S9 Feedback control · Practice
Every topic, mixed
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Topics: all 51
Check
An amplifier has open-loop gain 1000 and feedback fraction β = 0.01. What's its closed-loop gain?
Check
An amplifier's open-loop gain falls 50% from 10000, with β = 0.01. By what percentage does the closed-loop gain fall?
Check
A load step would slow a motor by 12 rpm without control. With a loop gain of 4, how much does it slow?
Check
A proportional controller with = 5 drives a plant with DC gain 0.4. What percentage of a step reference is left as steady error?
Check
A loop has very high gain, but its sensor reads 2% high. By what percentage does the output end up low?
Check
An amplifier must have a closed-loop gain within 0.5% of with β = 0.01. What's the least open-loop gain A that does it?
Check
A loop gain of 50 acts on a disturbance that would move the output 0.5 mm, and on 0.02 mm of sensor noise at the same frequency.
(a)
How much of the disturbance remains?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
(b)
How much sensor noise reaches the output?
Check
Closed-loop gain with A = 500, β = 0.02?
Check
A disturbance of 8 °C open loop, loop gain 3: what's left?
Check
Steady error under = 8 with plant DC gain 0.2?
Check
A motor with = 0.02, R = 4 Ω and friction b = 0.0005 N·m·s runs on 12 V with no load. What's its steady speed?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A motor has rotor inertia 1 × 10⁻⁵ kg·m², = 0.02, R = 4 Ω and b = 0.0005. What's its mechanical time constant?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
A 0.5 kg mass on a 200 N/m spring has damping 20 N·s/m. What's its damping ratio?
Check
What's the undamped natural frequency of a 2 kg mass on a 200 N/m spring?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
Check
A heated block has thermal resistance 2 K/W to ambient and heat capacity 200 J/K, and is driven with 5 W. What's its time constant?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A series RLC circuit has R = 20 Ω, L = 1 mH and C = 1 µF. What's its damping ratio?
Check
A motor of inertia 1 × 10⁻⁵ kg·m² drives a load of 0.0002 kg·m² through a 20:1 gearbox.
(a)
What total inertia does the motor see?
Write units the way you normally would: 1.5 kg*m^2 and 1500 g*m^2 are the same answer.
(b)
What ratio would give the load its fastest acceleration for a given motor torque?
Check
No-load speed: 9 V, K = 0.03, R = 3 Ω, b = 0.001?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
Damping ratio: m = 0.2 kg, k = 100 N/m, b = 30 N·s/m?
Check
Series RLC damping ratio: R = 10 Ω, L = 2 mH, C = 2 µF?
Check
What's the small-swing period of a pendulum 1 m long?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A pendulum 0.5 m long is balanced upright. How long does a small tilt take to double?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
A maglev rig holds its ball 5 mm from the magnet. Where's its unstable pole?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A tank of area 1 m² holds 0.5 m with a steady flow of 0.02 m³/s through a valve. What's its linearized time constant?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
At 15°, how far (as a percentage) does θ overstate sin θ?
Check
A diode with ideality factor 1.2 is biased at 0.1 mA at 300 K. What's its small-signal resistance?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A magnetic levitation rig holds its ball 10 mm from the magnet with 0.5 A of coil current.
(a)
Where is its unstable pole?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
How strongly does a current change accelerate the ball, in m/s² per ampere?
Check
Small-swing period of a 0.8 m pendulum?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
Maglev unstable pole at an 8 mm gap?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
Tank time constant: area 0.5 m², level 1 m, flow 0.05 m³/s?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A plant with τ = 50 ms gets proportional control = 5. What's the closed-loop time constant?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
What's the DC gain of the closed loop around with = 1?
Check
An inner loop = 4 with feedback = 1 sits inside an outer loop: = 2, feedback = 0.5. What's the overall DC gain?
Check
A loop gain with K = 4 and a = 4. What's the closed loop's damping ratio?
Check
A disturbance of 1 units enters at the input of a plant with DC gain 4, under proportional control = 3. How much does it change the output at DC?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A forward gain G = 100 has a sensor gain H = 0.1 in its feedback path. What's the closed-loop gain?
Check
A plant of DC gain 2 is under proportional control = 1 with unity feedback.
(a)
What is the closed-loop DC gain from reference to output?
(b)
What DC gain does a disturbance at the plant's input see?
(c)
And sensor noise (in magnitude)?
Check
Closed-loop time constant: τ = 5 ms, = 1, = 4?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
Damping ratio for ?
Check
Nested loops: = 3, = 2, = 2, = 1. DC gain?
Check
An amplifier with open-loop gain 2000 and β = 0.01.
(a)
Closed-loop gain?
(b)
Percentage drop in closed-loop gain if A falls 60%?
(c)
Least A for a gain within 1% of 1/β?
Check
A loop with gain 19 at low frequencies; separately, = 10 on a plant of DC gain 3.
(a)
What's left of a 6 °C output disturbance?
(b)
Steady error to a step, as a percentage?
Check
A DC motor: 12 V, = 0.03, R = 2.5 Ω, b = 0.0004 N·m·s, J = 2 × 10⁻⁵ kg·m².
(a)
No-load speed?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
Mechanical time constant?
(c)
Stall torque?
Check
A motor with J = 2 × 10⁻⁵ kg·m², L = 0.2 mH, R = 3 Ω, = 0.06 and b = 10⁻⁵ N·m·s. Find the exact poles of .
(a)
The slow time constant?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
(b)
The fast time constant?
Check
A 0.5 kg mass, a 300 N/m spring and a 15 N·s/m damper.
(a)
Undamped natural frequency?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
Damping ratio?
(c)
Frequency it rings at after a tap?
Check
A series RLC circuit: R = 10 Ω, L = 1 mH, C = 1 µF.
(a)
Natural frequency?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
Damping ratio?
Check
A pendulum 0.6 m long.
(a)
Small-swing period hanging down?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(b)
Doubling time of a small tilt when balanced upright?
Check
A maglev rig holds its ball at a 4 mm gap with 0.4 A.
(a)
Unstable pole?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
Acceleration per ampere of current change?
Check
A tank of area 0.3 m² holds 0.8 m with a steady flow of 0.03 m³/s.
(a)
Outflow change per meter of level change?
(b)
Time constant?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
with τ = 20 ms under = 3; a disturbance of 2 units at the plant's input.
(a)
Closed-loop time constant?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
(b)
Closed-loop DC gain?
(c)
DC change in output from the disturbance?
Check
Nested loops ( = 4, = 3, = 0.6, = 0.3); and a loop .
(a)
Nested loops' DC gain?
(b)
Second loop's damping ratio?
Check
A block with thermal resistance 1.5 K/W and heat capacity 400 J/K is heated with 4 W.
(a)
Final rise above ambient?
Write units the way you normally would: 1.5 K and 1500 mK are the same answer.
(b)
Time to reach 90% of it?
Check
A loop with gain 100 has a plant whose gain falls 5%, and a sensor that reads 3% high.
(a)
By about how much does the closed-loop gain fall because of the plant?
(b)
By how much does the output end up low because of the sensor?
Check
A heat sink radiates with emissivity 0.8 from 0.005 m² at 500 K to cooler surroundings.
(a)
What incremental conductance does radiation give it?
Write units the way you normally would: 1.5 W/K, 1500 mW/K and 0.0015 kW/K are the same answer.
(b)
What thermal resistance is that?
