title: "Problem set 10: cellular systems and fading in practice"
heading: "Problem set 10: reuse and co-channel interference, sectoring, cell splitting, Erlang B, path-loss exponents and shadowing margins, fade statistics, diversity and transmit diversity"
eyebrow: S8 · Problem set 10
type: problems
---

::: hook
These problems cover lessons 49 and 50 with the fading lessons behind them: frequency reuse and the SIR it allows, sectoring and cell splitting, channels and traffic under Erlang B, path-loss exponents and shadowing margins measured in the field, how often and how long a Rayleigh channel fades, and the error rates and outages of diversity schemes you simulated in the fading lab.
:::

::: pool
pick: 12

::: check
kind: parts
given: N = 3 | 4 | 7 | 12; n = 3 | 3.5 | 4

## Hexagonal cells reuse frequencies in clusters of N = {N}, with path-loss exponent {n}.

::: part
answer: sqrt(3*N)
tolerance: 0.5%

### What is the reuse ratio D/R?

::: misses
- [any] $\sqrt{3N}$.
:::
:::

::: part
answer: 10*log(sqrt(3*N)^n/6)
unit: dB
tolerance: 0.5%

### What SIR does a user at the cell edge see from the six nearest co-channel cells?

::: misses
- [any] $(\sqrt{3N})^n/6$.
:::
:::
:::

::: check
kind: parts
given: N = 3 | 4 | 7; n = 3 | 4; s = 3 | 6; let k = 6/s

## Cells in clusters of N = {N} (path-loss exponent {n}) are split into {s} sectors, which leaves {k} first-tier interferer(s).

::: part
answer: 10*log(sqrt(3*N)^n/k)
unit: dB
tolerance: 0.5%

### What edge SIR does a sector see?

::: misses
- [10*log(sqrt(3*N)^n/6)] Sectoring removes interferers outside the antenna's beam.
- [any] $(\sqrt{3N})^n/k$.
:::
:::

::: part
answer: 10*log(6/k)
unit: dB
tolerance: 0.5%

### How much has sectoring gained?

::: misses
- [any] $10\log_{10}(6/k)$.
:::
:::
:::

::: check
kind: parts
given: S = 9 | 14 | 18; n = 3 | 3.5 | 4

## A system needs {S} dB of SIR at the cell edge with path-loss exponent {n}.

::: part
answer: (6*10^(S/10))^(2/n)/3
tolerance: 0.5%

### What cluster size meets it exactly, before rounding up to a valid N?

::: misses
- [any] Solve $(\sqrt{3N})^n/6 = \text{SIR}$: $N = (6\,\text{SIR})^{2/n}/3$.
:::
:::
:::

::: check
kind: parts
given: W = 12.5 | 25 | 60; b = 25 | 30 | 200; N = 4 | 7 | 12

## An FDD system has {W} MHz in each direction, {b} kHz per channel, and a cluster of N = {N}.

::: part
answer: W*1e3/b
unit: channels
tolerance: 0.5%

### How many duplex channels does the system have?

::: misses
- [W*1e3/b/2] With FDD each direction has its own W MHz, so a duplex channel uses b kHz of each.
- [any] $W/b$.
:::
:::

::: part
answer: W*1e3/b/N
unit: channels
tolerance: 0.5%

### How many does each cell get?

::: misses
- [any] Divide by the cluster size.
:::
:::
:::

::: check
kind: parts
given: A = 1 | 2 | 3

## {A} erlangs are offered to a group of channels whose blocked calls are lost.

::: part
answer: (A^3/6)/(1 + A + A^2/2 + A^3/6)*100
unit: %
tolerance: 0.5%

### What blocking does a group of 3 channels give?

::: misses
- [any] $\frac{A^3/3!}{\sum_{k=0}^{3}A^k/k!}$.
:::
:::

::: part
answer: (A^4/24)/(1 + A + A^2/2 + A^3/6 + A^4/24)*100
unit: %
tolerance: 0.5%

### And 4 channels?

::: misses
- [any] $\frac{A^4/4!}{\sum_{k=0}^{4}A^k/k!}$.
:::
:::
:::

::: check
kind: parts
given: c = 1 | 2 | 4; h = 1.5 | 3 | 6; A = 5.08 | 12 | 28.1

## Each subscriber makes {c} call(s) in the busy hour averaging {h} minutes; a cell's channels can carry {A} erlangs at 2% blocking.

