S6 · Lesson 16 · Coupling to resonators and loaded Q
External and loaded Q, the coupling coefficient, critical coupling, and measuring a resonator's unloaded Q
A resonator on its own is useless: to filter a signal or set an oscillator's frequency it has to be connected to something, and the connection loads it. Energy now leaks out through the feed as well as being lost in the resonator's own walls, so the Q seen from outside, the loaded Q, is always lower than the resonator's own. How strongly to couple is a design choice. Couple too weakly and almost no power gets in; too strongly and the resonance smears out. Exactly the right amount, critical coupling, absorbs all the incident power at resonance, which is also how engineers measure a resonator's true Q on a network analyzer.
- Reflection from a parallel resonator with = 200, coupled to a 50 Ω feed with coupling coefficient g, against frequency in units of .
- At g = 1 (critical coupling) the resonator absorbs everything at : the reflection dips to zero.
- Below 1 (undercoupled) or above (overcoupled) the dip is shallower, with at resonance. The width of the dip is set by the loaded Q, which falls as the coupling rises.
Predict
A resonator with an unloaded Q of 600 is critically coupled to its feed line. What Q does the feed line see?
- At critical coupling the power lost through the feed equals the power lost inside the resonator, so the external Q equals the unloaded Q and the losses add: . At 5 GHz the measured bandwidth would be 16.7 MHz, twice what the resonator's own losses alone would give.
Name it
Loaded and external Q
Every way energy leaves a resonator adds to its loss rate, so the reciprocals of the Qs add:
- , the unloaded Q, counts only the resonator's own losses (conductor, dielectric, radiation).
- , the external Q, counts power leaving through the coupling. For a series resonator fed from , ; for a parallel one, .
- , the loaded Q, sets the measured bandwidth .
The coupling coefficient
(for a parallel resonator , for a series one ).
- g < 1: undercoupled; g = 1: critically coupled, matched at resonance; g > 1: overcoupled.
- At resonance , and the SWR equals g (overcoupled) or 1/g (undercoupled).
- .
Measuring Q
- Reflection (one port): measure from the width of the response and g from the reflection at resonance, then .
- Transmission (two ports, light coupling): , so . Weak coupling, with insertion loss of 20 dB or more, makes nearly .
Practical coupling elements: a series gap capacitor on microstrip, a loop or probe into a cavity, an iris in a waveguide wall, or the spacing between a dielectric puck and a line.
Worked example
A resonator with Q₀ = 600 at 5 GHz is critically coupled. What are Q_e, Q_L and the bandwidth? What if it's coupled with g = 3 instead?
Show the solution
- Critical coupling. = 600 and = 300, so
- Coupling with g = 3. = 200, and for a bandwidth of 33.3 MHz.
- Reflection at resonance. (SWR 3), so a quarter of the power bounces off.
Answer critically coupled, = 600, = 300 and the bandwidth is 16.7 MHz; with g = 3, = 200, = 150 and the bandwidth is 33.3 MHz, with a quarter of the power reflected.
Worked example
A transmission resonator at 2 GHz shows an 8 MHz half-power bandwidth and 6 dB insertion loss at resonance. What's its unloaded Q?
Show the solution
- Loaded Q.
- Transmission at resonance.
- Unloaded Q.
- How heavy the coupling is. The loaded Q is half the unloaded one; weaker coupling (more insertion loss) would make a closer estimate.
Answer the unloaded Q is about 501.
Worked example
A one-port resonator at 2 GHz shows an SWR of 2.5 at resonance, undercoupled, and a half-power bandwidth of 4 MHz. What are , and ?
Show the solution
- Loaded Q.
- Coupling and unloaded Q. Undercoupled, the SWR is 1/g, so g = 0.4 and
- External Q.
- Check.
- Critical coupling. To reach it, the coupling must be strengthened until falls to 700, which would bring the loaded Q down to half of , 350.
Answer = 500, = 700 and = 1750.
Check
A resonator has Q₀ = 1000 and an external Q of 150. What's its loaded Q?
Check
A resonator is coupled with g = 0.6. What's |Γ| at resonance?
Check
A resonator coupled with g = 0.3 shows a loaded Q of 400. What's its unloaded Q?
Check
A transmission resonator at 3.5 GHz has a 2 MHz half-power bandwidth and 25 dB insertion loss at resonance. What's its unloaded Q?
Check
A parallel resonator with R = 1000 Ω at resonance is connected directly to a 50 Ω feed. What's the coupling coefficient?
Check
A resonator with Q₀ = 500 is overcoupled, and the SWR at resonance is 1.5. What loaded Q will the measured bandwidth show?
Check
An undercoupled one-port resonator at 2 GHz shows |Γ| = 0.6 at resonance and a 1 MHz half-power bandwidth.
(a)
What is the coupling coefficient?
(b)
What is the unloaded Q?
Check
A resonator has unloaded Q q and external Q e.
Step 1
What is the loaded Q?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What is the coupling coefficient?
Step 3
What is |Γ| at resonance?
Explain why
Why does critical coupling make the reflection vanish at resonance?
At resonance a resonator's reactances cancel, so from the feed it looks like a pure resistance, the one that represents its internal loss transformed through the coupling. Changing the coupling changes that transformation. When the coupling is such that this resistance equals the feed line's impedance, the resonator is a matched load at resonance and absorbs all the incident power, with nothing reflected. In terms of Q, the power leaving through the feed would then equal the power lost inside, , which is the condition g = 1. Weaker coupling leaves the transformed resistance too far one way and stronger coupling too far the other, and both reflect.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.