S6 · Lesson 30 · Detectors and power measurement

Schottky square-law detectors, their sensitivity and range, power sensors and radiometers

The simplest microwave receiver is a diode: driven by a small RF voltage, its curved current–voltage characteristic produces a DC output proportional to the RF power. That one effect underlies power meters, automatic level control loops, RFID tags, the detectors in network analyzers and radiometers that measure the temperature of the sky. How much DC a diode gives per microwatt, how weak a signal it can see and where it stops reading true power all follow from the diode equation.

  • The curve is a total-power radiometer's resolution against integration time τ: ΔT=Tsys/Bτ, for a system temperature Tsys and bandwidth B.
  • A 500 K system with 100 MHz of bandwidth resolves 0.05 K in one second: averaging many independent noise samples (Bτ of them) shrinks the scatter as their square root.
  • Wider bandwidth helps exactly as much as longer averaging.

Predict

A zero-bias Schottky detector diode has Is = 3 µA and n = 1.05. Ideally matched, what DC voltage does −40 dBm of RF produce?

Name it

The square-law detector

A diode's current Is(eV/nVT−1), expanded about its bias for a small RF voltage v, contains a term in v2 whose average is DC. The current sensitivity (DC current per watt of RF absorbed) is

βi=12nVT≈19 A/W

and with the junction resistance Rj=nVTIs+Ibias, the open-circuit voltage sensitivity is βv=βiRj. The output is proportional to power, Vout=βvP, whatever the waveform: the square-law region, up to about −20 dBm.

  • Above it the diode rectifies the envelope's peaks and the output grows as the RF voltage, not the power (the linear region), so readings of modulated signals depend on their peak-to-average ratio.
  • At the bottom the DC output sinks into the video amplifier's noise; the tangential sensitivity, about −50 dBm for a simple detector, marks where a pulse is just visible.
  • Zero-bias Schottky diodes (large Is, so modest Rj) need no bias current, which removes bias drift and noise.

Power sensors

Thermistor and thermocouple sensors absorb the power and measure the heat, true power at any waveform but slow; diode sensors are fast and sensitive, corrected for their square-law limits. A sensor's calibration factor Kb=η(1−|Γ|2) relates indicated power to incident power, and the source–sensor mismatch uncertainty (lesson 4) remains.

Radiometers

A radiometer measures noise power, and so temperature. A total-power radiometer with system temperature Tsys, bandwidth B and integration time τ resolves

ΔT=TsysBτ

but gain drift mimics temperature changes, so Dicke radiometers switch between the antenna and a reference load, at a cost of a factor of 2 in ΔT.

Worked example

The detector above (β_v = 1.67 × 10⁵ V/W) is used from −50 to −20 dBm. What output range does it give?

Show the solution
  1. At −50 dBm. That's 10 nW: V=1.67×105×10−8=1.67mV
  2. At −20 dBm. That's 10 µW, giving 1.67 V in the square-law ideal, though by then the diode is leaving the square-law region and reads low.
  3. What the span means. Thirty decibels of input span three decades of output voltage, so detector outputs are usually amplified and digitized on a logarithmic scale.

Answer from 1.67 mV at −50 dBm to 1.67 V at −20 dBm in the square-law ideal, with the real diode reading low at the top.

Worked example

A radiometer has Tsys = 500 K and 100 MHz of bandwidth. What does it resolve in 1 s, and how long would 0.01 K take? What does a Dicke switch change?

Show the solution
  1. Resolution in 1 s. ΔT=500108×1=0.05K
  2. Time for 0.01 K. Bτ=(500/0.01)2=2.5×109 so τ = 25 s.
  3. Dicke switch. A Dicke radiometer looks at the antenna only half the time and subtracts a reference, doubling ΔT to 0.1 K in 1 s, but its output no longer drifts with the amplifier's gain.

Answer 0.05 K in 1 s, and 25 s for 0.01 K; a Dicke switch doubles ΔT to 0.1 K but stops the output drifting with the amplifier's gain.

Worked example

A power sensor has 95% efficiency and |Γ| = 0.1, and the source has |Γ| = 0.2. The meter, set to the right calibration factor, reads 1.000 mW. What was incident, and how uncertain is the source's available power?

Show the solution
  1. Calibration factor. Kb=0.95×0.99=0.9405
  2. Incident power. 1.000 mW indicated means 1.000/0.9405=1.063mW incident, which the meter reports once the factor is entered.
  3. Mismatch uncertainty. The source–sensor interaction adds an uncertainty of 20log10⁡(1±0.2×0.1) which is +0.17 to −0.18 dB, about ±4%.

Answer 1.063 mW was incident, and the source's available power is uncertain by +0.17 to −0.18 dB, about ±4%.

Check

A Schottky detector diode has n = 1.05 and Is+Ibias = 1 µA (VT = 25.85 mV).

(a)

What is its junction resistance?

Write units the way you normally would: 1.5 kΩ, 1500 Ω and 0.0015 MΩ are the same answer.

(b)

What is its current sensitivity?

(c)

What is its ideal voltage sensitivity?

Check

A detector with a voltage sensitivity of 20000 V/W receives −60 dBm in its square-law region.

(a)

What DC voltage does it give?

Write units the way you normally would: 1.5 µV, 1500 nV and 0.0015 mV are the same answer.

(b)

By what factor does the output grow if the input rises 10 dB?

Check

A total-power radiometer has Tsys = 500 K and 1 MHz of bandwidth.

(a)

What does it resolve in 10 s?

Write units the way you normally would: 1.5 K and 1500 mK are the same answer.

(b)

How long must it integrate to resolve 0.05 K?

Check

A power sensor with efficiency 0.95 and |Γ| = 0.15 indicates 10 mW before any calibration factor is applied.

(a)

What is its calibration factor?

(b)

What power was incident?

Write units the way you normally would: 1.5 mW, 1500 µW and 0.0015 W are the same answer.

Check

A source with |Γ| = 0.15 drives a power sensor with |Γ| = 0.05.

(a)

What is the upper mismatch uncertainty?

(b)

And the lower, in magnitude?

Check

A diode detector calibrated with a CW tone reads an OFDM signal of the same average power 0 dB at −35 dBm, but several dB high at 0 dBm. Why?

Check

A detector diode has ideality n and current I (saturation plus bias), with VT = 0.02585 V, and absorbs P watts.

Step 1

What is its junction resistance?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Check

Write rectified(x, N=2000): the average of excos⁡θ−1 over a cycle (the DC current in units of Is, for an RF amplitude x times nVT), by averaging N equally spaced samples, and square_law(x): the small-signal prediction x2/4.

Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.

Explain why

Why does a diode detector's output measure power for weak signals of any waveform but not for strong ones?