::: part
answer: c*h/60
unit: Erl
tolerance: 0.5%

### How much traffic does each subscriber offer?

::: misses
- [any] Calls per hour times hours per call.
:::
:::

::: part
answer: A/(c*h/60)
unit: users
tolerance: 0.5%

### How many subscribers can the cell serve?

::: misses
- [any] Cell capacity over traffic per subscriber.
:::
:::
:::

::: check
kind: parts
given: k = 2 | 3 | 4; n = 3 | 4

## Cells are split into cells with 1/{k} of the radius, keeping the same reuse pattern; the path-loss exponent is {n}.

::: part
answer: k^2
tolerance: 0.5%

### By what factor does the capacity per unit area grow?

::: misses
- [k] Cell area scales with the radius squared.
- [any] $k^2$.
:::
:::

::: part
answer: 10*n*log(k)
unit: dB
tolerance: 0.5%

### How much can each base station's transmit power fall while keeping the same signal at the new cell edge?

::: misses
- [any] $10n\log_{10}k$.
:::
:::
:::

::: check
kind: parts
given: P = -60 | -65; d = 100 | 200; k = 4 | 10; L = 24 | 30 | 40

## A drive test measures {P} dBm at {d} m from a base station and {L} dB less at {k} times that distance.

::: part
answer: L/(10*log(k))
tolerance: 0.5%

### What path-loss exponent do the measurements show?

::: misses
- [any] $n = \Delta L/(10\log_{10}k)$.
:::
:::

::: part
answer: P - L/(10*log(k))*10*log(2*k)
unit: dBm
tolerance: 0.5%

### What would you predict at twice the farther distance?

::: misses
- [any] Extrapolate from the first point: $P - 10n\log_{10}(2k)$.
:::
:::
:::

::: check
kind: parts
given: s = 6 | 8 | 10; M = 5 | 8 | 12

## Log-normal shadowing has a standard deviation of {s} dB, and a link budget leaves {M} dB of margin at the cell edge.

::: part
answer: Q(M/s)*100
unit: %
tolerance: 0.5%

### What fraction of edge locations fall below the threshold?

::: misses
- [any] $Q(M/\sigma)$.
:::
:::

::: part
answer: 1.2816*s
unit: dB
tolerance: 0.5%

### What margin would give 90% coverage at the edge?

::: misses
- [any] $Q(x) = 0.1$ at x = 1.2816.
:::
:::
:::

::: check
kind: parts
given: r = 0.1 | 0.3 | 0.5; f = 20 | 100 | 500

## A Rayleigh-fading envelope has a {f} Hz maximum Doppler shift; consider the level {r} times its rms value.

::: part
answer: (1 - exp(-r^2))*100
unit: %
tolerance: 0.5%

### What fraction of the time is the envelope below that level?

::: misses
- [any] $1 - e^{-\rho^2}$.
:::
:::

::: part
answer: sqrt(2*pi)*f*r*exp(-r^2)
unit: Hz
tolerance: 0.5%

### How many times per second does it cross the level going up?

::: misses
- [any] $\sqrt{2\pi}f_d\rho e^{-\rho^2}$.
:::
:::

::: part
answer: (exp(r^2) - 1)/(r*f*sqrt(2*pi))*1000
unit: ms
tolerance: 0.5%

### How long does an average fade below it last?

::: misses
- [any] Fraction of time below over the crossing rate: $\frac{e^{\rho^2} - 1}{\rho f_d\sqrt{2\pi}}$.
:::
:::
:::

::: check
kind: parts
given: f = 0.9 | 2.4 | 5.8; v = 3 | 50 | 120

## A receiver moves at {v} km/h on a {f} GHz carrier.

::: part
answer: 2.405/(2*pi*v/3.6*f*1e9/299792458)*1000
unit: ms
tolerance: 0.5%

