title: Noise in microwave systems
heading: Noise temperature and noise figure, cascades and the Friis formula, lossy lines, Y-factor measurement and receiver sensitivity
eyebrow: S6 · Lesson 29 · Noise in microwave systems
xp: 50
---

::: hook
A receiver's job is to pull a weak signal out of noise, and every component it contains adds a little more. Physics II and the thermal-physics course introduced Johnson noise and the noise temperature; here they become the working tools of receiver design. The key result is Friis's formula for a cascade: the first stage's noise counts in full, but each later stage's noise is divided by the gain in front of it. That's why a satellite dish puts a low-noise amplifier right at the feed, why a meter of lossy cable before that amplifier costs as much as its own noise figure, and why the order of the blocks in a receiver matters so much.
:::

::: play
- The noise figure of a three-stage receiver, an LNA, a passive mixer (7 dB loss, 7 dB noise figure) and an IF amplifier (NF 3 dB), against the LNA's gain, with an optional lossy cable in front.
- With enough LNA gain the total approaches the LNA's own noise figure plus the cable loss; with too little, the mixer's noise shows through.
- Every decibel of cable loss before the LNA adds a full decibel to the system noise figure, whatever the LNA's gain.
:::
:::

```sim plot
view: graph
x: G = 0..35 dB
y: NF = 0..10 dB
slider: F = 0.3..4 = 1 dB
slider: L = 0..3 = 0 dB
plot: L + 10*log(10^(F/10) + (10^0.7 - 1)/10^(G/10) + (10^0.3 - 1)/(10^(G/10)*10^(-0.7))) | samples: 400 | label: system noise figure
plot: L + F | dashed | color: ch3 | label: cable loss + LNA noise figure
readout: system noise temperature at 20 dB LNA gain, K = 290*(10^(L/10)*(10^(F/10) + (10^0.7 - 1)/100 + (10^0.3 - 1)/(100*10^(-0.7))) - 1)
```

::: predict
## A receiver has an LNA (NF 1 dB, gain 20 dB) followed by a mixer (NF 7 dB, loss 7 dB). What happens to the system noise figure if the two are swapped, mixer first?

- [ ] Nothing: the same parts give the same noise
- [ ] It improves slightly
- [x] It rises from about 1.3 dB to about 8 dB
- [ ] It rises to exactly 8 dB, the sum

::: reveal
With the LNA first, the mixer's noise is divided by the LNA's gain of 100, and the total is 1.30 dB (with a 3 dB IF amplifier after). With the mixer first, its 7 dB counts in full and its loss then multiplies the LNA's contribution: the total is 8.03 dB. The first stage needs both low noise and enough gain to hide everything behind it.
:::
:::

::: nameit
## Noise temperature and noise figure

- A resistor at temperature T delivers available noise power **kTB** to a matched load: −174 dBm in 1 Hz at $T_0$ = 290 K.
- A noisy two-port's **equivalent noise temperature** $T_e$ is the extra input temperature that would account for its output noise.
- **Noise figure** $F = \frac{(S/N)_\text{in}}{(S/N)_\text{out}}$ with a 290 K source, so $F = 1 + T_e/T_0$, and NF = 10 log F.

## Cascades (Friis)

$$T_e = T_{e1} + \frac{T_{e2}}{G_1} + \frac{T_{e3}}{G_1G_2} + \cdots, \qquad F = F_1 + \frac{F_2 - 1}{G_1} + \frac{F_3 - 1}{G_1G_2} + \cdots$$

(gains as power ratios, available gains strictly).

## Lossy components

A matched attenuator of loss L (as a power ratio) at physical temperature T has $G = 1/L$ and $T_e = (L - 1)T$. At T = 290 K its noise figure equals its loss: a 2 dB cable has NF 2 dB. Cooling it lowers its noise; that's why radio telescopes cool their feeds.

## Measuring noise: the Y-factor method

A calibrated noise source switches between a hot temperature $T_h$ and a cold one $T_c$ (often 290 K). The ratio of the output noise powers, $Y = N_h/N_c$, gives

$$T_e = \frac{T_h - YT_c}{Y - 1}$$

With $T_c = T_0$ and the source's excess noise ratio ENR = $10\log\frac{T_h - T_0}{T_0}$: NF = ENR − 10 log(Y − 1) in dB.

## Sensitivity

The weakest signal a receiver can detect with a required SNR:

$$S_\text{min}\text{ (dBm)} = -174 + 10\log B + \text{NF} + \text{SNR}_\text{min}$$

(B in Hz). With an antenna of noise temperature $T_A$, the system temperature is $T_\text{sys} = T_A + T_e$ and the noise power is $kT_\text{sys}B$.
:::

::: example
## Find the noise figure of an LNA (NF 1 dB, gain 20 dB), a mixer (NF 7 dB, conversion loss 7 dB) and an IF amplifier (NF 3 dB) in cascade. What does a 1 dB cable before the LNA do?

