title: Network analyzer calibration
heading: How a vector network analyzer measures, the one-port error model, short–open–load calibration, two-port models, TRL and residual uncertainty
eyebrow: S6 · Lesson 45 · Network analyzer calibration
xp: 50
---

::: hook
A vector network analyzer measures S-parameters to a hundredth of a decibel, but only after it's been told what its own cables, connectors and couplers are doing. Raw, its readings are distorted by imperfect directivity (lesson 18), mismatches at its ports and frequency-dependent losses, and at microwave frequencies those errors can be larger than what's being measured. Calibration measures a few known standards, solves for the errors, and removes them mathematically from every later measurement. The error model is only a few lines of algebra, and it's the reason modern RF design can trust its numbers.
:::

::: play
- Reflection measured by an uncorrected one-port, against the phase of the device's reflection (as if the device sat at the end of a sliding line), for a device whose true return loss is R dB.
- The analyzer's raw directivity and source match make the reading ripple around the truth (dashed) as the phases line up and cancel.
- Improve the directivity or source match, or measure a worse load, and the ripple shrinks. Calibration removes it altogether, leaving only residual errors.
:::
:::

```sim plot
view: graph
x: p = 0..6.2832
y: G = -50..0 dB
slider: R = 5..40 = 20 dB
slider: D = 15..50 = 25 dB
slider: S = 10..40 = 18 dB
plot: 20*log(abs(10^(-D/20) + 10^(-R/20)*exp(j*p)/(1 - 10^(-S/20)*exp(j*1)*10^(-R/20)*exp(j*p)))) | samples: 600 | label: raw reading, dB
plot: -R | dashed | color: ch3 | label: true reflection
```

::: predict
## How many known standards does a one-port calibration need, at minimum?

- [ ] One: a matched load
- [ ] Two: a short and an open
- [x] Three, such as a short, an open and a load
- [ ] Twelve

::: reveal
Three. The one-port error model has three unknown complex terms, directivity, source match and reflection tracking, so three independent known reflections pin them down. Short, open and load is the usual set; three offset shorts work too. A full two-port model has twelve terms (or eight, in the form TRL uses), found by adding a through connection and transmission measurements.
:::
:::

::: nameit
## The VNA

A source sweeps frequency; directional couplers or bridges at each port sample the incident and reflected waves ($a_1, b_1, a_2, b_2$); receivers down-convert them and measure their ratios in magnitude and phase. $S_{11} = b_1/a_1$ with port 2 terminated, and so on.

## The one-port error model

Everything between the analyzer's ideal reflectometer and the device is lumped into an error two-port with three terms:

- $e_{00}$, **directivity** (leakage straight to the reflected-wave receiver);
- $e_{11}$, **source match** (what the device sees looking back);
- $e_{10}e_{01}$, **reflection tracking** (loss and phase of the path).

The measured reflection is

$$\Gamma_M = e_{00} + \frac{e_{10}e_{01}\Gamma_A}{1 - e_{11}\Gamma_A}$$

which is lesson 4's terminated two-port.

## Short–open–load calibration

Measure a load (Γ = 0), an open (Γ = +1) and a short (Γ = −1), giving $M_L$, $M_O$, $M_S$. With $a = M_O - M_L$ and $b = M_S - M_L$:

$$e_{00} = M_L, \qquad e_{11} = \frac{a + b}{a - b}, \qquad e_{10}e_{01} = a(1 - e_{11})$$

and any later measurement is corrected by inverting the model:

$$\Gamma_A = \frac{\Gamma_M - e_{00}}{e_{10}e_{01} + e_{11}(\Gamma_M - e_{00})}$$

(Real standards aren't ideal: the open's fringing capacitance and the short's inductance are described by the calibration kit's model.)

## Two ports, TRL and residual errors

- **SOLT** adds a thru and gives the 12-term model (6 per direction: directivity, source match, reflection tracking, load match, transmission tracking, isolation).
- **TRL** (thru, reflect, line) needs no well-known load: a thru, any high reflection (the same on both ports) and a line whose extra length differs from the thru by between about 20° and 160°, which limits one line to an 8 : 1 band. It's the standard for on-wafer and in-fixture work.
- After calibration, **residual** directivity, source match and tracking, set by how well the standards are known, determine the uncertainty, and cable flexing and drift spoil a calibration over time.
:::

::: example
## A one-port calibration measures $M_L$ = 0.05, $M_O$ = 0.80 and $M_S$ = −0.90 (real, for simplicity). Find the error terms and correct a reading of 0.30.

