S851 of 56
0 XP
  1. Hook
  2. Problems

S8 · Problem set 10

Problem set 10: reuse and co-channel interference, sectoring, cell splitting, Erlang B, path-loss exponents and shadowing margins, fade statistics, diversity and transmit diversity

These problems cover lessons 49 and 50 with the fading lessons behind them: frequency reuse and the SIR it allows, sectoring and cell splitting, channels and traffic under Erlang B, path-loss exponents and shadowing margins measured in the field, how often and how long a Rayleigh channel fades, and the error rates and outages of diversity schemes you simulated in the fading lab.

Check

Hexagonal cells reuse frequencies in clusters of N = 4, with path-loss exponent 3.

(a)

What is the reuse ratio D/R?

(b)

What SIR does a user at the cell edge see from the six nearest co-channel cells?

Check

Cells in clusters of N = 4 (path-loss exponent 3) are split into 6 sectors, which leaves 1 first-tier interferer(s).

(a)

What edge SIR does a sector see?

(b)

How much has sectoring gained?

Check

A system needs 14 dB of SIR at the cell edge with path-loss exponent 3.

(a)

What cluster size meets it exactly, before rounding up to a valid N?

Check

An FDD system has 25 MHz in each direction, 25 kHz per channel, and a cluster of N = 12.

(a)

How many duplex channels does the system have?

(b)

How many does each cell get?

Check

2 erlangs are offered to a group of channels whose blocked calls are lost.

(a)

What blocking does a group of 3 channels give?

(b)

And 4 channels?

Check

Each subscriber makes 2 call(s) in the busy hour averaging 1.5 minutes; a cell's channels can carry 28.1 erlangs at 2% blocking.

(a)

How much traffic does each subscriber offer?

(b)

How many subscribers can the cell serve?

Check

Cells are split into cells with 1/3 of the radius, keeping the same reuse pattern; the path-loss exponent is 3.

(a)

By what factor does the capacity per unit area grow?

(b)

How much can each base station's transmit power fall while keeping the same signal at the new cell edge?

Check

A drive test measures −60 dBm at 100 m from a base station and 40 dB less at 10 times that distance.

(a)

What path-loss exponent do the measurements show?

(b)

What would you predict at twice the farther distance?

Check

Log-normal shadowing has a standard deviation of 8 dB, and a link budget leaves 5 dB of margin at the cell edge.

(a)

What fraction of edge locations fall below the threshold?

(b)

What margin would give 90% coverage at the edge?

Check

A Rayleigh-fading envelope has a 20 Hz maximum Doppler shift; consider the level 0.3 times its rms value.

(a)

What fraction of the time is the envelope below that level?

(b)

How many times per second does it cross the level going up?

Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.

(c)

How long does an average fade below it last?

Check

A receiver moves at 3 km/h on a 2.4 GHz carrier.

(a)

After how long does the channel's autocorrelation J0(2πfdτ) first reach zero?

Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.

(b)

How far has it moved by then?

Check

BPSK runs over Rayleigh fading at 15 dB average Eb/N0 per branch.

(a)

What is the exact bit error rate with two-branch MRC?

(b)

What does Alamouti's code from two transmit antennas give at the same total power?

Have paper and a calculator ready. Work each problem out by hand, then enter the answer. Your first try on each one counts toward your score.

Practice

Keep practicing

14 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.