S746 of 55
0 XP
  1. Hook
  2. Problems

S7 · Problem set 8

Problem set 8: AR models and Levinson–Durbin, Wiener filters, LMS design, the Hilbert transform and filter banks

These problems cover lessons 34 to 44: autoregressive models, prediction gain and the Levinson–Durbin recursion, scalar, noncausal and FIR Wiener filters, LMS and NLMS step sizes, convergence and misadjustment, Hilbert transformers and envelopes, cepstra, compressed sensing, and uniform DFT filter banks.

Check

An AR(1) process x[n] = 0.85x[n − 1] + w[n], noise variance 0.5.

(a)

Variance of x?

(b)

φ[2]?

(c)

PSD at ω = 2.5?

Check

A process with φ = [1, 0.5, 0.1].

(a)

k2?

(b)

a1 of the order-2 predictor?

(c)

Order-2 prediction gain?

Check

A signal of variance 2 in uncorrelated noise of variance 0.5.

(a)

Scalar Wiener gain?

(b)

Minimum mean-square error?

Check

A unit-variance AR(1) signal (a = 0.7) in white noise of density 0.3.

(a)

Noncausal Wiener gain at ω = 2?

(b)

h0 of the two-tap FIR Wiener filter?

Check

An LMS filter with 256 taps, input power 0.05, aiming for 15% misadjustment.

(a)

Trace bound on μ?

(b)

μ for the misadjustment?

(c)

Weight time constant in samples (white input)?

Check

An NLMS filter with μ~ = 0.3, 32 taps, input power 0.4; and a one-tap LMS filter with μ = 1.6 on unit-power input.

(a)

NLMS effective step?

(b)

One-tap mean weight error after 5 steps?

Check

The ideal Hilbert transformer, and its 4-tap truncation (taps at ±1 and ±3).

(a)

h[5]?

(b)

Truncated amplitude at ω = 0.6?

Check

Two tones of amplitudes 1 and 0.4, 135° apart; and a 2 kHz tone sent single-sideband on a 10700 kHz carrier.

(a)

Envelope?

(b)

Lower-sideband output frequency?

Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.

Check

A 16-channel DFT bank at 48 kHz with an N = 1024-tap prototype.

(a)

Channel spacing?

Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.

(b)

Center of channel 12?

(c)

Polyphase-FFT cost per input sample?

Check

A QMF analysis pair from H0=[1,1.5,1].

(a)

|H0| at ω = 2.2?

(b)

|H1| at ω = 2.2?

Check

An AR(1) process with a = 0.8, noise variance 1; and a band where the SNR is 10 dB.

(a)

Prediction gain?

(b)

Wiener gain in that band?

Check

An LMS filter: μ = 0.002, 32 taps, input power 1; a weight mode with eigenvalue 2, at 8 kHz.

(a)

Misadjustment?

(b)

Mode time constant?

Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.

Have paper and a calculator ready. Work each problem out by hand, then enter the answer. Your first try on each one counts toward your score.

Practice

Keep practicing

16 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.