Check
A plant P = 2 has feedback controller C = 2 and a feedforward F = 0.5 from the reference to the plant's input.
(a)
What is the closed-loop gain?
(b)
What F would make it exactly 1?
Check
A step of 5 in the input changes the output by 10 in the end; it reaches 28.3% of that change 6 s after the step and 63.2% 1.5 s after the 28.3% point.
(a)
What time constant does the two-point method give?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(b)
What dead time?
(c)
What gain?
Check
A least-squares fit of sampled data gives with a sample period of 100 ms.
(a)
What time constant does that describe?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
(b)
What DC gain?
Check
A sine test on a first-order plant at 2 Hz measures a phase of −30° and a gain of 4.
(a)
What is τ?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(b)
What is K?
Check
A step test overshoots by 20% and rings with a period of 0.1 s.
(a)
What damping ratio does a second-order fit give?
(b)
What natural frequency?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A plant is reduced to FOPDT by the half rule.
(a)
What time constant results?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(b)
What dead time?
Check
A gain is estimated by least squares from 100 samples of an input with mean square 4, with output noise σ = 0.05.
(a)
What is the estimate's standard deviation?
(b)
How many samples would bring it to 0.003?
Check
Two-point τ when the 63.2% point comes 2 s after the 28.3% point?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
τ from a discrete pole 0.7 at T = 5 ms?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
τ from −30° at 1 Hz?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A second-order system has ζ = 0.4. What's its step overshoot?
Check
What damping ratio gives 5% overshoot?
Check
A system with = 10 rad/s and ζ = 0.3. When does its step response peak?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
Estimate the 2% settling time for = 20 rad/s and ζ = 0.3.
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A first-order system has a time constant of 3 ms. What's its 10–90% rise time?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
A pair of poles sits at . What's their damping ratio?
Check
A step response overshoots by 15% and peaks at 0.05 s.
(a)
What is ζ?
(b)
What is ?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
Overshoot for ζ = 0.35?
Check
Damping ratio for 8% overshoot?
Check
Peak time for = 3, ζ = 0.4?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A third pole at −10 is added to with = 1 and ζ = 0.3, keeping the DC gain at 1. How big is its term in the step response?
Check
A plant has τ = 0.5 s and a zero at +1. How far below zero does its step response start?
Check
A system has τ = 1 s and a zero at −0.5. To what value does its step response jump at t = 0⁺?
Check
A slow pole at −1 and a zero at −1.05×1 sit in a loop whose fast part is . How big is the slow tail in the step response?
Check
with a = 1 and b = 4. What's its step response at t = 1 s?
Check
. Where does its step response settle?
Check
A PI zero cancels the plant pole of with τ = 10 s, and the loop is with = 0.5 s. A unit step disturbance enters at the plant's input.
(a)
When does its effect on the output peak?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(b)
How large is the peak?
Check
Initial dip of with τ = 0.3 s, zero at +2?
Check
Residue of a third pole at −15 ( = 1, ζ = 0.4)?
Check
Step response of at t = 2 s, a = 0.5, b = 6?
Check
A loop . What's the largest K for which it's stable?
Check
At its stability limit, oscillates. At what frequency?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A loop . What's the largest stable K?
Check
How many roots of lie in the right half-plane?
Check
What's the first-column entry in the row of the Routh array for ?
Check
At its stability limit, oscillates. At what frequency?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A loop has , with one unstable plant pole.
(a)
Above what gain is it stable?
(b)
At what frequency does it oscillate at that gain?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
Critical gain of ?
Check
Critical gain of ?
Check
Oscillation frequency at the limit for ?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A servo with follows a reference rising at 2 rad/s. What's its steady lag?
Write units the way you normally would: 1.5 rad and 1500 mrad are the same answer.
Check
A type-0 loop . What percentage of a step reference is left as error?
Check
A type-2 loop follows . What's its steady error?
Check
A loop must follow a unit ramp with error at most 0.01. What's the least K?
Check
PI control with = 0.5 and = 0.5 s drives a plant with DC gain 4. What's the steady error to a ramp of slope 3?
Check
A closed loop has . What percentage of a step is left as error?
Check
A servo loop with K = 40 and a = 2: the gain K sits in the controller, and the plant is .
(a)
What lag remains when the reference ramps at 2 units/s?
(b)
What steady error does a constant disturbance of 1 at the plant's input leave?
Check
Ramp lag of at 5 rad/s?
Write units the way you normally would: 1.5 rad and 1500 mrad are the same answer.
Check
Step error of ?
Check
Least K for unit-ramp error 0.002 with ?
Check
A second-order system with = 12 rad/s and ζ = 0.25.
(a)
Overshoot?
(b)
Peak time?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(c)
Settling estimate?
Check
A loop must overshoot at most 4% and settle within 0.2 s.
(a)
Least damping ratio?
(b)
Least real part σ of the dominant poles?
(c)
at the corner where both limits meet?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
Dominant poles at .
(a)
Damping ratio?
(b)
Natural frequency?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(c)
Overshoot?
Check
A first-order system with τ = 7 ms.
(a)
10–90% rise time?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
(b)
Time to stay within 2%?
Check
A third pole at added to a second-order system with ζ = 0.3, keeping the DC gain at 1; and with a = 2, b = 15.
(a)
Size of the third pole's step-response term?
(b)
Second system's step response at t = 0.3 s?
Check
A plant with τ = 0.5 s and a zero at +0.5.
(a)
Depth of the initial dip?
(b)
When does the response cross zero?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A slow pole at −0.5 with a zero 1.1 times as far from the origin, inside a loop whose fast part is .
(a)
Amplitude of the slow tail?
(b)
When does the tail fall within 2%?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
.
(a)
Critical gain?
(b)
Oscillation frequency there?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
.
(a)
Critical gain?
(b)
Oscillation frequency?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(c)
Gain margin of K = abc (DC loop gain 1), as a factor?
Check
The polynomial .
(a)
First-column entry of the row?
(b)
Right-half-plane roots?
Check
A servo following 3 rad/s; and a type-0 loop .
(a)
Servo's steady lag?
Write units the way you normally would: 1.5 rad and 1500 mrad are the same answer.
(b)
Servo's damping ratio?
(c)
Type-0 loop's step error?
Check
PI control ( = 1, = 1 s) on a plant of DC gain 2; and .
(a)
PI loop's ?
(b)
Second loop's ?
Check
A servo must follow a unit ramp within 0.01.
(a)
Least K?
(b)
Overshoot at that K?
Check
A loop's characteristic polynomial is .
(a)
Below what K is it stable?
(b)
At what frequency does it oscillate at that limit?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A PI zero cancels the plant pole of , τ = 10 s, leaving with = 0.5 s. A unit step disturbance enters at the plant's input.
(a)
When does the output's deviation peak?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(b)
What deviation remains at ?
Check
: where do its asymptotes meet?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A loop gain has 4 poles and 1 zeros. At what angle from the positive real axis is its first asymptote?
Check
Where does the locus of break away from the real axis?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
What's the gain at the breakaway point of ?
Check
A loop . At what angle does the locus leave the upper pole?
Check
For , what gain puts the closed-loop poles at ?
Check
A loop has two poles and a zero further left, so its complex branches form a circle.
(a)
Where do the branches break away from the real axis?
(b)
Where do they break back in?
(c)
What is the circle's radius, centered on the zero?
Check
Centroid for ?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
Breakaway point of ?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
Gain for poles at with ?
