title: Higher-order systems, zeros and dominant poles
heading: Step responses as sums of modes, when a far pole can be ignored, how a left-half-plane zero adds overshoot and a right-half-plane zero makes the response start the wrong way, and the slow tails of pole–zero dipoles
eyebrow: S9 · Lesson 8 · Higher-order systems, zeros and dominant poles
xp: 50
---

::: hook
Real closed loops have more than two poles, and they have zeros too. Yet the second-order formulas from lesson 7 are used everywhere, because in a well-designed loop one pair of poles usually dominates and the rest add only small, fast corrections. This lesson shows when that's true, and it shows the two cases where it fails: a zero near the dominant poles, which can double the overshoot, and a zero in the right half-plane, which makes the response start off in the wrong direction.
:::

::: play
- The step response of $(1 + as)\cdot\frac{1}{s^2 + s + 1}$ (ζ = 0.5, $\omega_n$ = 1), which is the original response plus a times its derivative.
- a > 0 puts a zero at −1/a in the left half-plane: the derivative term adds a kick, and overshoot rises (30% for a zero at −1).
- a < 0 puts the zero in the right half-plane at +1/|a|: the response first dips below zero before rising, because the derivative term starts out pulling the wrong way.
:::

```sim plot
view: graph
x: t = 0..12 s
y: y = -0.5..1.8
slider: a = -1..2 = 0.5
plot: 1 - exp(-0.5*t)*(cos(sqrt(0.75)*t) + 0.5/sqrt(0.75)*sin(sqrt(0.75)*t)) + a*exp(-0.5*t)*sin(sqrt(0.75)*t)/sqrt(0.75) | samples: 600 | label: with the zero
plot: 1 - exp(-0.5*t)*(cos(sqrt(0.75)*t) + 0.5/sqrt(0.75)*sin(sqrt(0.75)*t)) | dashed | color: ch3 | label: without it
```

::: predict
## A third pole at −5 is added to a loop whose dominant poles are $-0.5 \pm j0.866$ (ζ = 0.5). What happens to the 16.3% overshoot?

- [ ] It doubles
- [x] It falls slightly, to about 16%
- [ ] It disappears
- [ ] The loop goes unstable

::: reveal
A pole ten times farther from the imaginary axis than the dominant pair contributes a small, fast term: its residue in the step response is $1/(25 - 5 + 1)$ = 0.048 and it dies out in about a second. Simulated, the overshoot becomes 15.9% and the peak comes 0.2 s later. Move the pole in to −1 and the overshoot halves to 8.1%: then it's no longer far.
:::
:::

::: nameit
## Modes

A step response is a sum of terms, one per pole: $y(t) = T(0) + \sum_k r_ke^{p_kt}$, with residues $r_k$ from partial fractions. A pole's influence depends on its residue (how big its term starts) and its real part (how fast it dies).

## Dominant poles

Poles much farther left than the dominant ones, five times or more, have small residues and die out fast. For a third pole at −p added to the standard second-order system (scaled to keep T(0) = 1), the step residue is $-\omega_n^2/(p^2 - 2\zeta\omega_np + \omega_n^2)$. Simulated overshoots with ζ = 0.5, $\omega_n$ = 1:

| Extra pole at | none | −10 | −5 | −2 | −1 |
|---|---|---|---|---|---|
| Overshoot | 16.3% | 16.2% | 15.9% | 13.9% | 8.1% |

## Zeros

A zero at −z multiplies the response by $(1 + s/z)$, adding $1/z$ times its derivative. Close zeros matter a lot:

| Zero at | −5 | −2 | −1 | −0.5 |
|---|---|---|---|---|
| Overshoot | 16.7% | 19.1% | 29.8% | 69.9% |

A **right-half-plane zero**, $(1 - s/z)$, subtracts the derivative, so the response starts by moving the wrong way: with a zero at +1 the example dips to −0.28. Plants with RHP zeros are **nonminimum phase**; a boost converter's control-to-output response and an aircraft's altitude response to the elevator both have one, and they limit how fast a loop can be (lesson 28).

## Dipoles

A pole and zero close together barely change the fast response but leave a slow tail of amplitude about $|1 - p/z|$, decaying with the pole. A lag compensator (lesson 14) creates exactly this.
:::

::: example
## What does a right-half-plane zero do to a first-order plant? Take $T = (1 - s/z)/(\tau s + 1)$.

::: solution
1. **Just after the step.**
   $$\begin{aligned} y(0^+) &= T(\infty) \\ &= -\frac{1}{z\tau} \end{aligned}$$
   The output jumps the wrong way.
2. **The rest of the response.** It then rises to 1:
   $$y(t) = 1 - \left(1 + \frac{1}{z\tau}\right)e^{-t/\tau}$$
3. **Put in numbers.** With τ = 1 s and a zero at +2, the output starts at
   $$\begin{aligned} y(0^+) &= -\frac{1}{2 \times 1} \\ &= -0.5 \end{aligned}$$
4. **Speed costs more undershoot.** The faster you try to make such a system respond, the bigger the wrong-way excursion.

