S6 · Lesson 31 · Nonlinearity and intermodulation

Power-series models, harmonics, gain compression, third-order intermodulation and the intercept point, cascades and spurious-free dynamic range

Noise sets the weakest signal a receiver can hear; nonlinearity sets the strongest it can handle. No amplifier is perfectly linear, and when two strong signals pass through one, its curvature mixes them into new frequencies. Some of those, the third-order products at 2f1−f2 and 2f2−f1, land right next to the original signals, inside the band, where no filter can remove them. A strong station on one channel and another two channels away can together create interference on the channel between them. The third-order intercept point puts a single number on how well a component resists this, and with the noise figure it sets a receiver's dynamic range.

  • Output power against input power for an amplifier of gain G and input intercept point IIP3: the ideal linear output (dotted), the output compressed by a cubic term (solid) and the third-order intermodulation products of a two-tone test (dashed).
  • The IM3 products rise 3 dB for every 1 dB of input. Extended, the two straight lines meet at the intercept point, input IIP3, output IIP3 + G.
  • The 1 dB compression point sits 9.6 dB below the intercept for a cubic nonlinearity.

Predict

In a two-tone test, the input tones drop by 10 dB each. By how much do the third-order intermodulation products fall?

Name it

Power-series model

Write the output as vo=a1vi+a2vi2+a3vi3+⋯.

  • One tone Acos⁡ωt: harmonics at 2ω (from a2) and 3ω (from a3), and the fundamental becomes (a1+34a3A2)A. With a3 opposite in sign to a1, the gain falls: gain compression. The 1 dB compression point P1dB is where the gain has dropped by 1 dB.
  • Two tones at ω1,ω2: second-order products at ω1±ω2 (usually out of band) and third-order products at 2ω1−ω2 and 2ω2−ω1, close to the signals, of amplitude 34a3A3.

The third-order intercept

The fundamental grows 1 dB per dB, the IM3 products 3 dB per dB; their straight-line extensions meet at the third-order intercept, IIP3 at the input and OIP3 = IIP3 + G at the output. From one measurement:

OIP3=Pout+Pout−PIM32,PIM3=G+3Pin−2IIP3

(all per tone, in dBm). For a pure cubic, input P1dB ≈ IIP3 − 9.6 dB.

Cascades and dynamic range

Referred to the input, with powers in milliwatts:

1IIP3=1IIP31+G1IIP32+G1G2IIP33+⋯

Gain in front helps noise (Friis) but hurts linearity, so the two pull the design in opposite directions. Spurious-free dynamic range is the range of input powers over which the signal is above the noise floor while the IM3 products stay below it:

SFDR=23(IIP3−Nfloor),Nfloor=−174+10log⁡B+NF (dBm)

Worked example

A two-tone test puts −20 dBm per tone into an amplifier with 15 dB gain. The IM3 products appear at −65 dBm. Find OIP3, IIP3 and the input P1dB.

Show the solution
  1. Output level. Pout=−5dBm which is 60 dB above the products.
  2. OIP3. OIP3=−5+60/2=25dBm
  3. IIP3. IIP3=25−15=10dBm
  4. Input P1dB. P1dB≈10−9.6=0.4dBm
  5. Check. At −20 dBm in, PIM3=15−60−20=−65dBm

Answer OIP3 = 25 dBm, IIP3 = 10 dBm and the input P1dB is about 0.4 dBm.

Worked example

An LNA (gain 15 dB, IIP3 0 dBm) drives a mixer (IIP3 +10 dBm). What's the cascade's IIP3, and its SFDR with a 3 dB noise figure in 1 MHz?

Show the solution
  1. Cascade IIP3. 1IIP3=11 mW+31.610 mW=4.16mW−1
  2. In dBm. The mixer, behind 15 dB of gain, dominates: IIP3=0.240mW=−6.2dBm
  3. Noise floor. N=−174+60+3=−111dBm
  4. SFDR. SFDR=23(−6.2+111)=69.9dB

Answer the cascade's IIP3 is −6.2 dBm and its SFDR 69.9 dB.

Worked example

An amplifier with 20 dB gain and OIP3 = +30 dBm receives two tones of −10 dBm each. How far below the tones are the IM3 products, and what happens if each tone rises by 5 dB?

Show the solution
  1. Output level. Each tone leaves at +10 dBm.
  2. IM3 products. They sit 40 dB below the tones: 3Pout−2OIP3=30−60=−30dBm The carrier-to-IM ratio is 2(OIP3−Pout).
  3. Tones 5 dB stronger. At +15 dBm out, the products rise to −15 dBm, only 30 dB down: 5 dB more signal costs 10 dB of spectral purity, which is why transmitters back off from compression.

Answer the IM3 products are 40 dB below the tones; with each tone 5 dB stronger they are only 30 dB down.

Check

In a two-tone test the output is −5 dBm per tone and the IM3 products are at −80 dBm. What's OIP3?

Check

An amplifier with gain 20 dB and IIP3 of 15 dBm receives two tones of −40 dBm each. At what level are the IM3 products?

Check

A stage with IIP3 0 dBm and gain 10 dB drives a stage with IIP3 18 dBm. What's the cascade's IIP3?

Check

A receiver has IIP3 −5 dBm, 10 dB noise figure and 0.03 MHz bandwidth. What's its spurious-free dynamic range?

Check

Two tones at 2400 MHz and 2400 + 0.2 MHz pass through an amplifier. Where is the lower third-order product?

Write units the way you normally would: 1.5 MHz, 1500 kHz and 0.0015 GHz are the same answer.

Check

A component's nonlinearity is a pure cubic with IIP3 = 3 dBm. Where is its input 1 dB compression point?

Check

An amplifier with OIP3 = 30 dBm and 10 dB of gain receives two tones of −10 dBm each.

(a)

At what level are the output IM3 products?

(b)

How far below each tone are they?

Check

An amplifier with gain G (dB) and IIP3 I (dBm) receives two tones of P dBm each.

Step 1

What output power does each tone have?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why can't a filter remove the third-order intermodulation products of two nearby strong signals?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.