title: Directional couplers and hybrids
heading: Coupling, directivity and isolation, coupled-line couplers from even and odd modes, quadrature and 180° hybrids, and reflectometers
eyebrow: S6 · Lesson 18 · Directional couplers and hybrids
xp: 50
---

::: hook
A directional coupler samples a wave traveling one way on a line and ignores the wave traveling the other way. That one trick underlies most RF measurement: a power meter on a coupler reads a transmitter's output without interrupting it, and two couplers facing opposite ways separate the incident and reflected waves, which is the heart of every network analyzer. Hybrids, couplers that split power equally with a fixed 90° or 180° phase difference, build balanced amplifiers, balanced mixers and beamforming networks. All of them come from the same idea: two lines close enough together that a traveling wave on one induces a wave on the other.
:::

::: play
- A single-section coupled-line coupler (a quarter wave long at $f_0$) against frequency: coupled port (solid) and through port (dashed), from the exact even–odd solution.
- At $f_0$ the coupled port sits exactly at the design coupling; on either side it falls off. A 10 dB coupler stays within 1 dB of 10 dB from 0.69 to 1.31 $f_0$.
- The readouts give the even- and odd-mode impedances the coupled lines need in a 50 Ω system.
:::
:::

```sim plot
view: graph
x: f = 0.1..1.9
y: S = -40..0 dB
slider: C = 3..30 = 10 dB
plot: 20*log(10^(-C/20)*abs(sin(pi/2*f))/sqrt((1 - 10^(-C/10))*cos(pi/2*f)^2 + sin(pi/2*f)^2) + 1e-9) | samples: 600 | label: coupled port
plot: 20*log(sqrt(1 - 10^(-C/10))/sqrt((1 - 10^(-C/10))*cos(pi/2*f)^2 + sin(pi/2*f)^2)) | samples: 600 | dashed | color: ch2 | label: through port
readout: Z₀ₑ, Ω = 50*sqrt((1 + 10^(-C/20))/(1 - 10^(-C/20)))
readout: Z₀ₒ, Ω = 50*sqrt((1 - 10^(-C/20))/(1 + 10^(-C/20)))
```

::: predict
## A reflectometer uses a coupler with 35 dB directivity to measure a load whose true return loss is 30 dB. What might it read?

- [ ] Exactly 30 dB
- [ ] Between 29.9 and 30.1 dB
- [x] Anywhere between about 26 and 37 dB
- [ ] Something above 35 dB

::: reveal
Directivity of 35 dB means a little of the forward wave, 35 dB below what a perfect reflection would couple, leaks into the reflected-wave port. The load's reflection is only 30 dB down, so the leak is 0.56 times as large as the signal being measured. Depending on their relative phase, the reading falls anywhere from $30 - 20\log(1.56)$ = 26.1 dB to $30 - 20\log(0.44)$ = 37.2 dB. Measuring good matches needs directivity well beyond the return loss.
:::
:::

::: nameit
## Coupler figures of merit

With power $P_1$ into port 1, through port 2, coupled port 3 and isolated port 4:

- **coupling** $C = 10\log\frac{P_1}{P_3}$ dB;
- **directivity** $D = 10\log\frac{P_3}{P_4}$ dB, how well it tells forward from backward;
- **isolation** $I = 10\log\frac{P_1}{P_4} = C + D$ dB.

A lossless matched coupler sends the rest of the power to the through port: $|S_{21}|^2 = 1 - |S_{31}|^2$.

## The coupled-line coupler

Two lines a quarter wave long, close enough to couple, support an **even mode** (both lines at the same potential, impedance $Z_{0e}$) and an **odd mode** (opposite potentials, $Z_{0o} < Z_{0e}$). Matching at every port and full isolation need

$$Z_0 = \sqrt{Z_{0e}Z_{0o}}, \qquad C = \frac{Z_{0e} - Z_{0o}}{Z_{0e} + Z_{0o}}$$

(C here as a voltage ratio), so $Z_{0e} = Z_0\sqrt{\frac{1 + C}{1 - C}}$ and $Z_{0o} = Z_0\sqrt{\frac{1 - C}{1 + C}}$. Away from $f_0$ the coupling is $\frac{C\sin\theta}{\sqrt{(1 - C^2)\cos^2\theta + \sin^2\theta}}$. The coupled wave travels **backward**, emerging at the end nearer the input. Microstrip's unequal even- and odd-mode speeds spoil the directivity; stripline doesn't have that problem. Tight couplings (3 dB) need interdigitated **Lange** couplers.

## Hybrids

- **Branch-line (90°) hybrid**: a square of λ/4 lines, two of $Z_0/\sqrt{2}$ and two of $Z_0$. Equal split, outputs 90° apart, the fourth port isolated. Bandwidth about 10 to 20%.
- **Rat-race (180°) hybrid**: a ring $1\frac{1}{2}\lambda$ around of $\sqrt{2}Z_0$ line. Feeding one port gives in-phase outputs; feeding the other gives outputs 180° apart. The sum (Σ) and difference (Δ) ports make monopulse radar and balanced mixers.
:::

::: example
## Design a 20 dB coupled-line coupler for a 50 Ω system.