**Answer:** it makes the output start the wrong way, at $-1/(z\tau)$, before rising to 1; with τ = 1 s and a zero at +2 it starts at −0.5.
:::
:::

::: example
## A loop's slow pole at −1 sits next to a zero at −1.1, with the rest of the loop $10/(s + 10)$. What does the tail look like?

::: solution
1. **Residue of the slow pole.** The step residue at −1 is
   $$\begin{aligned} r &= -(1 - p/z)\,G(-p) \\ &= -(1 - \tfrac{1}{1.1}) \times \tfrac{10}{9} \\ &= -0.101 \end{aligned}$$
2. **Shape of the tail.** The output reaches about 90% quickly, then creeps the last 10% with a 1 s time constant:
   $$\begin{aligned} y(1\ \text{s}) &= 0.963 \\ y(3\ \text{s}) &= 0.995 \end{aligned}$$
3. **Settling time.** Getting within 2% takes about
   $$\begin{aligned} t_s &\approx \ln(0.101/0.02) \\ &= 1.6\ \text{s} \end{aligned}$$
   even though the fast part settles in a fraction of that.

**Answer:** a quick rise to about 90%, then a slow creep with a 1 s time constant (0.963 at 1 s, 0.995 at 3 s), settling within 2% after about 1.6 s.
:::
:::

::: example
## A PI controller's zero cancels the plant pole of $1/(10s + 1)$, giving L = 1/s and a fast, clean step response. What does a step disturbance at the plant's input do?

::: solution
1. **What the reference sees.**
   $$T = \frac{1}{s + 1}$$
2. **What the disturbance sees.** It reaches the output through
   $$PS = \frac{1}{10s + 1}\cdot\frac{s}{s + 1}$$
3. **Its step response.**
   $$y_d(t) = \frac{0.1}{0.9}\left(e^{-0.1t} - e^{-t}\right)$$
4. **Peak and tail.** It peaks at
   $$\begin{aligned} t &= \ln 10/0.9 \\ &= 2.56\ \text{s} \end{aligned}$$
   at 0.077, and is still 0.015 at 20 s.
5. **Why it's slow.** The cancelled pole at −0.1 is hidden from the reference but not from the disturbance, so cancelling a slow plant pole makes disturbance rejection as slow as the plant.

**Answer:** the disturbance's effect peaks at 0.077 after 2.56 s and is still 0.015 at 20 s, as slow as the cancelled plant pole.
:::
:::

::: check
given: w = 1 | 2; z = 0.3 | 0.6; p = 4 | 10
answer: w^2/(p^2 - 2*z*w*p + w^2)
tolerance: 0.5%

## A third pole at −{p} is added to $\omega_n^2/(s^2 + 2\zeta\omega_ns + \omega_n^2)$ with $\omega_n$ = {w} and ζ = {z}, keeping the DC gain at 1. How big is its term in the step response?

::: right
Right. $|r| = \omega_n^2/(p^2 - 2\zeta\omega_np + \omega_n^2)$ = {answer}.
:::

::: misses
- [w^2/p^2] Evaluate the quadratic at s = −p exactly.
- [any] Not yet. Find the residue of $T(s)/s$ at −p.
:::
:::

::: check
given: t = 0.5 | 2; z = 1 | 4 | 10
answer: 1/(z*t)
tolerance: 0.5%

## A plant $T = (1 - s/z)/(\tau s + 1)$ has τ = {t} s and a zero at +{z}. How far below zero does its step response start?

::: right
Right. $y(0^+) = T(\infty) = -1/(z\tau)$: a dip of {answer}.
:::

::: misses
- [1/z] Divide by τ too: $T(\infty) = (-1/z)/\tau$.
- [any] Not yet. Use the initial value theorem.
:::
:::

::: check
given: t = 0.2 | 1 | 5; z = 0.5 | 3
answer: 1/(z*t)
tolerance: 0.5%

## A system $(1 + s/z)/(\tau s + 1)$ has τ = {t} s and a zero at −{z}. To what value does its step response jump at t = 0⁺?

::: right
Right. $T(\infty) = 1/(z\tau)$ = {answer}; it then moves toward 1 with time constant τ.
:::

::: misses
- [1] That's the final value. The zero makes the response jump at once.
- [any] Not yet. Initial value theorem.
:::
:::

::: check
given: p = 0.5 | 1 | 2; d = 1.05 | 1.2; c = 10 | 20
answer: (1 - 1/d)*c/(c - p)
tolerance: 0.5%

## A slow pole at −{p} and a zero at −{d}×{p} sit in a loop whose fast part is $\given{c}/(s + \given{c})$. How big is the slow tail in the step response?