Check
A lead compensator has its zero at −3 and pole at −12. How much phase does it add at ?
Check
The plant should have closed-loop poles at . How much phase must a lead compensator add there?
Check
A lead must add 20° at , with its zero at −2. Where does its pole go?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
. What K puts a closed-loop pole at , assuming the angle condition holds there?
Check
A loop has = 5 s⁻¹. A lag compensator with its zero at −0.05 and pole at −0.02 (unity gain at high frequency) is added. What's the new ?
Check
A lag with its zero at −0.1 and pole at −0.01: what phase does it add at the dominant pole ?
Check
A lead's zero cancels the pole at −2 of , and the closed-loop poles must sit at .
(a)
Where does the lead's pole go?
(b)
What gain ?
(c)
What velocity constant results, in s⁻¹?
Check
Lead angle at with zero −2.5, pole −15?
Check
Lead pole for 30° at , zero at −1?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
New after a lag (zero −0.02, pole −0.01) on = 1.5?
Check
A PID has = 2 and = 0.05 s. What's its integral gain ?
Check
A plant with τ = 50 ms gets PI control with = τ. What gives a closed-loop time constant of 5 ms?
Check
PI control with = τ = 100 ms and = 1 on a plant with DC gain 4. What's the closed-loop time constant?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
A PID has = 2 s and = 0.05 s. Where is its zero nearer the origin?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A derivative term has = 0.1 s and N = 5. Where's the filter pole?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A PI controller ( = 1, = 0.2 s) is saturated for 8 s with an error of 10 that it can't act on. Without anti-windup, how much does its integral term grow?
Check
A PID with = 2 and = 0.05 s has a derivative filter with N = 20, and its derivative acts on the error. The setpoint steps by 1.
(a)
How big is the derivative term's initial kick?
(b)
With what time constant does it decay?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
for = 0.2, = 0.02 s?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
for a 4 ms closed loop on , τ = 5 ms, = τ?
Check
Slower PID zero for = 0.5, = 0.02?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
An ultimate-gain test finds = 8 and = 0.5 s. What integral gain does the Ziegler–Nichols PID rule give?
Check
A relay of amplitude ±5 drives a loop into oscillation with amplitude 0.1 at the plant output. Estimate the ultimate gain.
Check
An FOPDT plant has K = 2, τ = 5 s and θ = 4 s. What SIMC proportional gain goes with = 3θ?
Check
For the same SIMC rule, a plant with τ = 10 s and θ = 0.5 s, and = 2θ: what integral time?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A step test gives K = 0.5, τ = 2 s and θ = 2 s. What does the Ziegler–Nichols step-response PID rule give?
Check
A plant with τ = 1 s is put under proportional control and the gain raised until it oscillates. What's the period?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A step test gives K = 2, τ = 5 s and θ = 3 s. Tune a Ziegler–Nichols PID from the step-response rules.
(a)
What integral gain results?
(b)
What derivative gain ?
Check
Ziegler–Nichols PID from = 3, = 1 s?
Check
Ultimate gain from a ±2 relay and output amplitude 0.3?
Check
SIMC with : K = 1, τ = 8 s, θ = 3 s?
Check
The locus of .
(a)
Asymptote centroid?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
Breakaway point?
(c)
Gain where it crosses the imaginary axis?
Check
A loop gain with 4 poles and 1 zeros, whose poles add up to −6·4 and zeros to −3·1.
(a)
Angle of the first asymptote?
(b)
Centroid?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A loop ; and .
(a)
Departure angle from the upper pole of the first loop?
(b)
Gain putting the second loop's poles at ?
Check
Lead design for with target poles at and the lead zero at −3.
(a)
Angle deficiency?
(b)
Lead pole?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
at the point .
(a)
Phase the compensator adds there?
(b)
K from the magnitude condition?
(c)
with that K?
Check
A lag with zero −0.05 and pole −0.025 is added to a loop with = 3, dominant poles near .
(a)
New ?
(b)
Phase it adds at the dominant pole?
Check
A PID with = 0.8, = 0.1 s, = 0.05 s and derivative filter N = 15.
(a)
?
(b)
?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(c)
Derivative filter pole?
Check
PI control with = τ on , τ = 8 ms, for a 4 ms closed-loop time constant.
(a)
?
(b)
?
Check
A PID with = 0.8 s, = 0.04 s and = 6, saturated for 2 s with error 8.
(a)
Slower zero?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
Faster zero?
(c)
Integral growth during saturation?
Check
An ultimate-gain test: = 4, = 2 s. Ziegler–Nichols PID settings:
(a)
?
(b)
?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(c)
?
Check
A relay test with amplitude ±2 gives oscillation of amplitude 0.4 and period 6 s.
(a)
Ultimate gain?
(b)
Ziegler–Nichols PI ?
(c)
Its ?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
An FOPDT plant: K = 0.4, τ = 4 s, θ = 2.5 s, SIMC with = 2θ.
(a)
?
(b)
?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(c)
For comparison, the Ziegler–Nichols step-response PID ?
Check
A plant with τ = 0.5 s, under proportional control.
(a)
Ultimate gain?
(b)
Ultimate period?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A loop has a complex pole pair and a real pole.
(a)
At what angle does the locus leave the upper complex pole?
Check
A step test gives K = 0.5, τ = 10 s and θ = 5 s. Tune a Ziegler–Nichols PI from the step-response rules.
(a)
What ?
(b)
What ?
Check
An amplifier with open-loop gain 3000 and β = 0.02.
(a)
Closed-loop gain?
(b)
Percentage drop if A falls 50%?
Check
A DC motor (12 V, = 0.04, R = 3 Ω, b = 0.0006, J = 3 × 10⁻⁵ kg·m²) under proportional speed control = 0.5 V per rad/s.
(a)
Open-loop no-load speed?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
Mechanical time constant?
(c)
Closed-loop time constant?
Check
A maglev rig at a 3 mm gap; a pendulum 0.4 m long balanced upright.
(a)
Maglev's unstable pole?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
Pendulum's doubling time?
Check
A second-order loop with = 5 rad/s and ζ = 0.3.
(a)
Overshoot?
(b)
Peak time?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(c)
Settling estimate?
Check
Specifications: at most 6% overshoot, 2% settling within 0.4 s.
(a)
Least ζ?
(b)
at the corner of the region?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A plant with τ = 0.4 s and a zero at +1.
(a)
Initial dip?
(b)
Zero-crossing time?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
.
(a)
Critical gain?
(b)
Oscillation frequency?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
The polynomial .
(a)
First-column entry of the row?
(b)
Right-half-plane roots?
Check
A servo tracking 2 rad/s; a loop .
(a)
Servo's ramp lag?
Write units the way you normally would: 1.5 rad and 1500 mrad are the same answer.
(b)
Second loop's step error?
Check
The locus of .
(a)
Centroid?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
Breakaway point?
(c)
Gain there?
Check
A lead for , targeting with its zero at −3.
(a)
Angle deficiency?
(b)
Lead pole?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A lag (zero −0.04, pole −0.02) on a loop with = 1.5 and dominant poles near .
(a)
New ?
(b)
Phase it adds at the dominant pole?
Check
PI control with = τ on , τ = 6 ms, for a 3 ms closed loop.
(a)
?
(b)
?
Check
A relay test (±3) gives oscillation amplitude 0.5 and period 7 s. Ziegler–Nichols PID:
(a)
?