::: solution
1. **Voltage coupling.**
   $$\begin{aligned} C &= 10^{-20/20} \\ &= 0.1 \end{aligned}$$
2. **Even- and odd-mode impedances.**
   $$\begin{aligned} Z_{0e} &= 50\sqrt{1.1/0.9} \\ &= 55.3\ \Omega \\ Z_{0o} &= 50\sqrt{0.9/1.1} \\ &= 45.2\ \Omega \end{aligned}$$
3. **Check.**
   $$\begin{aligned} \sqrt{55.3 \times 45.2} &= 50\ \Omega \\ \frac{55.3 - 45.2}{55.3 + 45.2} &= 0.1 \end{aligned}$$
4. **Length and band.** The lines are a quarter wave long at the center frequency; at 0.7 $f_0$ the coupling has fallen to 21.0 dB.

**Answer:** $Z_{0e}$ = 55.3 Ω and $Z_{0o}$ = 45.2 Ω, with the lines a quarter wave long at the center frequency.
:::
:::

::: example
## A coupler with 20 dB coupling and 35 dB directivity samples a 10 W transmitter. What reaches the coupled and isolated ports?

::: solution
1. **Coupled port.** 10 W is 40 dBm, so
   $$40 - 20 = 20\ \text{dBm}$$
   which is 100 mW.
2. **Isolated port.** It sits 20 + 35 = 55 dB below the input:
   $$40 - 55 = -15\ \text{dBm}$$
   which is 32 µW.
3. **Through port.** It carries the remaining 9.9 W, a through loss of 0.04 dB.

**Answer:** 100 mW (20 dBm) reaches the coupled port and 32 µW (−15 dBm) the isolated port.
:::
:::

::: example
## Design a 10 dB coupled-line coupler for 50 Ω, and find its coupling at 70% of the design frequency.

::: solution
1. **Voltage coupling.**
   $$\begin{aligned} C &= 10^{-10/20} \\ &= 0.316 \end{aligned}$$
2. **Even- and odd-mode impedances.**
   $$\begin{aligned} Z_{0e} &= 50\sqrt{1.316/0.684} \\ &= 69.4\ \Omega \\ Z_{0o} &= 50\sqrt{0.684/1.316} \\ &= 36.0\ \Omega \end{aligned}$$
3. **Coupling at 0.7 $f_0$.** There the lines are 63° long:
   $$\begin{aligned} &\frac{0.316 \times 0.891}{\sqrt{0.9 \times 0.206 + 0.794}} \\ &= 0.285 \end{aligned}$$
   or 10.9 dB.
4. **Bandwidth.** That's under a decibel weaker across a 30% shift, which is why a quarter-wave coupler covers roughly an octave.

**Answer:** $Z_{0e}$ = 69.4 Ω and $Z_{0o}$ = 36.0 Ω, and at 70% of the design frequency the coupling is 10.9 dB.
:::
:::

::: check
given: P = 30 | 40 | 47; C = 10 | 20 | 30
answer: P - C
unit: dBm
tolerance: 0.05

## A {C} dB coupler samples a {P} dBm signal. What power reaches the coupled port?

::: right
Right. {P} − {C} = {answer} dBm.
:::

::: misses
- [P + C] Coupling is a loss: subtract.
- [any] Not yet. Subtract the coupling from the input level.
:::
:::

::: check
given: C = 10 | 20 | 30; D = 20 | 30 | 40
answer: C + D
unit: dB
tolerance: 0.05

## A coupler has {C} dB coupling and {D} dB directivity. What's its isolation?

::: right
Right. I = C + D = {answer} dB.
:::

::: misses
- [D - C] Isolation is from input to the isolated port: coupling plus directivity.
- [any] Not yet. $I = C + D$.
:::
:::

::: check
given: C = 6 | 10 | 15 | 20; Z = 50 | 75
answer: Z*sqrt((1 + 10^(-C/20))/(1 - 10^(-C/20)))
unit: Ω
tolerance: 0.5%

## What even-mode impedance does a {C} dB coupled-line coupler need in a {Z} Ω system?

::: right
Right. $Z_0\sqrt{(1 + C)/(1 - C)}$ with C = $10^{-\given{C}/20}$: {answer} Ω.
:::

::: misses
- [Z*sqrt((1 + 10^(-C/10))/(1 - 10^(-C/10)))] C in these formulas is a voltage ratio: divide the dB by 20.
- [Z*sqrt((1 - 10^(-C/20))/(1 + 10^(-C/20)))] That's the odd-mode impedance.
- [any] Not yet. $Z_{0e} = Z_0\sqrt{(1 + C)/(1 - C)}$.
:::
:::

::: check
given: E = 60 | 70 | 90; O = 30 | 40
answer: 20*log((E + O)/(E - O))
unit: dB
tolerance: 0.05

