S6 · Lesson 12 · Tapered lines and the Bode–Fano limit
Continuous tapers, the exponential taper's response, and the fundamental bound on how wide a match can be
Take the multisection transformer to its limit and the steps merge into a smooth taper: a line whose impedance changes continuously from one value to the other. Long enough tapers match over enormous bandwidths, decades in frequency, which is why horn antennas flare and why broadband baluns taper. But no matching network can do everything: Bode and Fano proved that a load containing reactance, such as an antenna's capacitance or a transistor's input, can only be matched well over a limited band, however clever the network. Knowing that limit tells a designer when to stop trying.
- Reflection against taper length in wavelengths for an exponential taper from 50 Ω to : (small-reflection theory).
- Short tapers reflect like an abrupt step; at L = λ/2 the reflection vanishes, and beyond it the sidelobes never exceed 22% of the low-frequency value.
- A taper is a highpass match: any frequency high enough to make it long in wavelengths is matched.
Predict
A load is 50 Ω in parallel with 1 pF. Over what bandwidth, at most, can any lossless network match it to a 50 Ω source with |Γ| ≤ 0.1?
Bode–Fano: , so = = 4.3 GHz. Accepting a worse match, |Γ| ≤ 0.316 (10 dB return loss), doubles it to 8.7 GHz. No network beats this; it's a property of the load.
Name it
Tapered lines
For a line whose impedance Z(z) varies smoothly from at z = 0 to at z = L, small-reflection theory gives
- Exponential taper, with : , zero at L = λ/2, λ, …; its impedance at the midpoint is .
- Triangular tapers lower the sidelobes; the Klopfenstein taper is optimal, giving the lowest passband reflection for a given length (it's the limit of a Chebyshev transformer).
The Bode–Fano limit
For a load of resistance R with parallel capacitance C, any lossless matching network satisfies
For an ideal response, over a band Δω and 1 elsewhere:
A series R–L load has the same bound with π/RC replaced by πR/L. Better match means less bandwidth, and a perfect match (Γ = 0) is possible only at isolated frequencies.
Worked example
An exponential taper matches 100 Ω to 50 Ω. What's its reflection at low frequency, at L = λ/2, and at its worst beyond that?
Show the solution
- Low frequency. The taper reflects like an abrupt step (the exact step reflection is 1/3):
- At L = λ/2. The reflection is zero.
- Largest sidelobe beyond. It sits at βL = 4.49 (L = 0.715λ):
- Longer tapers. Once the taper is longer than about 0.41λ, the reflection never again exceeds 0.075 (SWR 1.16) at any higher frequency.
Answer 0.347 at low frequency, zero at L = λ/2, and at worst 0.075 beyond that.
Worked example
A 50 Ω load with 1 pF in parallel needs |Γ| ≤ 0.1. What's the widest band any network can achieve, and with |Γ| ≤ 0.316?
Show the solution
- Time constant.
- Limit for Γm = 0.1.
- Limit for Γm = 0.316. The same bound gives 8.69 GHz.
- What the limit means. Real networks with a finite number of elements fall short of these bounds; the Bode–Fano limit is the target they approach.
Answer no network can do better than 4.34 GHz with |Γ| ≤ 0.1, or 8.69 GHz with |Γ| ≤ 0.316.
Worked example
A load of 10 Ω in series with 5 nH must be matched with |Γ| ≤ 0.2. What is the widest band any network can achieve?
Show the solution
- The bound for a series R–L load.
- Solve for the bandwidth.
- A tighter match. Asking for |Γ| ≤ 0.1 instead cuts it to 434 MHz.
- What helps. No cleverness in the matching network beats this: only reducing L (a smaller package, a shorter bond wire) does.
Answer about 621 MHz.
Check
An exponential taper matches 150 Ω to 50 Ω. What's |Γ| at βL = 1 rad?
Check
How long must an exponential taper be for its first reflection null at 3 GHz, on a line with = 1?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
Check
A load of 50 Ω in parallel with 0.3 pF must be matched with |Γ| ≤ 0.316. What's the Bode–Fano limit on the bandwidth?
Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.
Check
A load of 25 Ω in parallel with 0.5 pF must be matched over 3 GHz. What's the smallest |Γ| any network can keep across that band?
Check
A series load of 10 Ω and 2 nH must be matched with |Γ| ≤ 0.2. What's the widest possible bandwidth?
Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.
Check
An exponential taper runs from 50 Ω to 120 Ω. What's its impedance at the midpoint?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
An exponential taper 3 cm long on a line with = 6.5 runs from 50 Ω to 100 Ω; the frequency is 5 GHz.
(a)
What is βL?
Write units the way you normally would: 1.5 rad and 1500 mrad are the same answer.
(b)
What is |Γ|?
Check
A load is either R in parallel with C or R in series with L, and must be matched with |Γ| ≤ g.
Step 1
What is the widest Δω for the parallel R–C load?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
And in hertz?
Step 3
What is the widest Δω for the series R–L load?
Explain why
Why can't a reactive load be matched perfectly over a wide band, however complicated the matching network?
A load such as a resistor with a capacitor across it stores energy in its reactance, and that stored energy limits how quickly its impedance can be transformed across frequency. Bode and Fano showed, by applying contour integration to the reflection coefficient of any lossless network driving such a load, that the integral of the logarithm of 1/|Γ| over all frequencies is fixed by the load alone, π/RC for the parallel RC. That integral is a budget: spending it on a very good match (large ln 1/|Γ|) leaves only a narrow band, and spreading it over a wide band allows only a mediocre match. A perfect match, with ln 1/|Γ| infinite, can only exist at isolated frequencies. Matching networks can approach the bound but never exceed it, so the load, not the network, decides what's possible.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.