(b)
?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(c)
?
Check
An FOPDT plant (K = 0.6, τ = 6 s, θ = 3 s), SIMC with = θ.
(a)
?
(b)
?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A step test's output reaches 28.3% of its change 5 s after the step and 63.2% 1 s after that; its gain is 3.
(a)
What τ does the two-point fit give?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(b)
What SIMC goes with = θ?
Check
A motor with J = 0.0001 kg·m², viscous friction b = 0.001 N·m·s and = 0.03 N·m/A follows a trajectory accelerating at 200 rad/s² while turning at 300 rad/s.
(a)
What feedforward current does it need at that moment?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What fraction of it goes to acceleration?
Check
A process gains 2 units per unit of input and 0.3 units per unit of a measured disturbance; a static feedforward is designed with a model gain for the input that's off by 20%.
(a)
What feedforward gain does the model give?
(b)
How much disturbance reaches the output per unit, before feedback?
Check
A PI controller ( = 3, = 4) runs around the plant .
(a)
Where is the closed loop's zero?
(b)
What is the closed-loop damping ratio?
(c)
What time constant must a first-order prefilter have to cancel the zero?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A PI zero cancels the plant pole of , τ = 10 s, for a loop with = 0.5 s; a feedforward cancels a fraction 0.95 of a unit step disturbance at the plant's input.
(a)
What peak deviation remains?
Check
A PI controller with setpoint weight b = 0.3 and = 2 sees a setpoint step of 10 while the output is still at rest.
(a)
How big is the proportional term's initial jump?
Check
A plant has a dead time of 2 s from its input, while a measured disturbance reaches the output after 0.5 s.
(a)
How far in advance would an ideal feedforward need to act?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
Feedforward current for J = 0.0001, acceleration 100 rad/s², = 0.2, no friction?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
Static feedforward gain for process gain 1 and disturbance gain 0.5?
Check
Peak deviation if feedback alone gives 0.05 and feedforward cancels 0.6?
Check
A motor with = 0.05 N·m/A and J = 1 × 10⁻⁵ kg·m² has a fast current loop; its speed loop should cross over at 300 Hz.
(a)
What proportional speed gain, in amperes per rad/s, does that need, ignoring the current loop's lag?
Write units the way you normally would: 1.5 A/(rad/s), 1500 mA/(rad/s) and 0.0015 kA/(rad/s) are the same answer.
Check
An outer loop around an integrating plant crosses over 4 times below the bandwidth of the first-order inner loop it commands.
(a)
What phase margin does it have?
(b)
How much margin does the inner loop's lag cost?
Check
An outer loop must cross over at 10 rad/s around an integrating plant with at least 70° of phase margin.
(a)
How fast must the inner loop be?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
An inner loop crosses over 10 times faster than the outer loop's 0.1 rad/s crossover.
(a)
How much does the inner loop attenuate a disturbance entering it, at the outer crossover?
Check
A proportional position loop crosses over at 10 Hz around a fast speed loop, following a target moving at 10 rad/s.
(a)
What is the following error?
Write units the way you normally would: 1.5 rad and 1500 mrad are the same answer.
Check
A speed loop's current command is clamped at 10 A; the motor has = 0.03 N·m/A and J = 0.0001 kg·m², and is commanded from rest to 500 rad/s.
(a)
What is the largest acceleration?
Write units the way you normally would: 1.5 rad/s^2 and 1500 mrad/s^2 are the same answer.
(b)
How long does the speed take to get there at least?
Check
Speed gain for 200 Hz, = 0.05, J = 0.0001?
Check
Outer phase margin with the inner loop 6 times faster?
Check
Following error at 50 rad/s with a 5 Hz position loop?
Write units the way you normally would: 1.5 rad and 1500 mrad are the same answer.
Check
At the reference frequency, a loop has gain 10 and phase −90°. What percentage of the reference appears as tracking error?
Check
A repetitive controller sampled at 10 kHz rejects a disturbance with a 50 Hz period. How many samples of memory does its delay line need?
Check
A repetitive controller's delay line holds N = 200 samples. Up to how many harmonics of the fundamental do its poles cover, to the Nyquist frequency?
Check
A damped PR controller with = 100 and = 2 rad/s is tuned to 50 Hz. What is its resonant term's gain at 1 Hz above 50 Hz?
Check
Simulate repetitive control. A plant (a direct feedthrough for simplicity) suffers a periodic disturbance with period N = 20. The controller learns with , where (the reference is zero) and g = 0.9, starting from for the first samples. Run 40 periods and set rms_first and rms_last, the RMS error over the first and last periods.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Check
What percentage tracking error results from a loop gain of 3 at −100°?
Check
How many delay-line samples does repetitive control need for a 60 Hz period at 8 kHz?
Check
A step of 4 changes a process output by 10 in the end. The output reaches 28.3% of its change 6 s after the step, and 63.2% another 1.5 s later. Fit an FOPDT model and tune a SIMC PI with = θ.
(a)
What is τ?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(b)
What is θ?
(c)
What is ?
Check
A plant is reduced by the half rule and given a SIMC PI with = θ.
(a)
What dead time does the reduced model have?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(b)
What results?
(c)
What , the smaller of τ and 8θ?
Check
Sampled every 50 ms, a plant's data fit . A PI controller with = τ is to give a closed-loop time constant of 2 × τ.
(a)
What is τ?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
(b)
What gives that closed loop?
Check
A sine test at 2 Hz on a first-order plant reads a gain of 3 and a phase of −30°. A proportional gain = 10 then closes the loop.
(a)
What is the plant's DC gain?
(b)
Where is the closed-loop pole (as a positive rate)?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A loop's step response overshoots 15% and rings with a period of 0.2 s.
(a)
What damping ratio does a second-order fit give?
(b)
What 2% settling time does the fit predict?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A plant gain near 2 is estimated by least squares from 500 samples of an input with mean square 4, with output noise σ = 0.02.
(a)
What relative standard deviation does the estimate have?
Check
A motor (J = 0.0001 kg·m², viscous friction b = 0.0002 N·m·s, = 0.08 N·m/A) follows a trapezoidal profile: acceleration 2000 rad/s² up to a cruise speed of 100 rad/s.
(a)
What feedforward current is needed just before cruise begins?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
And during the cruise?
Check
A static feedforward cancels a measured disturbance (gain 0.5) using a model of the input gain 1 that is 30% off; the feedback loop's low-frequency gain is 20.
(a)
How much of a unit disturbance reaches the output without feedback?
(b)
And with the feedback loop as well, at low frequency?
Check
A PI controller ( = 3, = 8) drives .
(a)
Where is the closed-loop zero?
(b)
What is the closed-loop ?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(c)
And ζ?
Check
A PI controller with = 1, = 3 and setpoint weight b = 0.2 sees a setpoint step of 10 with the output at rest.
(a)
How big is its output's initial jump?
(b)
At what rate does its integral term then begin to rise?
Check
A servo motor ( = 0.03 N·m/A, J = 5 × 10⁻⁵ kg·m²) gets a proportional speed loop crossing over at 150 Hz, around a current loop 10 times faster.
(a)
What speed gain, in amperes per rad/s?
Write units the way you normally would: 1.5 A/(rad/s), 1500 mA/(rad/s) and 0.0015 kA/(rad/s) are the same answer.
(b)
What phase margin does the speed loop keep?
Check
A drive's current loop has a 1 kHz bandwidth; its speed loop is 5 times slower and its position loop 10 times slower than that.