::: solution
1. **Cascade noise factor.**
   $$\begin{aligned} F &= 1.259 + \frac{5.012 - 1}{100} \\ &\quad + \frac{1.995 - 1}{100 \times 0.1995} \\ &= 1.259 + 0.040 + 0.050 \\ &= 1.349 \end{aligned}$$
2. **Noise figure and temperature.** That's NF = 1.30 dB and $T_e$ = 101 K.
3. **Add the cable.** A 1 dB cable at 290 K multiplies F by 1.259: NF = 2.30 dB and $T_e$ = 202 K, twice the noise temperature.

**Answer:** the cascade's noise figure is 1.30 dB ($T_e$ = 101 K); the 1 dB cable raises it to 2.30 dB and doubles $T_e$ to 202 K.
:::
:::

::: example
## A noise source with ENR 15 dB gives a Y-factor of 12 dB on an amplifier. What's the amplifier's noise figure?

::: solution
1. **Hot temperature.**
   $$\begin{aligned} T_h &= 290(1 + 10^{1.5}) \\ &= 9461\ \text{K} \end{aligned}$$
2. **Y-factor.** 12 dB is Y = 15.85.
3. **Noise temperature.**
   $$\begin{aligned} T_e &= \frac{9461 - 15.85 \times 290}{14.85} \\ &= 328\ \text{K} \end{aligned}$$
4. **Noise figure.**
   $$\begin{aligned} \text{NF} &= 10\log(1 + 328/290) \\ &= 3.28\ \text{dB} \end{aligned}$$
5. **Check with the shortcut.** It gives the same:
   $$15 - 10\log(14.85) = 3.28\ \text{dB}$$

**Answer:** 3.28 dB.
:::
:::

::: example
## A radio telescope's LNA has $T_e$ = 20 K and sits behind a feed with 0.2 dB of loss. What does the feed add at room temperature, and if it is cooled to 20 K? The sky contributes 10 K.

::: solution
1. **Feed loss.**
   $$\begin{aligned} L &= 10^{0.02} \\ &= 1.047 \end{aligned}$$
2. **Feed at 290 K.** It adds its own noise and scales the LNA's:
   $$\begin{aligned} (L - 1)T &= 13.7\ \text{K} \\ 1.047 \times 20 &= 20.9\ \text{K} \end{aligned}$$
   34.6 K in all, and a system temperature of 44.6 K with the sky.
3. **Feed cooled to 20 K.** The feed adds only 0.9 K: 21.9 K, and 31.9 K with the sky.
4. **Integration time.** Cooling a fifth of a decibel of loss cuts the integration time for a given sensitivity by
   $$(44.6/31.9)^2 = 2.0$$
   which is why observatories cool everything in front of the first amplifier.

**Answer:** at room temperature the feed adds 13.7 K and raises the LNA's share to 20.9 K, for a 44.6 K system; cooled to 20 K it adds only 0.9 K, for a 31.9 K system and half the integration time.
:::
:::

::: check
given: N = 0.5 | 1.2 | 3 | 6
answer: 290*(10^(N/10) - 1)
unit: K
tolerance: 0.5%

## What's the equivalent noise temperature of an amplifier with a {N} dB noise figure?

::: right
Right. $T_0(F - 1)$ = {answer} K.
:::

::: misses
- [290*10^(N/10)] Subtract 1: F = 1 means a noiseless amplifier.
- [any] Not yet. $T_e = 290(10^{NF/10} - 1)$.
:::
:::

::: check
given: a = 0.6 | 1.5 | 2.5; G = 10 | 12; b = 8 | 12
answer: 10*log(10^(a/10) + (10^(b/10) - 1)/10^(G/10))
unit: dB
tolerance: 0.05

## An amplifier with NF {a} dB and gain {G} dB feeds a stage with NF {b} dB. What's the cascade's noise figure?

::: right
Right. $F_1 + (F_2 - 1)/G_1$ = {answer} dB.
:::

::: misses
- [a + b - G] Combine noise factors as ratios, not decibels.
- [10*log(10^(a/10) + 10^(b/10)/10^(G/10))] Subtract 1 from the second stage's noise factor.
- [any] Not yet. Friis: $F = F_1 + (F_2 - 1)/G_1$.
:::
:::

::: check
given: L = 0.5 | 2 | 6; T = 20 | 77 | 400
answer: (10^(L/10) - 1)*T
unit: K
tolerance: 0.5%

## A matched {L} dB attenuator sits at a physical temperature of {T} K. What's its equivalent noise temperature?

::: right
Right. $(L - 1)T$ = {answer} K.
:::

::: misses
- [(10^(L/10) - 1)*290] The attenuator's noise depends on its own physical temperature.
- [10^(L/10)*T] Use L − 1.
- [any] Not yet. $T_e = (L - 1)T$.
:::
:::

::: check
given: E = 5 | 15 | 25; Y = 3 | 8 | 15
answer: E - 10*log(10^(Y/10) - 1)
unit: dB
tolerance: 0.05