## Coupled lines have $Z_{0e}$ = {E} Ω and $Z_{0o}$ = {O} Ω. What coupling do they give, in dB?

::: right
Right. $C = (Z_{0e} - Z_{0o})/(Z_{0e} + Z_{0o})$, so {answer} dB.
:::

::: misses
- [10*log((E + O)/(E - O))] C is a voltage ratio: use 20 log.
- [any] Not yet. $C = \frac{Z_{0e} - Z_{0o}}{Z_{0e} + Z_{0o}}$.
:::
:::

::: check
given: R = 20 | 25 | 30; D = 35 | 40 | 50
answer: R - 20*log(1 + 10^((R - D)/20))
unit: dB
tolerance: 0.05

## A reflectometer with {D} dB directivity measures a load with {R} dB true return loss. What's the lowest return loss it could read?

::: right
Right. The leak is $10^{(R - D)/20}$ of the signal; in phase they give {answer} dB.
:::

::: misses
- [R - 20*log(1 - 10^((R - D)/20))] That's the highest reading, with the leak out of phase.
- [any] Not yet. Add the leak's amplitude to the reflection's.
:::
:::

::: check
given: f = 2 | 3.5 | 10; e = 1 | 1.9 | 6.8
answer: 1.5*299.792458/(f*sqrt(e))
unit: mm
tolerance: 0.5%

## How long is the ring of a rat-race hybrid at {f} GHz on a line with $\varepsilon_\text{eff}$ = {e}?

::: right
Right. $1\frac{1}{2}\lambda_g$ = {answer} mm.
:::

::: misses
- [299.792458/(f*sqrt(e))] The ring is one and a half wavelengths around.
- [any] Not yet. Circumference = $1.5\lambda_g$.
:::
:::

::: check
kind: parts
given: C = 6 | 10 | 20; t = 45 | 60 | 120

## A {C} dB coupled-line coupler in 50 Ω is used where its lines are {t}° long.

::: part
answer: 50*sqrt((1 - 10^(-C/20))/(1 + 10^(-C/20)))
unit: Ω
tolerance: 0.5%

### What odd-mode impedance does it have?

::: misses
- [50*sqrt((1 + 10^(-C/20))/(1 - 10^(-C/20)))] That's the even mode, the larger one.
- [any] $Z_0\sqrt{(1 - C)/(1 + C)}$.
:::
:::

::: part
answer: -20*log(10^(-C/20)*sin(t*pi/180)/sqrt((1 - 10^(-C/10))*cos(t*pi/180)^2 + sin(t*pi/180)^2))
unit: dB
tolerance: 0.5%

### What coupling does it give there?

::: misses
- [C] That's at the design frequency, where the lines are 90° long.
- [any] $C\sin\theta/\sqrt{(1 - C^2)\cos^2\theta + \sin^2\theta}$.
:::
:::
:::

::: check
kind: derivation
vars: E = 50..200, O = 10..50

## Coupled lines have even- and odd-mode impedances E and O.

::: step
answer: sqrt(E*O)

### For what system impedance are they matched?
:::

::: step
answer: (E - O)/(E + O)

### What voltage coupling do they give at the center frequency?
:::

::: step
answer: -20*log((E - O)/(E + O))

### In decibels?
:::

::: right
Right. Tight coupling needs a large ratio of even to odd impedance, which needs closely spaced lines: hard to etch below about 6 dB, which is why the Lange coupler interdigitates its lines.
:::
:::

::: explain
## Why does a directional coupler need high directivity to measure a well-matched load?

::: model
To measure a load's reflection, the coupler must pass the small reflected wave to its coupled port while rejecting the much larger forward wave. Directivity says how well it rejects the wrong direction: with 35 dB, a trace of the forward wave 35 dB below a full reflection leaks through. If the load reflects only a little, say 30 dB down, that leak is comparable to the reflection itself, and since they add with an unknown phase the reading could be well above or well below the truth. The error only becomes small when the directivity exceeds the return loss being measured by a comfortable margin, which is why network analyzers correct for their couplers' finite directivity by calibration.
:::
:::

::: practice

::: check
given: C = 10 | 20; D = 25 | 45
answer: C + D
unit: dB
tolerance: 0.05

## Isolation: {C} dB coupling, {D} dB directivity?

::: misses
- [any] C + D.
:::
:::

::: check
given: C = 6 | 8 | 10 | 12 | 15 | 20; Z = 50
answer: Z*sqrt((1 - 10^(-C/20))/(1 + 10^(-C/20)))
unit: Ω
tolerance: 0.5%

## Odd-mode impedance for a {C} dB coupler in {Z} Ω?

::: misses
- [any] $Z_0\sqrt{(1 - C)/(1 + C)}$.
:::
:::

::: check
given: R = 20 | 26; D = 32 | 45
answer: R - 20*log(1 - 10^((R - D)/20))
unit: dB
tolerance: 0.05

## Highest reading: true RL {R} dB, directivity {D} dB?

::: misses
- [any] Leak out of phase: $R - 20\log(1 - 10^{(R - D)/20})$.
:::
:::
:::