Coupling, directivity and isolation, coupled-line couplers from even and odd modes, quadrature and 180° hybrids, and reflectometers

A directional coupler samples a wave traveling one way on a line and ignores the wave traveling the other way. That one trick underlies most RF measurement: a power meter on a coupler reads a transmitter's output without interrupting it, and two couplers facing opposite ways separate the incident and reflected waves, which is the heart of every network analyzer. Hybrids, couplers that split power equally with a fixed 90° or 180° phase difference, build balanced amplifiers, balanced mixers and beamforming networks. All of them come from the same idea: two lines close enough together that a traveling wave on one induces a wave on the other.

  • A single-section coupled-line coupler (a quarter wave long at f0) against frequency: coupled port (solid) and through port (dashed), from the exact even–odd solution.
  • At f0 the coupled port sits exactly at the design coupling; on either side it falls off. A 10 dB coupler stays within 1 dB of 10 dB from 0.69 to 1.31 f0.
  • The readouts give the even- and odd-mode impedances the coupled lines need in a 50 Ω system.

Predict

A reflectometer uses a coupler with 35 dB directivity to measure a load whose true return loss is 30 dB. What might it read?

Name it

Coupler figures of merit

With power P1 into port 1, through port 2, coupled port 3 and isolated port 4:

  • coupling C=10log⁡P1P3 dB;
  • directivity D=10log⁡P3P4 dB, how well it tells forward from backward;
  • isolation I=10log⁡P1P4=C+D dB.

A lossless matched coupler sends the rest of the power to the through port: |S21|2=1−|S31|2.

The coupled-line coupler

Two lines a quarter wave long, close enough to couple, support an even mode (both lines at the same potential, impedance Z0e) and an odd mode (opposite potentials, Z0o<Z0e). Matching at every port and full isolation need

Z0=Z0eZ0o,C=Z0e−Z0oZ0e+Z0o

(C here as a voltage ratio), so Z0e=Z01+C1−C and Z0o=Z01−C1+C. Away from f0 the coupling is Csin⁡θ(1−C2)cos2⁡θ+sin2⁡θ. The coupled wave travels backward, emerging at the end nearer the input. Microstrip's unequal even- and odd-mode speeds spoil the directivity; stripline doesn't have that problem. Tight couplings (3 dB) need interdigitated Lange couplers.

Hybrids

  • Branch-line (90°) hybrid: a square of λ/4 lines, two of Z0/2 and two of Z0. Equal split, outputs 90° apart, the fourth port isolated. Bandwidth about 10 to 20%.
  • Rat-race (180°) hybrid: a ring 112λ around of 2Z0 line. Feeding one port gives in-phase outputs; feeding the other gives outputs 180° apart. The sum (Σ) and difference (Δ) ports make monopulse radar and balanced mixers.

Worked example

Design a 20 dB coupled-line coupler for a 50 Ω system.

Show the solution
  1. Voltage coupling. C=10−20/20=0.1
  2. Even- and odd-mode impedances. Z0e=501.1/0.9=55.3ΩZ0o=500.9/1.1=45.2Ω
  3. Check. 55.3×45.2=50Ω55.3−45.255.3+45.2=0.1
  4. Length and band. The lines are a quarter wave long at the center frequency; at 0.7 f0 the coupling has fallen to 21.0 dB.

Answer Z0e = 55.3 Ω and Z0o = 45.2 Ω, with the lines a quarter wave long at the center frequency.

Worked example

A coupler with 20 dB coupling and 35 dB directivity samples a 10 W transmitter. What reaches the coupled and isolated ports?

Show the solution
  1. Coupled port. 10 W is 40 dBm, so 40−20=20dBm which is 100 mW.
  2. Isolated port. It sits 20 + 35 = 55 dB below the input: 40−55=−15dBm which is 32 µW.
  3. Through port. It carries the remaining 9.9 W, a through loss of 0.04 dB.

Answer 100 mW (20 dBm) reaches the coupled port and 32 µW (−15 dBm) the isolated port.

Worked example

Design a 10 dB coupled-line coupler for 50 Ω, and find its coupling at 70% of the design frequency.

Show the solution
  1. Voltage coupling. C=10−10/20=0.316
  2. Even- and odd-mode impedances. Z0e=501.316/0.684=69.4ΩZ0o=500.684/1.316=36.0Ω
  3. Coupling at 0.7 f0. There the lines are 63° long: 0.316×0.8910.9×0.206+0.794=0.285 or 10.9 dB.
  4. Bandwidth. That's under a decibel weaker across a 30% shift, which is why a quarter-wave coupler covers roughly an octave.

Answer Z0e = 69.4 Ω and Z0o = 36.0 Ω, and at 70% of the design frequency the coupling is 10.9 dB.

Check

A 10 dB coupler samples a 40 dBm signal. What power reaches the coupled port?

Check

A coupler has 20 dB coupling and 20 dB directivity. What's its isolation?

Check

What even-mode impedance does a 10 dB coupled-line coupler need in a 50 Ω system?

Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.

Check

Coupled lines have Z0e = 70 Ω and Z0o = 30 Ω. What coupling do they give, in dB?

Check

A reflectometer with 35 dB directivity measures a load with 25 dB true return loss. What's the lowest return loss it could read?

Check

How long is the ring of a rat-race hybrid at 3.5 GHz on a line with εeff = 1?

Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.

Check

A 10 dB coupled-line coupler in 50 Ω is used where its lines are 45° long.

(a)

What odd-mode impedance does it have?

Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.

(b)

What coupling does it give there?

Check

Coupled lines have even- and odd-mode impedances E and O.

Step 1

For what system impedance are they matched?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why does a directional coupler need high directivity to measure a well-matched load?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.