S8 · Lesson 21 · Bandwidth efficiency and the Shannon limit
The plane of spectral efficiency against Eb/N0, Shannon's capacity bound, where real modulations sit, the gap to capacity, and the −1.6 dB floor
Every modulation scheme so far has been a point in a trade-off: bits per second per hertz on one side, energy per bit on the other. Shannon's 1948 capacity theorem draws the line that no scheme can cross. For any spectral efficiency it gives the least Eb/N0 at which error-free communication is possible at all, and below about −1.6 dB nothing works however much bandwidth is spent. Plotting QAM, PSK and orthogonal signaling against that line shows how far uncoded modulation falls short, about 8 to 10 dB at practical error rates, and that gap is exactly what error-correcting codes go after.
- Shannon's bound, the least for reliable communication at spectral efficiency η, (curve), with the uncoded requirements of common schemes at (points; Nyquist pulses, so QAM's η is ).
- QAM points sit 7.5 to 8 dB to the right of the bound; orthogonal FSK reaches low efficiencies but stays 7 dB or more from the curve there.
- Everything to the left of the curve is impossible. Modern codes (lesson 36) come within a decibel of it.
Predict
QPSK carries 2 bits/s/Hz and needs 9.6 dB for 10⁻⁵ without coding. What's the least Eb/N0 that any scheme at 2 bits/s/Hz could use?
= 1.5, or 1.76 dB. Uncoded QPSK is 7.8 dB away from that limit at 10⁻⁵. Strong error-correcting codes recover most of it: modern LDPC-coded QPSK at rate 1/2 or so works within a decibel or two of the bound for its efficiency.
Name it
Capacity
For a band-limited channel with additive white Gaussian noise,
Rates below C can be sent with arbitrarily small error probability (using long enough codes); rates above it can't.
The bound in the efficiency plane
Writing η = R/B and , operating at R = C gives
the boundary between possible (to its right) and impossible. As η → 0 (unlimited bandwidth), = −1.59 dB, the Shannon limit. At high η each extra bit/s/Hz costs about 3 dB more Eb/N0.
Where schemes sit
- Bandwidth-efficient schemes (QAM, PSK) live at η > 1, needing more Eb/N0 as η grows.
- Power-efficient schemes (orthogonal FSK) live at η < 1, needing less Eb/N0 as η falls.
- The horizontal distance from a scheme's point to the curve is its gap to capacity; uncoded modulation at 10⁻⁵ is 7 to 10 dB from it.
Equivalently, to carry η bits/s/Hz at all, a channel needs SNR ≥ .
Worked example
A 3.1 kHz telephone channel has a 30 dB SNR. What's its capacity, and how close did 33.6 kb/s modems come?
Show the solution
- Capacity.
- V.34 modems. At 33.6 kb/s they used a little more bandwidth (about 3.4 kHz), and the channel's SNR was sometimes higher; they ran within a few dB of capacity using trellis coding and adaptive equalization.
- 56k modems. Faster "56k" modems exploited the digital network's internal structure, a different channel.
Answer the capacity is 30.9 kb/s, and 33.6 kb/s modems ran within a few dB of it.
Worked example
How far is uncoded 16-QAM from the Shannon bound at its efficiency?
Show the solution
- The bound at η = 4.
- The gap. Uncoded 16-QAM needs 13.4 dB for 10⁻⁵:
- What a code could buy. A code that closes 5 dB of it would let the same link run with about a third of the transmit power.
Answer uncoded 16-QAM is 7.7 dB from the Shannon bound.
Worked example
A 20 MHz channel has an SNR of 25 dB. What is its capacity, and what is the least Eb/N0 that could use it all?
Show the solution
- Capacity.
- Efficiency.
- Least Eb/N0. Operating at capacity needs
- In practice. Real systems at this SNR use 256-QAM with strong codes and reach perhaps 6 to 7 b/s/Hz.
Answer the capacity is 166 Mb/s, and using all of it needs at least 15.8 dB of Eb/N0.
Check
What's the least Eb/N0 that allows reliable communication at 2 bits/s/Hz?
Check
An uncoded scheme at 2 bits/s/Hz needs 13.43 dB for 10⁻⁵. How far is it from the Shannon bound?
Check
A 20 kHz channel has an SNR of 6 dB. What's its capacity?
Write units the way you normally would: 1.5 kb/s, 1500 b/s and 0.0015 Mb/s are the same answer.
Check
What SNR does a channel need, at minimum, to carry 2 bits/s/Hz?
Check
A channel's SNR is 15 dB. What's the most bits per second per hertz it can carry?
Check
A code closes 6 dB of a link's gap to capacity. What fraction of the original transmit power does the same link now need?
Check
A 20 MHz channel has an SNR of 5 dB.
(a)
What is its capacity?
Write units the way you normally would: 1.5 Mb/s, 1500 kb/s and 0.0015 Gb/s are the same answer.
(b)
What is the least Eb/N0 that could reach it?
Check
A channel has bandwidth B and SNR S (linear); a scheme runs at efficiency n.
Step 1
What is its capacity?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What least Eb/N0 does efficiency n need?
Step 3
What least SNR?
Explain why
Why is there a minimum Eb/N0 even with unlimited bandwidth?
Spreading a fixed signal power over more bandwidth lets each hertz carry very few bits, and in that limit capacity grows only in proportion to the signal power divided by the noise density, approaching bits per second however wide the band gets, because the noise collected grows as fast as the room the signal gains. Rewriting the rate in terms of energy per bit, reliable communication needs of at least ln 2, about −1.6 dB. Below that, each bit simply doesn't carry enough energy to stand out from the noise in any coding scheme, so the error probability can't be driven to zero no matter how cleverly the bandwidth is used.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.