S6 · Lesson 2 · Scattering parameters
Incident and reflected waves, the S matrix, return and insertion loss, lossless and reciprocal networks, and shifting reference planes
Open and short circuits, which Z and Y matrices need, are hard to make at microwave frequencies: a "short" has inductance, an "open" radiates, and an amplifier tested that way may oscillate. What a network analyzer can measure cleanly is how waves sent into each port, with every other port terminated in a matched load, are reflected and transmitted. That's the scattering matrix, S, and it's the language of every microwave datasheet. Its entries read directly as physical quantities: |S₁₁|² is the fraction of power reflected, |S₂₁|² the fraction transmitted, and for a lossless network the two add to one.
- A resistor R in series between two lines of impedance : the fraction of incident power reflected (, solid), transmitted (, dashed) and absorbed in the resistor (dotted line), against .
- and . Small R passes almost everything; large R reflects almost everything.
- The resistor absorbs of the power, at most half, when .
Predict
A 50 Ω resistor is placed in series between two 50 Ω lines. What fraction of the incident power reaches the far side?
= 100/150 = 2/3, so = 4/9 = 44% gets through (3.5 dB insertion loss). = 50/150 = 1/3 reflects 1/9, and the resistor absorbs the remaining 4/9. The return loss is 9.5 dB and the VSWR is 2.
Name it
Waves and the S matrix
At port n, the voltage is the sum of an incident wave and a reflected wave . The scattering matrix relates them:
measured with every other port terminated in its characteristic impedance (matched), so nothing comes back into it. is the input reflection coefficient; the forward transmission coefficient.
Reading S in decibels
- Return loss ; VSWR = .
- Insertion loss (for a passive network).
Properties
- Reciprocal: is symmetric, .
- Lossless: is unitary, . Each column has unit length: for a two-port, and different columns are orthogonal.
- From Z: (equal at all ports).
Simple two-ports
- Series impedance Z: , .
- Shunt admittance Y: , .
Shifting a reference plane
Moving port n's reference plane outward by a line of electrical length multiplies by : a reflection coefficient's phase changes by , a transmission's by .
Worked example
A series 50 Ω resistor between 50 Ω lines: find S₁₁, S₂₁, return loss, VSWR, insertion loss and the power it absorbs.
Show the solution
- S-parameters.
- Return loss.
- VSWR.
- Insertion loss.
- Absorbed power. The fraction of the incident power absorbed is
- Compare with a lossless network. A lossless network couldn't absorb anything: its S₁₁ and S₂₁ would satisfy
Answer S₁₁ = 1/3 and S₂₁ = 2/3, giving a 9.5 dB return loss, a VSWR of 2 and a 3.5 dB insertion loss, and the resistor absorbs 4/9 of the incident power.
Worked example
A lossless reciprocal two-port has |S₁₁| = 0.6. What's |S₂₁|? If S₁₁ = 0.6∠30° at one plane, what is it after moving the port-1 plane 45° of line farther out?
Show the solution
- Transmission. so 64% of the power gets through and 36% reflects.
- Move the plane. Moving the plane changes the phase by :
- Magnitude. Its magnitude doesn't change; a lossless line only delays the wave.
Answer |S₂₁| = 0.8, and after the move S₁₁ becomes 0.6∠−60°.
Worked example
A 100 Ω resistor is shunted across a 50 Ω line, with matched ports on both sides. Find S₁₁, S₂₁, the return and insertion losses, and the fraction of power it absorbs.
Show the solution
- Normalized admittance.
- S-parameters.
- Return loss.
- Insertion loss.
- Absorbed power. The network isn't lossless, so and the resistor absorbs the remaining 32% of the incident power.
Answer S₁₁ = −0.2 and S₂₁ = 0.8, with a 14.0 dB return loss and a 1.94 dB insertion loss, and the resistor absorbs 32% of the incident power.
Check
A port has |S₁₁| = 0.2. What's its return loss?
Check
A port has |S₁₁| = 0.2. What's its VSWR?
Check
A lossless two-port has |S₁₁| = 0.6. What's |S₂₁|?
Check
A resistor of 50 Ω sits in series between two 50 Ω lines. What's S₁₁?
Check
A resistor of 50 Ω is shunted across a 50 Ω line, with matched ports on both sides. What's S₂₁?
Check
S₁₁ has a phase of 60°. The port-1 reference plane is moved outward by 15° of lossless line. What's the new phase (unreduced)?
Check
A 50 Ω resistor sits in series between two matched 50 Ω lines.
(a)
What is S₂₁?
(b)
What is the insertion loss?
(c)
What fraction of the incident power does the resistor absorb?
Check
A resistance R is shunted across a line of impedance Z, matched on both sides.
Step 1
What is S₁₁?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What is S₂₁?
Step 3
What fraction of the incident power does it absorb?
Explain why
Why do microwave engineers characterize networks with S-parameters instead of Z or Y parameters?
Z and Y parameters are defined with the other ports open or shorted. At microwave frequencies those terminations are hard to realize, since a short has inductance and an open radiates, and they change along the line, so the measurement depends on exactly where they sit. Worse, an amplifier presented with an open or short often oscillates. S-parameters are defined with every port terminated in its characteristic impedance, which a matched load provides accurately over a wide band, and they're ratios of traveling waves, which a directional coupler can separate and a network analyzer can measure directly. They also read as physical quantities, fractions of power reflected and transmitted, and moving a reference plane along a line only changes their phase.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.