmann sensor uses a prism of index 1.515 and a metal with = −18, with air beyond the film. At what angle does light in the prism couple to the plasmon?
Check
A plasmon on a metal with = −18 faces air at 633 nm.
(a)
How far does its field reach into the air (1/e)?
Write units the way you normally would: 1.5 nm, 1500 pm and 0.0015 µm are the same answer.
(b)
And into the metal?
Check
A metal grating of period 800 nm ( = −15) in air is lit at 785 nm. At what angle of incidence does the first diffraction order couple to the plasmon, ?
Check
A surface plasmon resonance biosensor detects proteins binding to its gold surface. What does the binding change?
Check
Show that a plasmon's effective index exceeds light's in the dielectric.
Step 1
Divide by . What ratio is left?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
Rewrite it as 1 plus something. (It's larger than 1 whenever .)
Check
Model an SPR sensor's sensitivity. With silver ( = −18) and a BK7 prism ( = 1.515), write angle(nd), the Kretschmann angle in degrees for a dielectric of index nd. Set theta at n = 1.34 and sens, the angle shift per refractive-index unit, from a central difference with step 1e-5. Also set res_riu, the smallest index change detectable if the angle can be read to 0.0001°.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Explain why
Explain why a thin silver film on a prism reflects almost all the light at most angles, yet at one particular angle the reflection nearly vanishes.
At most angles the light in the prism can't couple to anything on the far side: it reflects from the metal, which with its large negative permittivity is a good mirror. At the Kretschmann angle, the light's tangential wavevector in the prism, , matches the surface plasmon's on the metal's far side. The evanescent field that leaks through the thin film then drives the plasmon resonantly, and the plasmon carries energy along the surface until the metal's losses absorb it, so little light is reflected. The film's thickness, about 50 nm for silver or gold, is chosen so that the coupling rate matches the plasmon's loss rate, which makes the dip nearly reach zero. Change the medium on the far side and the matching angle moves, which is what a sensor measures.
Practice
Keep practicing
7 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.