::: right
Right. $(1 - p/z)\,G(-p)$ = {answer}, decaying at the slow pole's rate.
:::

::: misses
- [1 - 1/d] That leaves out the fast part's gain at s = −p, $c/(c - p)$.
- [any] Not yet. Residue of $T(s)/s$ at the slow pole.
:::
:::

::: check
given: a = 1 | 3; b = 4 | 10; t = 0.5 | 1
answer: 1 - (b*exp(-a*t) - a*exp(-b*t))/(b - a)
tolerance: 0.5%

## $T = ab/((s + a)(s + b))$ with a = {a} and b = {b}. What's its step response at t = {t} s?

::: right
Right. $1 - \frac{be^{-at} - ae^{-bt}}{b - a}$ = {answer}.
:::

::: misses
- [1 - exp(-a*t)] That keeps only the slow pole; the fast one still matters this early.
- [any] Not yet. Partial fractions of $T(s)/s$.
:::
:::

::: check
given: K = 5 | 20; z = 1 | 3; a = 2 | 5; b = 4 | 8
answer: K*z/(a*b*10)
tolerance: 0.5%

## $T(s) = \given{K}(s + \given{z})/((s + \given{a})(s + \given{b})(s + 10))$. Where does its step response settle?

::: right
Right. $T(0) = Kz/(10ab)$ = {answer}.
:::

::: misses
- [any] Not yet. Set s = 0.
:::
:::

::: check
kind: parts
given: t = 5 | 10 | 30; c = 0.5 | 1 | 2

## A PI zero cancels the plant pole of $1/(\tau s + 1)$ with τ = {t} s, and the loop is $L = 1/(\tau_cs)$ with $\tau_c$ = {c} s. A unit step disturbance enters at the plant's input.

::: part
answer: ln(t/c)/(1/c - 1/t)
unit: s
tolerance: 0.5%

### When does its effect on the output peak?

::: misses
- [any] $y = \frac{1/\tau}{1/\tau_c - 1/\tau}(e^{-t/\tau} - e^{-t/\tau_c})$ peaks where its derivative is zero.
:::
:::

::: part
answer: (1/t)/(1/c - 1/t)*(exp(-ln(t/c)/(1/c - 1/t)/t) - exp(-ln(t/c)/(1/c - 1/t)/c))
tolerance: 0.5%

### How large is the peak?

::: misses
- [any] Evaluate $y(t^*)$.
:::
:::
:::

::: check
kind: derivation
vars: a = 0.1..10, b = 11..100

## The closed loop $T = ab/((s + a)(s + b))$ gets a unit step.

::: step
answer: -b/(b - a)

### What is the coefficient of $e^{-at}$ in the response?
:::

::: step
answer: a/(b - a)

### And of $e^{-bt}$?
:::

::: right
Right. The slow pole's residue is close to −1 and the fast one's is small: the slow pole dominates.
:::
:::

::: explain
## Why does a right-half-plane zero make a step response start in the wrong direction?

::: model
A zero at +z multiplies the transfer function by $1 - s/z$, so the output is the response without the zero minus $1/z$ times its derivative. Right after a step, the response without the zero is still near zero but already rising, so its derivative is large and positive while its value is tiny, and subtracting the derivative drives the output negative. Only later, once the rise slows, does the value term win and the output head toward its final value. A boost converter shows this: asking for more output voltage means first holding the switch on longer, which briefly starves the output of current before the inductor's extra energy arrives.
:::
:::

::: practice

::: check
given: t = 0.3 | 3; z = 2 | 6
answer: 1/(z*t)
tolerance: 0.5%

## Initial dip of $(1 - s/z)/(\tau s + 1)$ with τ = {t} s, zero at +{z}?

::: misses
- [any] $1/(z\tau)$.
:::
:::

::: check
given: w = 1 | 3; z = 0.4 | 0.7; p = 6 | 15
answer: w^2/(p^2 - 2*z*w*p + w^2)
tolerance: 0.5%

## Residue of a third pole at −{p} ($\omega_n$ = {w}, ζ = {z})?

::: misses
- [any] $\omega_n^2/(p^2 - 2\zeta\omega_np + \omega_n^2)$.
:::
:::

::: check
given: a = 0.5 | 2; b = 6 | 12; t = 0.4 | 2
answer: 1 - (b*exp(-a*t) - a*exp(-b*t))/(b - a)
tolerance: 0.5%

## Step response of $ab/((s + a)(s + b))$ at t = {t} s, a = {a}, b = {b}?

::: misses
- [any] Partial fractions.
:::
:::
:::