S636 of 55
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

S6 · Lesson 36 · Load lines and load-pull

The load that gets the most power out of a transistor, and how to find it when the models run out

A small-signal amplifier is matched for gain: lesson 33 chose the conjugate of the transistor's output impedance. A power amplifier is different. Its output is limited by how far the voltage can swing before the transistor saturates and how much current it can carry, so the best load is the one that reaches both limits at once, and it's usually nowhere near the conjugate match. Steve Cripps's load-line argument gives that load in one line. Real devices add parasitics, nonlinear capacitances and thermal effects, so engineers find the best load experimentally by load-pull: presenting the transistor with many load impedances and mapping the output power and efficiency on a Smith chart.

  • The output power of a transistor against its load resistance, as a fraction of the maximum, following Cripps's load-line rule: below Ropt the current limit caps the power at (R/Ropt)Pmax; above it the voltage limit caps it at (Ropt/R)Pmax.
  • The dashed lines mark the 1 dB contour's resistances, 0.79 and 1.26 times Ropt: a power amplifier's load can be off by about 25% in either direction for 1 dB of power.

Predict

A transistor on a 28 V supply has a 3 V knee and must deliver 10 W in class B. What load resistance should its drain see?

Name it

The load line

With the drain swinging between the knee voltage Vk and roughly 2VDD−Vk, the peak voltage swing is VDD−Vk. If the load is R, the output power is limited by whichever runs out first:

  • Voltage limit: P=(VDD−Vk)2/(2R), for large R.
  • Current limit: with peak current Imax/2 in the load (class B), P=Imax2R/8, for small R.

They meet at

Ropt=(VDD−Vk)22Pmax

the Cripps load. Away from it, power falls in proportion to R/Ropt below and Ropt/R above, so contours of constant power on a Smith chart are not circles of conjugate mismatch: a 1 dB drop allows a factor of 1.26 either way.

Efficiency

An ideal class B amplifier at full swing has drain efficiency π/4 = 78.5%; the knee reduces it by (VDD−Vk)/VDD. The load for best efficiency differs slightly from the load for best power, so designers trade between their contours.

Load-pull

At microwave frequencies the device's output capacitance, package parasitics and harmonics make the right load complex and hard to predict. A load-pull system uses mechanical or electronic tuners (or active signal injection) to present a sweep of load impedances while measuring output power, gain and efficiency, and draws contours on the Smith chart. The designer then synthesizes a matching network from 50 Ω to the chosen point, as in lessons 8 and 9.

Worked example

Find the Cripps load and the ideal class B efficiency for a 28 V transistor with a 3 V knee delivering 10 W. What's the reflection coefficient of that load in a 50 Ω system?

Show the solution
  1. Cripps load. Ropt=(28−3)22×10=31.25Ω
  2. Efficiency. η=(π/4)(25/28)=70.1%
  3. Reflection coefficient. Against 50 Ω, Γ=31.25−5031.25+50=−0.231 a modest match, but it must be transformed accurately because power falls fast once both limits bite.

Answer Ropt = 31.25 Ω, with an ideal class B efficiency of 70.1% and Γ = −0.231 in a 50 Ω system.

Worked example

The same transistor sees 50 Ω directly. What power does it deliver, and how many dB below maximum is that?

Show the solution
  1. Which limit applies. 50 Ω is above Ropt, so the voltage limit applies.
  2. Power. P=2522×50=6.25W or equivalently (31.25/50)×10 W.
  3. In decibels. 10log10⁡(0.625)=−2.0dB
  4. Matching. A matching network costs a few tenths of a decibel and recovers the rest.

Answer 6.25 W, 2.0 dB below the maximum.

Worked example

What range of load resistances keeps the output within 1 dB of maximum for Ropt = 31.25 Ω?

Show the solution
  1. 1 dB as a ratio. 1 dB is a factor of 0.794.
  2. Below Ropt. The output stays within 1 dB while R/Ropt≥0.794 so R ≥ 24.8 Ω.
  3. Above Ropt. It stays within 1 dB while Ropt/R≥0.794 so R ≤ 39.3 Ω.
  4. The window. It runs from 24.8 to 39.3 Ω, not symmetric in ohms but symmetric in ratio. Real load-pull contours tilt and stretch with reactance, which is why they're measured.

Answer from 24.8 Ω to 39.3 Ω.

Check

A transistor on 28 V with a 1 V knee is to deliver 50 W. What is its Cripps load?

Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.

Check

A power amplifier's optimum load is 15 Ω. By how many dB does its output fall (a negative number) with a 20 Ω load, by the load-line rule?

Check

What is the ideal class B drain efficiency at full swing for a 28 V supply with a 1 V knee, in percent?

Check

A PA's optimum load is 12.5 Ω in a 50 Ω system.

(a)

What is its reflection coefficient?

(b)

What impedance transformation ratio must its matching network provide?

Check

A PA's optimum load is 31.25 Ω. What is the lowest load resistance that keeps the output within 0.5 dB of maximum?

Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.

Check

Why is a power amplifier's output usually not conjugately matched to the transistor's output impedance?

Check

Map a load-pull contour. A transistor on V = 12 V with knee k = 2 V and peak current Im = 3 A drives a resistive load in class B. Write pout(R) as the smaller of the voltage-limited (V−k)2/(2R) and current-limited Im2R/8. Set R_opt (where they're equal), P_max, and window, the (low, high) pair of resistances where pout is exactly 1 dB below P_max.

Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.

Explain why

A designer conjugately matches a 10 W GaN transistor's output using its small-signal S-parameters, and gets much less power than the datasheet promises. Explain what went wrong and how load-pull data would fix it.

Practice

Keep practicing

8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.