::: solution
1. **Directivity.**
   $$\begin{aligned} e_{00} &= M_L \\ &= 0.05 \end{aligned}$$
2. **Source match.** With a = 0.75 and b = −0.95,
   $$\begin{aligned} e_{11} &= \frac{0.75 - 0.95}{0.75 + 0.95} \\ &= -0.118 \end{aligned}$$
3. **Reflection tracking.**
   $$\begin{aligned} e_{10}e_{01} &= 0.75 \times 1.118 \\ &= 0.838 \end{aligned}$$
4. **Correct the reading.**
   $$\begin{aligned} \Gamma_A &= \frac{0.30 - 0.05}{0.838 - 0.118 \times 0.25} \\ &= 0.309 \end{aligned}$$
5. **Check.**
   $$\begin{aligned} &0.05 + \frac{0.838 \times 0.309}{1 + 0.118 \times 0.309} \\ &= 0.300 \end{aligned}$$

**Answer:** $e_{00}$ = 0.05, $e_{11}$ = −0.118 and $e_{10}e_{01}$ = 0.838, and the device's corrected reflection is 0.309.
:::
:::

::: example
## A TRL line has 90° more delay than the thru at 5 GHz. Over what band is it usable?

::: solution
1. **Phase limits.** The line's extra phase scales with frequency, so 20° and 160° are reached at
   $$\begin{aligned} 5 \times 20/90 &= 1.11\ \text{GHz} \\ 5 \times 160/90 &= 8.89\ \text{GHz} \end{aligned}$$
2. **Band.** That's an 8 : 1 band.
3. **Wider bands.** They use several lines, each covering part of the band.

**Answer:** from 1.11 to 8.89 GHz, an 8 : 1 band.
:::
:::

::: example
## After calibration, an analyzer's residual directivity is −40 dB and its residual source match −35 dB. It measures a load whose true return loss is 20 dB. What could it read?

::: solution
1. **True reflection.** The true |Γ| is 0.1.
2. **Worst-case error.** It is about
   $$\begin{aligned} &e_{00} + e_{11}|\Gamma|^2 \\ &= 0.010 + 0.0178 \times 0.01 \\ &= 0.0102 \end{aligned}$$
3. **Range of readings.** The reading lies between 0.0898 and 0.1102: a return loss between 19.2 and 20.9 dB.
4. **Which term matters.** Directivity dominates when measuring good matches, and source match when measuring large reflections, which is why calibration kits specify both.

**Answer:** a return loss anywhere from 19.2 to 20.9 dB.
:::
:::

::: check
given: L = 0.02 | 0.08; O = 0.75 | 0.9; S = -0.8 | -0.95
answer: ((O - L) + (S - L))/((O - L) - (S - L))
tolerance: 0.5%

## A one-port calibration measures {L} on the load, {O} on the open and {S} on the short (real). What's the source match $e_{11}$?

::: right
Right. $(a + b)/(a - b)$ with $a = M_O - M_L$ and $b = M_S - M_L$: {answer}.
:::

::: misses
- [(O + S)/(O - S)] Subtract the directivity, $M_L$, from both first.
- [any] Not yet. Solve the model at Γ = +1 and Γ = −1 after removing $e_{00}$.
:::
:::

::: check
given: L = 0.02 | 0.08; O = 0.75 | 0.9; S = -0.8 | -0.95
answer: (O - L)*(1 - ((O - L) + (S - L))/((O - L) - (S - L)))
tolerance: 0.5%

## With the same measurements, what's the reflection tracking $e_{10}e_{01}$?

::: right
Right. $a(1 - e_{11})$ = {answer}.
:::

::: misses
- [O - L] Correct for the source match: multiply by $1 - e_{11}$.
- [any] Not yet. From the open: $a = e_{10}e_{01}/(1 - e_{11})$.
:::
:::

::: check
given: d = 0.02 | 0.06; e = -0.15 | 0.1; t = 0.8 | 0.9; M = 0.2 | 0.5 | -0.4
answer: (M - d)/(t + e*(M - d))
tolerance: 0.5%

## A calibrated one-port has $e_{00}$ = {d}, $e_{11}$ = {e} and $e_{10}e_{01}$ = {t} (real). It reads {M}. What's the device's actual reflection?

::: right
Right. $(\Gamma_M - e_{00})/(e_{10}e_{01} + e_{11}(\Gamma_M - e_{00}))$ = {answer}.
:::

::: misses
- [(M - d)/t] Include the source-match term in the denominator.
- [M - d] Also divide out the tracking and source match.
- [any] Not yet. Invert the three-term model.
:::
:::

::: check
given: d = 0.02 | 0.06; e = -0.15 | 0.1; t = 0.8 | 0.95; G = 0.1 | 0.4 | -0.6
answer: d + t*G/(1 - e*G)
tolerance: 0.5%

## An uncorrected one-port has $e_{00}$ = {d}, $e_{11}$ = {e} and $e_{10}e_{01}$ = {t} (real). What does it read for a device with Γ = {G}?