### After how long does the channel's autocorrelation $J_0(2\pi f_d\tau)$ first reach zero?

::: misses
- [any] $J_0$'s first zero is at 2.405: $\tau = 2.405/(2\pi f_d)$.
:::
:::

::: part
answer: 2.405/(2*pi)*299792458/(f*1e9)*100
unit: cm
tolerance: 0.5%

### How far has it moved by then?

::: misses
- [any] $v\tau = 0.383\lambda$.
:::
:::
:::

::: check
kind: parts
given: E = 10 | 15 | 20

## BPSK runs over Rayleigh fading at {E} dB average Eb/N0 per branch.

::: part
answer: ((1 - sqrt(10^(E/10)/(1 + 10^(E/10))))/2)^2*(2 + sqrt(10^(E/10)/(1 + 10^(E/10))))
tolerance: 1%

### What is the exact bit error rate with two-branch MRC?

::: misses
- [3*(1/(4*10^(E/10)))^2] That's the high-SNR approximation.
- [any] $\left(\frac{1 - \mu}{2}\right)^2(2 + \mu)$.
:::
:::

::: part
answer: ((1 - sqrt(10^(E/10)/2/(1 + 10^(E/10)/2)))/2)^2*(2 + sqrt(10^(E/10)/2/(1 + 10^(E/10)/2)))
tolerance: 1%

### What does Alamouti's code from two transmit antennas give at the same total power?

::: misses
- [any] Two-branch MRC at half the SNR per branch.
:::
:::
:::

::: check
kind: parts
given: R = 1 | 2 | 4; S = 10 | 20 | 30

## A Rayleigh link runs at {R} bit/s/Hz with {S} dB average SNR, and two independent branches are combined.

::: part
answer: 1 - exp(-(2^R - 1)/10^(S/10))*(1 + (2^R - 1)/10^(S/10))
tolerance: 1%

### What is its exact outage probability?

::: misses
- [1 - exp(-(2^R - 1)/10^(S/10))] That's one branch.
- [any] $1 - e^{-x}(1 + x)$, $x = (2^R - 1)/\text{SNR}$.
:::
:::

::: part
answer: ((2^R - 1)/10^(S/10))^2/2
tolerance: 2%

### What does the high-SNR approximation $x^L/L!$ give?

::: misses
- [any] $x^2/2$.
:::
:::
:::

::: check
kind: parts
given: G = 21.1 | 24.1 | 27.1; E = 5 | 7; v = 0.4 | 0.6; f = 0.5 | 0.85

## A CDMA cell has {G} dB of processing gain; users need {E} dB of Eb/N0, talk {v} of the time, and other cells add a fraction {f} of the in-cell interference.

::: part
answer: 1 + 10^(G/10)/(10^(E/10)*v*(1 + f))
unit: users
tolerance: 0.5%

### How many users fit, with perfect power control?

::: misses
- [1 + 10^(G/10)/10^(E/10)] Voice activity and other-cell interference change the count.
- [any] $1 + \frac{G_p}{(E_b/N_0)\nu(1 + f)}$.
:::
:::

::: part
answer: 3*(1 + 10^(G/10)/(10^(E/10)*v*(1 + f)))
unit: users
tolerance: 0.5%

### About how many with three ideal sectors?

::: misses
- [any] Each sector sees a third of the interference: three times the users.
:::
:::
:::

::: check
kind: choice

## Why can a CDMA network reuse every frequency in every cell, while an FDMA network typically needs a cluster of seven?

- [ ] CDMA cells are smaller
- [x] CDMA spreads each user's signal and despreads only the wanted code, so interference from neighboring cells, like in-cell users, is suppressed by the processing gain and only adds a fraction f to the noise; an FDMA receiver has no such gain and needs 18 dB or so of SIR, which only distant co-channel cells provide
- [ ] CDMA uses higher frequencies
- [ ] FDMA can't use power control

::: misses
- [1] Cell size doesn't change the ratio of interference to signal at a given reuse.
- [3] Frequency doesn't matter here.
- [4] FDMA systems do use power control; their problem is the SIR they need.
:::
:::
:::