S6 · Lesson 30 · Detectors and power measurement
Schottky square-law detectors, their sensitivity and range, power sensors and radiometers
The simplest microwave receiver is a diode: driven by a small RF voltage, its curved current–voltage characteristic produces a DC output proportional to the RF power. That one effect underlies power meters, automatic level control loops, RFID tags, the detectors in network analyzers and radiometers that measure the temperature of the sky. How much DC a diode gives per microwatt, how weak a signal it can see and where it stops reading true power all follow from the diode equation.
- The curve is a total-power radiometer's resolution against integration time τ: , for a system temperature and bandwidth B.
- A 500 K system with 100 MHz of bandwidth resolves 0.05 K in one second: averaging many independent noise samples ( of them) shrinks the scatter as their square root.
- Wider bandwidth helps exactly as much as longer averaging.
Predict
A zero-bias Schottky detector diode has = 3 µA and n = 1.05. Ideally matched, what DC voltage does −40 dBm of RF produce?
Its junction resistance is = 9.05 kΩ and its current sensitivity = 18.4 A/W, so the open-circuit voltage sensitivity is V/W. At 0.1 µW that is 16.7 mV. Real detectors, with series resistance, junction capacitance and imperfect matching, reach a fraction of this, typically tens of millivolts per microwatt at low gigahertz.
Name it
The square-law detector
A diode's current , expanded about its bias for a small RF voltage v, contains a term in whose average is DC. The current sensitivity (DC current per watt of RF absorbed) is
and with the junction resistance , the open-circuit voltage sensitivity is . The output is proportional to power, , whatever the waveform: the square-law region, up to about −20 dBm.
- Above it the diode rectifies the envelope's peaks and the output grows as the RF voltage, not the power (the linear region), so readings of modulated signals depend on their peak-to-average ratio.
- At the bottom the DC output sinks into the video amplifier's noise; the tangential sensitivity, about −50 dBm for a simple detector, marks where a pulse is just visible.
- Zero-bias Schottky diodes (large , so modest ) need no bias current, which removes bias drift and noise.
Power sensors
Thermistor and thermocouple sensors absorb the power and measure the heat, true power at any waveform but slow; diode sensors are fast and sensitive, corrected for their square-law limits. A sensor's calibration factor relates indicated power to incident power, and the source–sensor mismatch uncertainty (lesson 4) remains.
Radiometers
A radiometer measures noise power, and so temperature. A total-power radiometer with system temperature , bandwidth B and integration time τ resolves
but gain drift mimics temperature changes, so Dicke radiometers switch between the antenna and a reference load, at a cost of a factor of 2 in ΔT.
Worked example
The detector above (β_v = 1.67 × 10⁵ V/W) is used from −50 to −20 dBm. What output range does it give?
Show the solution
- At −50 dBm. That's 10 nW:
- At −20 dBm. That's 10 µW, giving 1.67 V in the square-law ideal, though by then the diode is leaving the square-law region and reads low.
- What the span means. Thirty decibels of input span three decades of output voltage, so detector outputs are usually amplified and digitized on a logarithmic scale.
Answer from 1.67 mV at −50 dBm to 1.67 V at −20 dBm in the square-law ideal, with the real diode reading low at the top.
Worked example
A radiometer has = 500 K and 100 MHz of bandwidth. What does it resolve in 1 s, and how long would 0.01 K take? What does a Dicke switch change?
Show the solution
- Resolution in 1 s.
- Time for 0.01 K. so τ = 25 s.
- Dicke switch. A Dicke radiometer looks at the antenna only half the time and subtracts a reference, doubling ΔT to 0.1 K in 1 s, but its output no longer drifts with the amplifier's gain.
Answer 0.05 K in 1 s, and 25 s for 0.01 K; a Dicke switch doubles ΔT to 0.1 K but stops the output drifting with the amplifier's gain.
Worked example
A power sensor has 95% efficiency and |Γ| = 0.1, and the source has |Γ| = 0.2. The meter, set to the right calibration factor, reads 1.000 mW. What was incident, and how uncertain is the source's available power?
Show the solution
- Calibration factor.
- Incident power. 1.000 mW indicated means incident, which the meter reports once the factor is entered.
- Mismatch uncertainty. The source–sensor interaction adds an uncertainty of which is +0.17 to −0.18 dB, about ±4%.
Answer 1.063 mW was incident, and the source's available power is uncertain by +0.17 to −0.18 dB, about ±4%.
Check
A Schottky detector diode has n = 1.05 and = 1 µA ( = 25.85 mV).
(a)
What is its junction resistance?
Write units the way you normally would: 1.5 kΩ, 1500 Ω and 0.0015 MΩ are the same answer.
(b)
What is its current sensitivity?
(c)
What is its ideal voltage sensitivity?
Check
A detector with a voltage sensitivity of 20000 V/W receives −60 dBm in its square-law region.
(a)
What DC voltage does it give?
Write units the way you normally would: 1.5 µV, 1500 nV and 0.0015 mV are the same answer.
(b)
By what factor does the output grow if the input rises 10 dB?
Check
A total-power radiometer has = 500 K and 1 MHz of bandwidth.
(a)
What does it resolve in 10 s?
Write units the way you normally would: 1.5 K and 1500 mK are the same answer.
(b)
How long must it integrate to resolve 0.05 K?
Check
A power sensor with efficiency 0.95 and |Γ| = 0.15 indicates 10 mW before any calibration factor is applied.
(a)
What is its calibration factor?
(b)
What power was incident?
Write units the way you normally would: 1.5 mW, 1500 µW and 0.0015 W are the same answer.
Check
A source with |Γ| = 0.15 drives a power sensor with |Γ| = 0.05.
(a)
What is the upper mismatch uncertainty?
(b)
And the lower, in magnitude?
Check
A diode detector calibrated with a CW tone reads an OFDM signal of the same average power 0 dB at −35 dBm, but several dB high at 0 dBm. Why?
Check
A detector diode has ideality n and current I (saturation plus bias), with = 0.02585 V, and absorbs P watts.
Step 1
What is its junction resistance?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What is its voltage sensitivity?
Step 3
What DC voltage does it give?
Check
Write rectified(x, N=2000): the average of over a cycle (the DC current in units of , for an RF amplitude x times ), by averaging N equally spaced samples, and square_law(x): the small-signal prediction .
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Explain why
Why does a diode detector's output measure power for weak signals of any waveform but not for strong ones?
For small RF voltages the diode's exponential current can be expanded in a power series, and the term that produces DC is the square of the voltage. The average of the voltage squared is proportional to the signal's power, whatever its shape, so a weak signal's detected output is a true power reading. As the RF voltage grows, higher-order terms in the series take over and the diode starts to conduct only on the peaks, behaving like a peak detector whose output follows the voltage. Signals with the same average power but different peaks, such as a tone and OFDM, then give different readings, so accurate measurements keep the detector in its square-law region or correct for the waveform.
Practice
Keep practicing
8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.