(a)
What bandwidth does the position loop have?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
(b)
What following error does it leave at 300 rad/s, without feedforward?
Check
A temperature loop crosses over at 0.02 rad/s; the steam valve under it has a flow loop crossing at 0.5 rad/s.
(a)
How much extra does the flow loop attenuate a supply-pressure upset at the temperature loop's crossover?
(b)
What phase margin would the temperature loop keep if its own plant were an integrator?
Check
A speed loop clamps its current command at 10 A. The motor has = 0.05 N·m/A and J = 0.0001 kg·m².
(a)
What's the least time to reach 1000 rad/s from rest?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
A grid inverter's current loop has gain 20 at −100° at the line frequency 60 Hz; it's sampled at 20 kHz.
(a)
What percentage tracking error does a PI controller leave at the line frequency?
(b)
How many samples of memory would a repetitive controller need?
Check
Where does cross 0 dB?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
What's the phase margin of ?
Check
What's the gain of at 30 rad/s, in decibels?
Check
A loop gain has 4 poles and 1 zeros. What's its magnitude slope far above every corner?
Check
A loop contains a 0.5 ms delay. How much phase does it lose at 100 rad/s?
Check
What's the phase of at 10 rad/s?
Check
A loop picks up a 30 ms delay.
(a)
Where does it cross over (the delay doesn't change that)?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
What phase margin remains with the delay?
Check
Crossover of ?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
Phase lost to a 1 ms delay at 20 rad/s?
Check
Phase margin of ?
Check
Where does the Nyquist plot of cross the negative real axis?
Check
A loop has 1 open-loop poles in the right half-plane, and its Nyquist plot encircles −1 a net 1 times clockwise. How many closed-loop poles are in the right half-plane?
Check
A plant has an unstable pole at +1 and a stable one at −3. Under gain K, . What's the least K that stabilizes it?
Check
Where does the Nyquist plot of cross the negative real axis?
Check
A type-1 loop with K = 2, = 0.2 s and = 0.5 s. What vertical line does its Nyquist plot approach as ω → 0?
Check
The loop is closed. How many closed-loop poles are in the right half-plane?
Check
A plant with an unstable pole at +1 is under proportional control: .
(a)
Where is the closed-loop pole?
(b)
By what factor could the gain fall before the loop goes unstable?
Check
Real-axis crossing of ?
Check
Real-axis crossing of ?
Check
Z for P = 2, N = 0 clockwise?
Check
What's the gain margin of in decibels?
Check
A loop has a 45° phase margin at a 2 rad/s crossover. What's its delay margin?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
A loop has K = 10 s⁻¹ and T = 5 ms. What's its phase margin?
Check
An integrator with a 10 ms delay in the loop, . What's the largest K before it oscillates?
Check
A loop's peak sensitivity is = 1.4. What phase margin is it guaranteed?
Check
A loop has ζ = 0.5. What's its phase margin?
Check
A loop's sensitivity peaks at = 1.4.
(a)
What gain margin is guaranteed, as a factor?
(b)
What phase margin?
Check
Gain margin of in dB?
Check
Delay margin: 35° at 10 rad/s?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
Guaranteed gain margin (as a factor) for = 1.5?
Check
A lead compensator has = 5. What's the most phase it adds?
Check
A lead must add 35° at its peak. What ratio does it need?
Check
A lead has its zero at 10 rad/s and its pole 3 times higher. Where does it add the most phase?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A lead with α = 6 is centered on 40 rad/s to make cross there. What does that take?
Check
A lag with its zero at 1 rad/s and pole at 0.5 rad/s: how much phase does it cost at a 10 rad/s crossover?
Check
How much gain does a lead with α = 3 add at its center frequency, relative to its DC gain?
Check
A loop crosses over with a 45° phase margin, and a PI zero is placed a factor 5 below the crossover.
(a)
What phase margin remains?
(b)
How much does it raise the gain at the old crossover?
Check
Lead's maximum phase for α = 8?
Check
α for 40° of lead?
Check
Lag's phase at 5 rad/s, zero 0.5, pole 2?
Check
The loop .
(a)
Crossover?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
Phase margin?
(c)
Gain at 15 rad/s?
Check
A loop crossing at 20 rad/s with 55° of phase margin; a 2 ms delay is added.
(a)
Phase the delay costs at crossover?
(b)
Delay margin before the delay was added?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
; and a loop with 5 poles and 1 zeros.
(a)
First loop's phase at 20 rad/s?
(b)
Second loop's high-frequency slope?
Check
.
(a)
Phase crossover?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
Where the Nyquist plot crosses the negative real axis?
(c)
Gain margin in dB?
Check
.
(a)
Negative real-axis crossing?
(b)
The vertical asymptote Re L approaches as ω → 0?
Check
A plant with poles at +0.5 and −4 under gain K; separately, a loop with P = 2 and N = 3.
(a)
Least K to stabilize the first?
(b)
Closed-loop RHP poles of the second?
Check
with K = 4 s⁻¹ and T = 4 ms.
(a)
Phase margin?
(b)
Gain margin as a factor?
Check
A loop with peak sensitivity = 1.6.
(a)
Guaranteed phase margin?
(b)
Guaranteed gain margin in dB?
(c)
Closest approach of the Nyquist plot to −1?
Check
The standard loop with ζ = 0.5.
(a)
Phase margin?
(b)
Closed-loop overshoot?
Check
A lead with zero at 3 rad/s and α = 6.
(a)
Maximum phase?
(b)
Where?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(c)
Gain added there?
Check
Lead design: make cross at 50 rad/s with 55° of margin.
(a)
Phase the lead must add?
(b)
α?
(c)
?
Check
A lag (zero 0.8 rad/s, pole 0.4 rad/s) on a loop crossing at 8 rad/s with = 20.
(a)
Phase cost at crossover?
(b)
New ?
Check
A plant with an unstable pole is under proportional control: .
(a)
Where is the closed-loop pole?
(b)
How far could the gain fall before instability, in dB?
Check
A lead is evaluated at 30 rad/s.
(a)
What is its gain?
(b)
And its phase?
Check
A loop with 50° of phase margin gets integral action from a PI zero 4 times below crossover.
(a)
What margin is left?
Check
At some frequency a loop gain has magnitude 1 and phase −100°. How much are disturbances at that frequency amplified (|S|)?
Check
A loop of relative degree two has right-half-plane poles at +2 and, if not zero, +0 rad/s. What's ?
Check
A plant has an RHP zero at +10 and an RHP pole at +1 rad/s. What's the smallest peak sensitivity achievable?
Check
A boost converter has L = 47 µH, a 5 Ω load and duty cycle 0.3. Where's its right-half-plane zero?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A stable loop holds |S| at 1/2 for all ω below 1 rad/s. If the compensating rise is spread evenly from 1 to 20 rad/s (and |S| = 1 above), what |S| does that band have?
Check
By the rule , how fast must the loop balancing a 0.5 m inverted pendulum cross over?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
At some frequency a loop gain has magnitude 1 and phase −120°.
(a)
What is |S| there?
(b)
And |T|?
Check
|S| for |L| = 0.3 at −120°?
Check
Lowest with an RHP zero at 6 and pole at 0.5?
Check
Boost RHP zero: L = 100 µH, R = 2 Ω, D = 0.2?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A closed loop's |T| peaks at 1.3.
