title: Detectors and power measurement
heading: Schottky square-law detectors, their sensitivity and range, power sensors and radiometers
eyebrow: S6 · Lesson 30 · Detectors and power measurement
xp: 50
---

::: hook
The simplest microwave receiver is a diode: driven by a small RF voltage, its curved current–voltage characteristic produces a DC output proportional to the RF power. That one effect underlies power meters, automatic level control loops, RFID tags, the detectors in network analyzers and radiometers that measure the temperature of the sky. How much DC a diode gives per microwatt, how weak a signal it can see and where it stops reading true power all follow from the diode equation.
:::

::: play
- The curve is a total-power radiometer's resolution against integration time τ: $\Delta T = T_\text{sys}/\sqrt{B\tau}$, for a system temperature $T_\text{sys}$ and bandwidth B.
- A 500 K system with 100 MHz of bandwidth resolves 0.05 K in one second: averaging many independent noise samples ($B\tau$ of them) shrinks the scatter as their square root.
- Wider bandwidth helps exactly as much as longer averaging.
:::

```sim plot
view: graph
x: t = 0.001..100 s log
y: T = 0.001..10 K log
slider: S = 50..1000 = 500 K
slider: B = 1..1000 = 100 MHz log
plot: S/sqrt(B*1e6*t) | label: ΔT
```

::: predict
## A zero-bias Schottky detector diode has $I_s$ = 3 µA and n = 1.05. Ideally matched, what DC voltage does −40 dBm of RF produce?

- [ ] About 17 nV
- [ ] About 17 µV
- [x] About 17 mV
- [ ] About 1.7 V

::: reveal
Its junction resistance is $nV_T/I_s$ = 9.05 kΩ and its current sensitivity $1/(2nV_T)$ = 18.4 A/W, so the open-circuit voltage sensitivity is $18.4 \times 9050 = 1.67 \times 10^5$ V/W. At 0.1 µW that is 16.7 mV. Real detectors, with series resistance, junction capacitance and imperfect matching, reach a fraction of this, typically tens of millivolts per microwatt at low gigahertz.
:::
:::

::: nameit
## The square-law detector

A diode's current $I_s(e^{V/nV_T} - 1)$, expanded about its bias for a small RF voltage v, contains a term in $v^2$ whose average is DC. The **current sensitivity** (DC current per watt of RF absorbed) is
$$\beta_i = \frac{1}{2nV_T} \approx 19\text{ A/W}$$
and with the junction resistance $R_j = \frac{nV_T}{I_s + I_\text{bias}}$, the open-circuit **voltage sensitivity** is $\beta_v = \beta_iR_j$. The output is proportional to power, $V_\text{out} = \beta_vP$, whatever the waveform: the **square-law region**, up to about −20 dBm.

- Above it the diode rectifies the envelope's peaks and the output grows as the RF voltage, not the power (the **linear region**), so readings of modulated signals depend on their peak-to-average ratio.
- At the bottom the DC output sinks into the video amplifier's noise; the **tangential sensitivity**, about −50 dBm for a simple detector, marks where a pulse is just visible.
- Zero-bias Schottky diodes (large $I_s$, so modest $R_j$) need no bias current, which removes bias drift and noise.

## Power sensors

**Thermistor** and **thermocouple** sensors absorb the power and measure the heat, true power at any waveform but slow; **diode** sensors are fast and sensitive, corrected for their square-law limits. A sensor's **calibration factor** $K_b = \eta(1 - |\Gamma|^2)$ relates indicated power to incident power, and the source–sensor mismatch uncertainty (lesson 4) remains.

## Radiometers

A **radiometer** measures noise power, and so temperature. A total-power radiometer with system temperature $T_\text{sys}$, bandwidth B and integration time τ resolves
$$\Delta T = \frac{T_\text{sys}}{\sqrt{B\tau}}$$
but gain drift mimics temperature changes, so **Dicke radiometers** switch between the antenna and a reference load, at a cost of a factor of 2 in ΔT.
:::

::: example
## The detector above (β_v = 1.67 × 10⁵ V/W) is used from −50 to −20 dBm. What output range does it give?

::: solution
1. **At −50 dBm.** That's 10 nW:
   $$\begin{aligned} V &= 1.67 \times 10^5 \times 10^{-8} \\ &= 1.67\ \text{mV} \end{aligned}$$
2. **At −20 dBm.** That's 10 µW, giving 1.67 V in the square-law ideal, though by then the diode is leaving the square-law region and reads low.
3. **What the span means.** Thirty decibels of input span three decades of output voltage, so detector outputs are usually amplified and digitized on a logarithmic scale.

**Answer:** from 1.67 mV at −50 dBm to 1.67 V at −20 dBm in the square-law ideal, with the real diode reading low at the top.
:::
:::

::: example
## A radiometer has $T_\text{sys}$ = 500 K and 100 MHz of bandwidth. What does it resolve in 1 s, and how long would 0.01 K take? What does a Dicke switch change?