::: right
Right. $e_{00} + e_{10}e_{01}\Gamma_A/(1 - e_{11}\Gamma_A)$ = {answer}.
:::

::: misses
- [d + t*G] Include the multiple reflections between the device and the source match.
- [any] Not yet. The three-term error model.
:::
:::

::: check
given: f = 2 | 5 | 20; a = 20 | 30; b = 150 | 160
answer: f*b/90
unit: GHz
tolerance: 0.5%

## A TRL line has 90° more delay than the thru at {f} GHz, and the cal is trusted while the phase difference stays between {a}° and {b}°. What's the highest usable frequency?

::: right
Right. {f} × {b}/90 = {answer} GHz.
:::

::: misses
- [f*a/90] That's the lowest usable frequency.
- [any] Not yet. The extra phase scales with frequency.
:::
:::

::: check
given: f = 1 | 4 | 12; g = 3 | 8; e = 1 | 2.9 | 6.5
answer: 299.792458/(4*(f*(1 + g)/2)*sqrt(e))
unit: mm
tolerance: 0.5%

## A TRL line must cover {f} to {f} × {g} GHz, so it's made a quarter wave long at the band's arithmetic center. How much longer than the thru is it, on a line with $\varepsilon_\text{eff}$ = {e}?

::: right
Right. A quarter wave at $(f_1 + f_2)/2$: {answer} mm.
:::

::: misses
- [299.792458/(4*f*sqrt(e))] Use the center of the band, not its lower edge.
- [any] Not yet. $\lambda_g/4$ at the center frequency.
:::
:::

::: check
kind: parts
given: D = 30 | 40 | 50; S = 20 | 25; R = 6 | 10 | 14

## After calibration an analyzer has residual directivity −{D} dB and residual source match −{S} dB. It measures a load whose true return loss is {R} dB.

::: part
answer: 10^(-D/20) + 10^(-S/20)*10^(-R/10)
tolerance: 0.5%

### What is the worst-case error in |Γ|?

::: misses
- [10^(-D/20)] Source match adds $e_{11}|\Gamma|^2$.
- [any] $e_{00} + e_{11}|\Gamma|^2$.
:::
:::

::: part
answer: -20*log(10^(-R/20) + 10^(-D/20) + 10^(-S/20)*10^(-R/10))
unit: dB
tolerance: 0.5%

### What is the lowest return loss it could read?

::: misses
- [any] $-20\log_{10}$ of the true |Γ| plus the error.
:::
:::
:::

::: check
kind: derivation
vars: m = -0.2..0.2, o = 0.5..1, s = -1..-0.5

## A one-port calibration measures m on the load, o on the open and s on the short (real).

::: step
answer: m

### What is the directivity $e_{00}$?
:::

::: step
answer: ((o - m) + (s - m))/((o - m) - (s - m))

### What is the source match $e_{11}$?
:::

::: step
answer: (o - m)*(1 - ((o - m) + (s - m))/((o - m) - (s - m)))

### What is the reflection tracking $e_{10}e_{01}$?
:::

::: right
Right. Three known standards give three equations for the three error terms.
:::
:::

::: explain
## Why can a network analyzer measure a nearly perfect load accurately after calibration, when its own directivity is only 25 dB?

::: model
Raw directivity of 25 dB means a fixed leak of the forward wave reaches the reflected-wave receiver, which would swamp the reflection from a 40 dB return-loss load. But the leak is systematic: at each frequency it has a definite size and phase that doesn't change from one measurement to the next. Measuring a known load during calibration captures it as the error term $e_{00}$, and every later measurement simply has it subtracted, along with the effects of source match and tracking found from the open and short. What remains is the residual error, set by how well the calibration standards themselves are known and by drift and cable movement since the calibration, which with a good kit can correspond to an effective directivity of 40 to 50 dB.
:::
:::

::: practice

::: check
given: L = 0.03 | 0.07; O = 0.8 | 0.95; S = -0.85 | -0.98
answer: ((O - L) + (S - L))/((O - L) - (S - L))
tolerance: 0.5%

## $e_{11}$ from load {L}, open {O}, short {S}?

::: misses
- [any] $(a + b)/(a - b)$.
:::
:::

::: check
given: d = 0.03 | 0.08; e = -0.1 | 0.12; t = 0.85 | 0.92; M = 0.35 | -0.25
answer: (M - d)/(t + e*(M - d))
tolerance: 0.5%

## Corrected Γ: e₀₀ {d}, e₁₁ {e}, tracking {t}, reading {M}?

::: misses
- [any] Invert the model.
:::
:::

::: check
given: f = 3 | 10; a = 20 | 25
answer: f*a/90
unit: GHz
tolerance: 0.5%

## Lowest usable frequency for a 90° TRL line at {f} GHz with a {a}° limit?

::: misses
- [any] $f \times a/90$.
:::
:::
:::