(a)
Up to what relative model error, of any phase, is stability guaranteed?
Check
A loop may contain an unmodeled delay of up to 20 ms.
(a)
How large is the relative uncertainty at 50 rad/s?
(b)
What's the largest |T| allowed at that frequency?
Check
A loop has a gain margin of 3 (a factor) and the plant's gain may be up to 20% higher than modeled.
(a)
What gain margin remains in the worst case?
(b)
In decibels?
Check
At one frequency a loop has |S| = 0.2 and |T| = 0.9; the performance weight is = 10 and the uncertainty weight |W| = 0.5.
(a)
What is there (robust performance needs it below 1)?
Check
Two stable systems in a feedback loop have peak gains 2 and 0.1.
(a)
What is the product the small-gain theorem tests?
(b)
How large could the second system's peak gain be, with the first unchanged, and stability still guaranteed?
Check
A loop was designed for θ = 0 with = 2 s; the actual delay is 0.1 s.
(a)
What phase margin does it have?
(b)
What's the largest delay it could tolerate?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
Relative error tolerated when |T| peaks at 1.3?
Check
|W| of a 2 ms delay at 20 rad/s?
Check
Worst-case gain margin: 2.5, gain up to 30% high?
Check
At ωθ = 1, how far does the first-order Padé approximation's phase lag fall short of the true delay's?
Check
A plant has K = 1 and θ = 0.1 s. What proportional gain gives a 60° phase margin?
Check
A digital loop sampled at 10 kHz crosses over at 2 kHz. How much phase do the hold and one sample of computation delay cost there?
Check
Where's the right-half-plane zero of the first-order Padé approximation of a 1 s delay?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
With a Smith predictor, a PI controller ( = τ) is tuned for with K = 0.5, τ = 2 s, θ = 5 s. What gives a delay-free closed-loop time constant of 4 s?
Check
With a perfect model, a Smith-predictor loop responds like with = 1 s and θ = 2 s. When does it settle within 2%?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A delay is approximated at ωθ = 1.
(a)
By how much does the first-order Padé approximation understate the phase lag?
(b)
And the second-order one?
Check
for 55° margin on , θ = 0.05 s?
Check
Phase lost to 1.5 samples at 20 kHz, 1 kHz crossover?
Check
First-order Padé phase shortfall at ωθ = 1.5?
Check
A loop's |T| peaks at 1.4, and its plant's gain may drift by an unknown factor of any phase at each frequency.
(a)
Up to what relative error is stability guaranteed?
(b)
What pure gain increase (zero phase) does that guarantee, in dB?
Check
A loop with |T| = 2 at 20 rad/s may contain up to 20 ms of unmodeled delay.
(a)
What is |WT| at that frequency?
Check
A loop's gain margin is 4; its plant's gain is known only to within +25%.
(a)
How much gain margin remains in the worst case?
Check
At one frequency |S| = 0.1, |T| = 0.8, the performance weight is 3 and the uncertainty weight 0.4.
(a)
What is ?
(b)
How large could the uncertainty be at that frequency with robust performance still met?
Check
A loop has = 1 s and θ = 0.05 s.
(a)
What is its phase margin?
(b)
How much more delay can it take?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A loop's sensitivity peaks at 1.6.
(a)
What gain margin is guaranteed, in dB?
(b)
What phase margin?
Check
A loop of relative degree two has an unstable open-loop pole at +1 rad/s. It holds |S| at 0.3 from 0 to 10 rad/s.
(a)
If the rest of Bode's integral is spread evenly from 10 to 50 rad/s, what average ln|S| does that band need?
Check
A plant has a right-half-plane zero at +10 and pole at +0.5 rad/s.
(a)
What is the smallest achievable ?
(b)
By how much does the rule-of-thumb crossover window () exceed a factor of one, as the ratio of its ends?
Check
The loop with K = 6.
(a)
Where does its Nyquist plot cross the negative real axis, as a magnitude?
(b)
How many closed-loop poles are in the right half-plane?
Check
A loop .
(a)
Where does it cross over?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
What is its delay margin?
Check
A plant was modeled with τ = 1 s, but the true time constant may be up to 10% longer.
(a)
How large is the relative model error at 2 rad/s?
Check
Two stable systems are connected in a feedback loop; one has peak gain 1.
(a)
Below what peak gain must the other be for the small-gain theorem to guarantee stability?
(b)
If the other's peak gain is 0.2, by what factor could the first one's grow before the guarantee is lost?
Check
At some frequency the loop gain has magnitude 2 and phase −100°.
(a)
What is |S|?
(b)
What is |T|?
Check
A loop has K = 2 s⁻¹ and θ = 0.05 s.
(a)
What is its gain margin?
(b)
And its phase margin?
Check
. What's its larger eigenvalue?
Check
A 2 × 2 system matrix has trace −4 and determinant 10. What's the damping ratio of its poles?
Check
starts at x(0) = (1, 0). What's at t = 2?
Check
A companion-form model , , . What's its DC gain?
Check
starts at x(0) = (0, 1). What's at t = 1?
Check
A motor's state matrix has R = 1 Ω, L = 0.5 mH, = 0.08, J = 5 × 10⁻⁵ kg·m² and b = 10⁻⁵ N·m·s. What's det A?
Check
A series RLC circuit has R = 20 Ω, L = 0.1 mH and C = 10 µF, with states i and .
(a)
What is , the square root of the state matrix's determinant?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
What is ζ, from the trace?
Check
Damping ratio for trace −3, determinant 4?
Check
from (1, 0) with poles −0.5, −4 in companion form?
Check
DC gain of ?
Check
A plant in companion form has characteristic polynomial and . What first gain places the closed loop at = 3 rad/s, ζ = 0.8?
Check
The same companion-form plant has = 1. What gives = 5, ζ = 0.9?
Check
, . What's ?
Check
A double integrator gets state feedback placing its poles at −1 and −4. What's the velocity gain ?
Check
A servo has τ = 50 ms and = 5. What velocity gain gives = 60 rad/s and ζ = 1?
Check
A first-order plant gets state feedback plus integral action, . What puts the closed-loop at 15 rad/s?
Check
A plant gets state feedback for poles at = 20 rad/s, ζ = 0.6.
(a)
What is ?
(b)
What is ?
(c)
What reference gain gives unit DC gain?
Check
for = 4 on ?
Check
for ζ = 0.8, = 3, with = 0.5?
Check
Position gain placing a double integrator's poles at −2, −6?
Check
A plant gets integral state feedback with poles at = 10 rad/s, ζ = 0.9.
(a)
What is k?
(b)
What is ?
Check
A double integrator gets integral state feedback with all three closed-loop poles at −5.
(a)
What is the position gain ?
(b)
The velocity gain ?
(c)
The integral gain ?
Check
A plant runs under with k = 3, and a constant disturbance d = 2 appears.
(a)
How far does the output shift?
(b)
And with an integral state added (any stable gains)?
Check
State feedback with k = 3 was designed for , with set for unit DC gain; the real input gain is 20% different.
(a)
What is ?
(b)
Where does the real plant's output settle for a unit step?
Check
An integral state-feedback design places its closed-loop poles at = 10 rad/s, ζ = 0.5.
(a)
About how long do disturbances take to be removed (2% settling)?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
for = 20 on ?
Check
for a double integrator with triple pole at −4?
Check
Output shift per unit input disturbance without integral, a = 1, b = 3, k = 4?