::: solution
1. **Resolution in 1 s.**
   $$\begin{aligned} \Delta T &= \frac{500}{\sqrt{10^8 \times 1}} \\ &= 0.05\ \text{K} \end{aligned}$$
2. **Time for 0.01 K.**
   $$\begin{aligned} B\tau &= (500/0.01)^2 \\ &= 2.5 \times 10^9 \end{aligned}$$
   so τ = 25 s.
3. **Dicke switch.** A Dicke radiometer looks at the antenna only half the time and subtracts a reference, doubling ΔT to 0.1 K in 1 s, but its output no longer drifts with the amplifier's gain.

**Answer:** 0.05 K in 1 s, and 25 s for 0.01 K; a Dicke switch doubles ΔT to 0.1 K but stops the output drifting with the amplifier's gain.
:::
:::

::: example
## A power sensor has 95% efficiency and |Γ| = 0.1, and the source has |Γ| = 0.2. The meter, set to the right calibration factor, reads 1.000 mW. What was incident, and how uncertain is the source's available power?

::: solution
1. **Calibration factor.**
   $$\begin{aligned} K_b &= 0.95 \times 0.99 \\ &= 0.9405 \end{aligned}$$
2. **Incident power.** 1.000 mW indicated means
   $$1.000/0.9405 = 1.063\ \text{mW}$$
   incident, which the meter reports once the factor is entered.
3. **Mismatch uncertainty.** The source–sensor interaction adds an uncertainty of
   $$20\log_{10}(1 \pm 0.2 \times 0.1)$$
   which is +0.17 to −0.18 dB, about ±4%.

**Answer:** 1.063 mW was incident, and the source's available power is uncertain by +0.17 to −0.18 dB, about ±4%.
:::
:::

::: check
kind: parts
given: n = 1 | 1.05 | 1.2; I = 1 | 3 | 10

## A Schottky detector diode has n = {n} and $I_s + I_\text{bias}$ = {I} µA ($V_T$ = 25.85 mV).

::: part
answer: n*0.02585/(I*1e-6)/1000
unit: kΩ
tolerance: 0.5%

### What is its junction resistance?

::: misses
- [any] $nV_T/(I_s + I_\text{bias})$.
:::
:::

::: part
answer: 1/(2*n*0.02585)
unit: A/W
tolerance: 0.5%

### What is its current sensitivity?

::: misses
- [1/(n*0.02585)] The square-law term carries a factor of one half.
- [any] $1/(2nV_T)$.
:::
:::

::: part
answer: 1/(2*n*0.02585)*n*0.02585/(I*1e-6)
unit: V/W
tolerance: 0.5%

### What is its ideal voltage sensitivity?

::: misses
- [any] $\beta_iR_j$.
:::
:::
:::

::: check
kind: parts
given: b = 2000 | 20000 | 166667; P = -60 | -45 | -30

## A detector with a voltage sensitivity of {b} V/W receives {P} dBm in its square-law region.

::: part
answer: b*10^(P/10)*1e-3*1e6
unit: µV
tolerance: 0.5%

### What DC voltage does it give?

::: misses
- [any] $\beta_vP$ with P in watts.
:::
:::

::: part
answer: 10
tolerance: 0

### By what factor does the output grow if the input rises 10 dB?

::: misses
- [3.162] That's the linear region; in the square-law region the output follows power.
- [any] Output is proportional to power.
:::
:::
:::

::: check
kind: parts
given: T = 100 | 500 | 2000; B = 1 | 20 | 400; t = 0.1 | 1 | 10; D = 0.01 | 0.05

## A total-power radiometer has $T_\text{sys}$ = {T} K and {B} MHz of bandwidth.

::: part
answer: T/sqrt(B*1e6*t)
unit: K
tolerance: 0.5%

### What does it resolve in {t} s?

::: misses
- [any] $T_\text{sys}/\sqrt{B\tau}$.
:::
:::

::: part
answer: (T/D)^2/(B*1e6)
unit: s
tolerance: 0.5%

### How long must it integrate to resolve {D} K?

::: misses
- [any] $\tau = (T_\text{sys}/\Delta T)^2/B$.
:::
:::
:::

::: check
kind: parts
given: e = 0.9 | 0.95 | 0.99; g = 0.15 | 0.2 | 0.3; P = 0.5 | 1 | 10

## A power sensor with efficiency {e} and |Γ| = {g} indicates {P} mW before any calibration factor is applied.

::: part
answer: e*(1 - g^2)
tolerance: 0.5%

### What is its calibration factor?

::: misses
- [e] The sensor also reflects part of the incident power.
- [any] $\eta(1 - |\Gamma|^2)$.
:::
:::

::: part
answer: P/(e*(1 - g^2))
unit: mW
tolerance: 0.5%

### What power was incident?

::: misses
- [P*e*(1 - g^2)] Divide by the calibration factor.
- [any] $P_\text{ind}/K_b$.
:::
:::
:::

