S6 · Lesson 41 · Injection locking and pulling
How a weak signal captures an oscillator's frequency, and how far away it still can
Hang two pendulum clocks on the same wall and they end up ticking in step: each nudges the other through the wall. Oscillators do the same. A weak signal injected into a free-running oscillator, if it's close enough in frequency, takes over: the oscillator runs at the injected frequency, with that signal's phase noise, while still delivering its own full power. That's injection locking, used for frequency dividers, low-noise sources and phased-array synchronization. When the injected signal is a little too far away, the oscillator is pulled: it wobbles toward the intruder without locking, which is why a transmitter's own output can disturb its oscillator. Adler's equation, from 1946, predicts both.
- The lock range of an oscillator (half-width, in MHz) against the injected signal's strength relative to the oscillator, by Adler's equation , for a 10 GHz oscillator.
- A higher-Q resonator resists being pushed: the lock range shrinks in proportion to .
Predict
A 10 GHz oscillator with a loaded Q of 20 receives a signal 20 dB weaker than its own. How far from 10 GHz can that signal be and still lock it?
20 dB below is an amplitude ratio of 0.1, so = 25 MHz on either side. Within ±25 MHz the oscillator follows the injected frequency exactly; outside, it beats against it.
Name it
Adler's equation
An LC oscillator with resonant frequency and loaded quality factor , injected with a signal at of amplitude (relative to its own ), has a phase difference φ between its output and the injection that obeys
with , for weak injection.
Locked
If , the phase settles where : the oscillator runs exactly at , with a static phase offset that reaches ±90° at the edges of the lock range. Close to the injection frequency, the locked oscillator's phase noise follows the injected signal's; far from it, the oscillator's own noise returns. So a clean, weak reference can clean up a powerful oscillator: an injection-locked amplifier.
Pulled
If , the phase slips continuously, but unevenly: it lingers near the point where the injection almost holds it. The beat frequency between oscillator and injection is
lower than the plain difference, which is the oscillator being pulled toward the intruder. In a transmitter, the power amplifier's output leaking back to the VCO at a nearby frequency can pull it, distorting the modulation.
Uses
Injection locking divides frequencies (an oscillator near locked by a signal at through a nonlinearity), synchronizes the elements of phased arrays, and makes low-power quadrature sources. Its weakness is the narrow lock range, which tracks process and temperature through .
Worked example
A 10 GHz oscillator with = 20 is injected 20 dB below its own level. Find the lock range, and the phase offset when the injection is 10 MHz from its free-running frequency.
Show the solution
- Lock range.
- Phase offset. At 10 MHz offset, so φ = 23.6°.
- What the oscillator does. It runs exactly 10 MHz from its natural frequency, at a constant phase from the injection.
Answer a 25 MHz lock range, and a 23.6° phase offset at 10 MHz.
Worked example
The same injection is moved 30 MHz away. What beat frequency appears, and why isn't it 30 MHz?
Show the solution
- Beat frequency.
- Why it's lower. The injection is too far away to lock, but it pulls the oscillator toward itself for part of each beat cycle, slowing the phase slip there, so the average frequency difference is smaller than 30 MHz.
- Far outside the lock range. The beat approaches the plain difference.
Answer a 16.6 MHz beat, below 30 MHz because the injection pulls the oscillator toward itself for part of each beat cycle.
Worked example
An injection-locked frequency divider needs a ±200 MHz lock range at 20 GHz. If the injected signal reaches the tank at a third of the oscillation amplitude, what is the highest Q the tank can have?
Show the solution
- Lock range.
- Solve for Q.
- The trade. Low-Q tanks give wide lock ranges but more phase noise when unlocked; a divider that must lock reliably across process corners trades the other way.
Answer a Q of at most 16.7.
Check
An oscillator at 5 GHz with loaded Q 10 receives an injection −10 dB relative to its own amplitude. What is its lock range half-width?
Write units the way you normally would: 1.5 MHz, 1500 kHz and 0.0015 GHz are the same answer.
Check
A locked oscillator has a lock range of ±12 MHz, and the injection is 5 MHz from its free-running frequency. What is the static phase offset?
Check
An injection 50 MHz away pulls an oscillator whose lock range is ±20 MHz. What beat frequency results?
Write units the way you normally would: 1.5 MHz, 1500 kHz and 0.0015 GHz are the same answer.
Check
A divider at 20 GHz needs a ±100 MHz lock range with injection at 0.33 of the oscillation amplitude. What is the highest tank Q that allows it?
Check
Within its lock range, an injection-locked oscillator's close-in phase noise follows which source?
Check
Find where Adler's equation settles inside the lock range.
Step 1
Setting in , what is ?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What is the equilibrium phase φ?
Check
Integrate Adler's equation, , in normalized units with = L = 1 and = d = 0.5, from φ = 0 for = 0 to 400 with RK4 and step 0.001. Set locked (True if the final rate is below 1e-6 in size), and beat, the average rate over the second half.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Explain why
A transmitter's VCO runs at exactly the carrier frequency, and its power amplifier's output, 40 dB stronger than the VCO's own level, couples weakly back into it. Explain why the transmitted spectrum degrades, and why many transmitters run the VCO at twice the carrier and divide by two.
The PA's output, modulated and much stronger than the VCO, leaks back into the VCO's tank; because it sits at nearly the same frequency, Adler's equation applies and the leaked signal pulls the VCO, shifting its phase in step with the modulation. The VCO's output is then no longer a clean carrier, so the transmitted signal is distorted and its spectrum widens, a problem called VCO pulling. Running the VCO at twice the carrier and dividing moves its frequency far from the PA's: the leaked signal is then outside any plausible lock range, , so it barely disturbs the oscillator. Isolation, buffers and frequency planning all aim to keep strong signals out of an oscillator's lock range.
Practice
Keep practicing
7 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.