Check
At one frequency a loop gain has magnitude 0.8 and phase −110°.
(a)
|S|?
(b)
|T|?
Check
A loop of relative degree two with unstable poles at +1 and +0.5; separately, a stable loop with |S| = 1/8 below 6 rad/s.
(a)
for the first?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
Second loop's |S| if the excess is spread evenly from 6 to 15 rad/s?
Check
A plant with an RHP zero at +20 and an RHP pole at +1 rad/s.
(a)
Least achievable ?
(b)
Lowest crossover by the rule of thumb?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(c)
Highest crossover by the rule of thumb?
Check
A boost converter: L = 33 µH, R = 4 Ω, D = 0.25.
(a)
RHP zero?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
Crossover limit by the half-the-zero rule?
Check
Padé approximations of a 0.3 s delay.
(a)
First-order Padé's phase shortfall at ωθ = 1.2?
(b)
Its RHP zero?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
The plant with K = 1.5, θ = 0.08 s, under proportional control.
(a)
for 60° of phase margin?
(b)
Largest stable ?
(c)
Delay margin at the first gain?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
A digital loop sampled at 8 kHz crosses at 0.3 kHz with 65° of margin before sampling effects.
(a)
Phase lost to 1.5 samples of delay?
(b)
Margin left?
Check
A Smith predictor around : K = 0.4, τ = 3 s, θ = 8 s, target = 4 s.
(a)
PI (with = τ)?
(b)
2% settling time with a perfect model?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
; and another 2 × 2 matrix with trace −3, determinant 15.
(a)
Larger eigenvalue of the first?
(b)
Damping ratio of the second?
Check
Companion form with poles −0.5 and −3, input gain 5: .
(a)
from y(0) = 1, = 0, u = 0?
(b)
DC gain?
Check
, .
(a)
?
(b)
Sum of the open-loop poles?
Check
A servo with τ = 40 ms and = 4, placed at = 70, ζ = 0.9.
(a)
Position gain ?
(b)
Velocity gain ?
Check
with state feedback and integral action, placed at = 12, ζ = 1.
(a)
?
(b)
k?
Check
A delay is replaced by a second-order Padé approximation, evaluated at ωθ = 2.
(a)
What phase lag does the approximation give?
(b)
What does the true delay give?
Check
A plant gets state feedback for = 80 rad/s, ζ = 0.6, with a reference gain for unit DC gain.
(a)
What velocity gain ?
(b)
What reference gain ?
Check
An observer for a double integrator measuring position needs error poles at = 20 rad/s, ζ = 0.6. What's ?
Check
A servo measures θ. What observer gain puts the error poles at = 100, ζ = 1?
Check
, . What's ?
Check
A controller places poles with = 10 and an observer places its poles with = 40. What's the constant term of the fourth-order closed-loop characteristic polynomial?
Check
About how long does an observer with error poles at = 200 rad/s and ζ = 0.5 take for its estimates to settle within 2%?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
A double-integrator observer has = 8, = 100. Its velocity estimate starts 1 unit off and its position estimate is right. What's the position error at t = 0.2 s?
Check
A plant with a constant unknown d is measured through x. An observer estimates x and d with error poles at = 5 rad/s, ζ = 1.
(a)
What is ?
(b)
What is ?
Check
for a double-integrator observer at = 8, ζ = 0.7?
Check
for a servo with damping 5 s⁻¹, observer at = 80, ζ = 0.8?
Check
Observer settling time at = 30, ζ = 0.6?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
gets the LQR for . Where's the closed-loop pole?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
For the same plant and cost, what's the LQR gain K?
Check
A double integrator gets the LQR with Q = diag(81, 0), R = 1. What's its velocity gain?
Check
By Bryson's rule, a state may reach 0.2 and the input 5. What's the weight ratio q/r?
Check
with cost weights q = 8, r = 2, starting from x = 2. What's the minimum cost?
Check
For , what weight ratio q/r makes the LQR put the pole at −20?
Check
The plant gets the LQR for , starting from x = 1.
(a)
What is P?
(b)
What is the gain K?
(c)
What is the minimum cost?
Check
LQR pole for = 0.5, b = 1, q = 20, r = 2?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
Natural frequency of a double integrator's LQR with q = 625, r = 1?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
Bryson's q/r for = 0.05, = 3?
Check
A random walk with step variance 0.01 is measured with noise variance 0.1. What's the steady-state Kalman gain?
Check
For the same filter, what's the standard deviation of the estimate after each update?
Check
A constant is measured 4 times with noise σ = 1. What's the best estimate's standard deviation?
Check
A prior estimate 10 with variance 0.02 meets a measurement of 10 + (1) with noise variance 1. What's the updated estimate?
Check
A continuous-time state is measured as , with noise intensities = 0.1, = 1. What's the steady-state Kalman gain?
Check
A prior variance 0.04 meets a measurement with noise variance 0.1. What's the variance after the update?
Check
Two independent sensors measure the same quantity, with σ = 0.5 and σ = 0.1.
(a)
What is the standard deviation of the best combination?
(b)
What weight does the first sensor get?
Check
Steady-state K for Q = 0.0004, R = 0.04?
Check
Update 5 (variance 0.1) with a reading 2 higher (variance 4)?
Check
σ of the average of 9 readings with σ = 0.3?
Check
A one-step MPC for minimizes . What feedback gain (with ) does it apply?
Check
With that one-step MPC gain, where is the closed-loop pole of (weights = 2, = 1)?
Check
An MPC has 2 inputs and a horizon of 5 steps. How many decision variables does each optimization have?
Check
An unstable plant has its input limited to 2. Beyond what can no input sequence bring it back?
Check
Compute MPC gains by the backward Riccati recursion for , = 1, terminal weight , input weight r = 0.5. Write k0(N), the first-step gain for horizon N. Set K_lqr (iterate the recursion 10 000 times), N_match, the smallest horizon with , and K1 = k0(1).
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Check
What is the one-step MPC gain for with weights 1 and 1?
Check
How many variables does an MPC with 3 inputs and an 8-step horizon optimize?
Check
A continuous pole with real part −75 s⁻¹ is sampled every 2 ms. What's the radius of the discrete pole?
Check
A plant with τ = 5 ms is sampled every 0.5 ms with a hold. What's Γ, the input coefficient of the discrete model?
Check
The same sampled plant gets . What's the largest stable ?
Check
A PI controller ( = 1, = 2 ms) is converted by Tustin's method at T = 2 ms. What's the coefficient on ?
Check
A Tustin-converted filter sampled at 1 kHz needs its corner at exactly 200 Hz. What corner should the analog prototype have?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
Check
A continuous pole pair with damped frequency 100 rad/s is sampled every 1 ms. At what angle do the discrete poles sit?
Check
A plant with τ = 10 ms is sampled every 1 ms with a hold.
(a)
What is Φ?
(b)
What proportional gain puts the closed-loop pole at z = 0?
(c)
What fraction of a step reference does the output settle to?
Check
Discrete pole radius: real part −20, T = 1 ms?
Check
Tustin PI coefficient on : = 0.5, = 5 ms, T = 2 ms?
Check
Prewarped analog corner for 100 Hz at 2 kHz?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
Check
A continuous design has ζ = 0.7, = 5 rad/s, and the controller samples every 50 ms.
(a)
What radius should the discrete poles have?
(b)
At what angle?
Write units the way you normally would: 1.5 rad and 1500 mrad are the same answer.