::: check
kind: parts
given: s = 0.05 | 0.15 | 0.3; l = 0.05 | 0.1 | 0.2

## A source with |Γ| = {s} drives a power sensor with |Γ| = {l}.

::: part
answer: 20*log(1 + s*l)
unit: dB
tolerance: 0.5%

### What is the upper mismatch uncertainty?

::: misses
- [any] $20\log_{10}(1 + |\Gamma_S||\Gamma_L|)$.
:::
:::

::: part
answer: -20*log(1 - s*l)
unit: dB
tolerance: 0.5%

### And the lower, in magnitude?

::: misses
- [any] $-20\log_{10}(1 - |\Gamma_S||\Gamma_L|)$.
:::
:::
:::

::: check
kind: choice

## A diode detector calibrated with a CW tone reads an OFDM signal of the same average power 0 dB at −35 dBm, but several dB high at 0 dBm. Why?

- [ ] OFDM has more power than the tone
- [x] At −35 dBm the diode is in its square-law region, where the output follows average power regardless of waveform; at 0 dBm it is near the linear region, where it responds to the envelope's voltage, and OFDM's high peaks push the reading up
- [ ] The diode heats up at 0 dBm
- [ ] OFDM's bandwidth exceeds the detector's

::: misses
- [1] The average powers are equal by construction.
- [3] Self-heating is small; the effect is the detector law.
- [4] The detector's video bandwidth affects how it follows the envelope, but the error comes from leaving the square-law region.
:::
:::

::: check
kind: derivation
vars: n = 1..1.5, I = 1e-7..1e-4, P = 1e-9..1e-5

## A detector diode has ideality n and current I (saturation plus bias), with $V_T$ = 0.02585 V, and absorbs P watts.

::: step
answer: n*0.02585/I

### What is its junction resistance?
:::

::: step
answer: 1/(2*n*0.02585)*n*0.02585/I

### What is its voltage sensitivity?
:::

::: step
answer: 1/(2*n*0.02585)*n*0.02585/I*P

### What DC voltage does it give?
:::

::: right
Right. The ideality cancels in $\beta_v = 1/(2I)$: sensitivity is set by the current through the junction, which is why zero-bias diodes are chosen for their saturation current.
:::
:::

::: check
kind: python

## Write `rectified(x, N=2000)`: the average of $e^{x\cos\theta} - 1$ over a cycle (the DC current in units of $I_s$, for an RF amplitude x times $nV_T$), by averaging N equally spaced samples, and `square_law(x)`: the small-signal prediction $x^2/4$.

```python starter
def rectified(x, N=2000):
    return 0.0

def square_law(x):
    return 0.0
```

```python solution
import math

def rectified(x, N=2000):
    return sum(math.exp(x * math.cos(2 * math.pi * (k + 0.5) / N)) - 1 for k in range(N)) / N

def square_law(x):
    return x * x / 4
```

```python tests
assert abs(rectified(0.1) / square_law(0.1) - 1) < 0.001, "Small signals follow the square law."
assert 1.05 < rectified(1) / square_law(1) < 1.08, "At x = 1 the next term adds about 6%."
assert rectified(3) / square_law(3) > 1.5, "By x = 3 the detector has left the square-law region."
```

::: right
Right. The exact average is $I_0(x) - 1$, a Bessel function; its series $x^2/4 + x^4/64 + \dots$ shows where the square law starts to fail.
:::
:::

::: explain
## Why does a diode detector's output measure power for weak signals of any waveform but not for strong ones?

::: model
For small RF voltages the diode's exponential current can be expanded in a power series, and the term that produces DC is the square of the voltage. The average of the voltage squared is proportional to the signal's power, whatever its shape, so a weak signal's detected output is a true power reading. As the RF voltage grows, higher-order terms in the series take over and the diode starts to conduct only on the peaks, behaving like a peak detector whose output follows the voltage. Signals with the same average power but different peaks, such as a tone and OFDM, then give different readings, so accurate measurements keep the detector in its square-law region or correct for the waveform.
:::
:::

::: practice
::: check
given: n = 1.05 | 1.1; I = 2 | 5
answer: n*0.02585/(I*1e-6)/1000
unit: kΩ
tolerance: 0.5%

## Junction resistance for n = {n}, {I} µA?

::: misses
- [any] $nV_T/I$.
:::
:::

::: check
given: T = 300 | 800; B = 10 | 500; t = 0.5 | 4
answer: T/sqrt(B*1e6*t)
unit: K
tolerance: 0.5%

## Radiometer ΔT: {T} K, {B} MHz, {t} s?

::: misses
- [any] $T_\text{sys}/\sqrt{B\tau}$.
:::
:::

::: check
given: e = 0.92 | 0.98; g = 0.08 | 0.15
answer: e*(1 - g^2)
tolerance: 0.5%

## Calibration factor for efficiency {e}, |Γ| = {g}?

::: misses
- [any] $\eta(1 - |\Gamma|^2)$.
:::
:::
:::