## A noise source of ENR {E} dB produces a Y-factor of {Y} dB. What's the noise figure?

::: right
Right. ENR − 10 log(Y − 1) = {answer} dB.
:::

::: misses
- [E - Y] Convert Y to a ratio and subtract 1 first.
- [any] Not yet. NF = ENR − 10 log(Y − 1), with Y as a ratio.
:::
:::

::: check
given: B = 10 | 200 | 20000; N = 2 | 5 | 8; S = 6 | 10 | 15
answer: -174 + 10*log(B*1000) + N + S
unit: dBm
tolerance: 0.05

## A receiver has {B} kHz bandwidth, {N} dB noise figure and needs {S} dB SNR. What's its sensitivity?

::: right
Right. −174 + 10 log B + NF + SNR = {answer} dBm.
:::

::: misses
- [-174 + 10*log(B) + N + S] B must be in hertz.
- [-174 + 10*log(B*1000) + N] Add the required SNR.
- [any] Not yet. $-174 + 10\log B + \text{NF} + \text{SNR}_\text{min}$.
:::
:::

::: check
given: A = 20 | 50 | 150; N = 0.4 | 1 | 2
answer: A + 290*(10^(N/10) - 1)
unit: K
tolerance: 0.5%

## An antenna with noise temperature {A} K feeds a receiver with {N} dB noise figure. What's the system noise temperature?

::: right
Right. $T_A + T_e$ = {answer} K.
:::

::: misses
- [A + 290*10^(N/10)] The receiver contributes $T_e = 290(F - 1)$.
- [any] Not yet. $T_\text{sys} = T_A + 290(F - 1)$.
:::
:::

::: check
kind: parts
given: L = 0.5 | 1 | 2; T = 77 | 290; N = 0.5 | 1 | 3

## A line with {L} dB of loss at {T} K feeds an amplifier with a {N} dB noise figure.

::: part
answer: (10^(L/10) - 1)*T + 10^(L/10)*290*(10^(N/10) - 1)
unit: K
tolerance: 0.5%

### What is the pair's equivalent noise temperature?

::: misses
- [(10^(L/10) - 1)*T + 290*(10^(N/10) - 1)] The amplifier's noise is referred back through the loss: multiply it by L.
- [any] $(L - 1)T + LT_{e2}$.
:::
:::

::: part
answer: 10*log(1 + ((10^(L/10) - 1)*T + 10^(L/10)*290*(10^(N/10) - 1))/290)
unit: dB
tolerance: 0.5%

### What is its noise figure?

::: misses
- [any] $10\log_{10}(1 + T_e/290)$.
:::
:::
:::

::: check
kind: derivation
vars: L = 1..4, T = 4..300, t = 10..1000

## A matched attenuator of loss ratio L at temperature T precedes an amplifier with noise temperature t.

::: step
answer: (L - 1)*T

### What is the attenuator's noise temperature?
:::

::: step
answer: (L - 1)*T + L*t

### What is the pair's?
:::

::: step
answer: 1 + ((L - 1)*T + L*t)/290

### What is the pair's noise factor?
:::

::: right
Right. Loss in front of an amplifier counts twice: its own noise, and the amplifier's noise multiplied by L.
:::
:::

::: explain
## Why does loss in front of a receiver's first amplifier hurt so much more than loss after it?

::: model
A lossy cable at room temperature does two things: it weakens the signal by its loss and it adds thermal noise of its own, so that what comes out has its signal-to-noise ratio degraded by exactly the loss. That degradation happens before any amplification, so nothing later can undo it, and the system's noise figure rises decibel for decibel. The same cable placed after a high-gain amplifier sees a signal and a noise floor both already raised by the gain. Its own added noise is then tiny compared with the amplified noise passing through it, so it barely changes the ratio. In Friis's formula, the cable's contribution is divided by all the gain in front of it.
:::
:::

::: practice

::: check
given: N = 0.5 | 0.8 | 1.5 | 2 | 3 | 4
answer: 290*(10^(N/10) - 1)
unit: K
tolerance: 0.5%

## $T_e$ for NF {N} dB?

::: misses
- [any] $290(F - 1)$.
:::
:::

::: check
given: a = 1 | 2; G = 12 | 22; b = 8 | 12
answer: 10*log(10^(a/10) + (10^(b/10) - 1)/10^(G/10))
unit: dB
tolerance: 0.05

## Cascade NF: {a} dB, {G} dB gain, then {b} dB?

::: misses
- [any] $F_1 + (F_2 - 1)/G_1$.
:::
:::

::: check
given: B = 30 | 5000; N = 3 | 7; S = 8 | 12
answer: -174 + 10*log(B*1000) + N + S
unit: dBm
tolerance: 0.05

## Sensitivity: {B} kHz, NF {N} dB, SNR {S} dB?

::: misses
- [any] $-174 + 10\log B + \text{NF} + \text{SNR}$.
:::
:::
:::