Check
A loop crosses over at 100 rad/s and samples at 0.2 kHz, updating its output one sample after each measurement.
(a)
How much phase do the hold and the computation delay cost at crossover?
Check
A loop crosses over at 100 rad/s and may lose at most 5° to a hold plus one sample of computation.
(a)
What is the lowest sample rate?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A first-order filter with τ = 1 s runs at 1 kHz, its pole stored with 24 fractional bits.
(a)
How far from 1 is the exact pole?
(b)
What's the worst relative error in τ from rounding?
Check
A velocity-form PI ( = 0.5, = 0.05 per sample) applied 0.8 last sample with error 2; now the error is −1.
(a)
What output does it compute before clamping?
Check
A loop must settle within 0.5 s (2%) and samples every 1 ms.
(a)
Inside what radius must every closed-loop pole lie?
Check
Discrete pole radius for ζ = 0.6, = 10, T = 10 ms?
Check
Phase lost at 50 rad/s sampling at 1 kHz with one sample of computation?
Check
Pole radius for 2% settling in 0.1 s at T = 1 ms?
Check
What's the describing function of a ±5 relay at input amplitude 0.2?
Check
A ±1 relay drives . What amplitude of oscillation does the describing function predict?
Check
A unit-slope saturation is driven at 2 times its limit. What's its describing function?
Check
A relay drives . What's the period of the predicted limit cycle?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A plant with τ = 5 ms is driven flat out at 24 V from rest. How long until it reaches 0.8 of its full-drive output?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
For , solve the Lyapunov equation with q = 1. What's P?
Check
A dead zone of half-width 0.5 (slope 1 outside it) is driven by a sine of amplitude 1.
(a)
What is the describing function of a unit-slope saturation with limit D at this amplitude?
(b)
What is the dead zone's describing function?
Check
Relay describing function: ±2, amplitude 0.5?
Check
Saturation describing function at 2.5 times the limit?
Check
Relay limit-cycle period for ?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
Solve for .
(a)
What is ?
(b)
What is ?
(c)
What is ?
Check
The scalar system has the Lyapunov function with .
(a)
What is P?
(b)
At what rate does V decay, in s⁻¹?
Check
A damped pendulum 0.5 m long hangs at rest and is struck.
(a)
What energy per unit , in s⁻², does it need to reach the top?
(b)
Below what initial angular speed is it guaranteed never to go over?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
The system is studied with .
(a)
Within what |x| is negative?
Check
has the Lyapunov function with ; the state starts at (3, 0).
(a)
What is V at the start?
(b)
What is , the integrated squared state?
Check
P for with ?
Check
for the companion matrix with k = 4, Q = I?
Check
Guaranteed no-flip speed for a 0.5 m pendulum?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A double-integrator observer measuring position, error poles at = 40, ζ = 0.6.
(a)
?
(b)
?
(c)
Settling time of the estimates?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
A servo measuring θ, observer at = 120, ζ = 0.8.
(a)
?
(b)
?
Check
with ; a controller at = 6 with an observer at = 25.
(a)
?
(b)
Constant term of the closed-loop polynomial?
Check
LQR for with q = 20, r = 2, from x(0) = 2.
(a)
Closed-loop pole?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
Gain?
(c)
Minimum cost?
Check
A double integrator's LQR with Q = diag(256, 0), R = 1.
(a)
Position gain?
(b)
Velocity gain?
(c)
Closed-loop natural frequency?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
Bryson's rule with = 0.02, = 6; and a target LQR pole at −6 for .
(a)
q/r by Bryson?
(b)
q/r for the target pole?
Check
A random walk (step variance 0.02) measured with noise variance 0.05.
(a)
Steady-state Kalman gain?
(b)
Estimate's standard deviation?
Check
A prior 12 (variance 0.05) and a measurement 1.5 away from it (variance 2).
(a)
Updated estimate?
(b)
Updated variance?
Check
A continuous-time Kalman filter for , y = x + v, = 0.5, = 2.
(a)
Gain L?
(b)
Error pole?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A plant , τ = 3 ms, sampled every 0.5 ms; and a pole pair sampled the same way.
(a)
Γ?
(b)
Largest stable proportional gain?
(c)
Radius of the sampled pole pair?
Check
Tustin conversion of a PI ( = 0.3, = 3 ms) at T = 2 ms; and prewarping a 350 Hz corner at 1 kHz.
(a)
Coefficient on ?
(b)
Coefficient on ?
(c)
Prewarped analog corner?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
Check
A ±1 relay drives .
(a)
Predicted period?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(b)
Predicted amplitude?
(c)
Ultimate gain a relay test would report?
Check
A saturation driven at 3 times its limit; a plant with τ = 4 ms driven flat out to 0.9 of its full output; with Lyapunov weight q = 2.
(a)
Saturation's describing function?
(b)
Time to reach 0.9 of full output?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
(c)
Lyapunov P?
Check
A plant with constant unknown d gets an observer estimating x and d, with error poles at = 2, ζ = 0.9.
(a)
What is ?
(b)
What is ?
Check
A dead zone of half-width 0.1 is driven at amplitude 0.15.
(a)
What is its describing function?
Check
A one-step MPC controls with weights 1 and 1, and 3.
(a)
What gain does the unconstrained one-step MPC apply?
(b)
Where is the closed-loop pole without saturation?
Check
A 2 × 2 plant has gain matrix .
(a)
What is ?
(b)
What is ?
(c)
What is loop 1's gain when loop 2 holds its output perfectly?
Check
A shower mixes 0.5 kg/s of hot water at 60 °C with 0.7 kg/s of cold at 10 °C.
(a)
What is the mixed temperature?
(b)
How many °C does the temperature rise per extra kg/s of hot water?
Check
A 2 × 2 plant has . A static decoupler is placed ahead of it.
(a)
What is ?
(b)
What is ?
Check
Find the condition number of .
(a)
What is ?
Check
A plant has , with strong cross gains.
(a)
What is for the diagonal pairing?
(b)
What is the relative gain of the off-diagonal pairing?
Check
for K = [[1, 0.5], [1, 4]]?
Check
Loop 1's closed-loop-2 gain for K = [[2, 1], [3, 6]]?
Check
for coupling κ = 0.5?
Check
A plant (a negative a means it's unstable) gets integral state feedback with closed-loop poles at = 20 rad/s, ζ = 1.
(a)
What is k?
(b)
What is ?
Check
A double integrator gets integral state feedback with all three poles at −10.
(a)
What position gain ?
(b)
What integral gain ?
Check
State feedback with reference gain was designed for with k = 2.5. The real input gain is 20% off, and a constant disturbance of 1 adds to u.
(a)
Where does the output settle for a unit setpoint?
(b)
Where does it settle with a stable integral state added instead?
Check
A design wants ζ = 0.7, = 10 rad/s, sampled every 10 ms.
(a)
What is minus the z coefficient of the desired discrete polynomial?
(b)
And its constant term?
Check
A loop crosses over at 100 rad/s. Its hold costs half a sample and its computation 1 sample(s) more; at most 5° may be lost.
(a)
What is the lowest sample rate?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
Check
A velocity-form PI ( = 0.5, = 0.02 per sample) last applied −0.5 with error 2; the new error is −1.
(a)
What does it compute before clamping?
Check
A first-order filter with τ = 2 s at 1 kHz stores its pole with 20 fractional bits.
(a)
What is the worst relative error in τ?
Check
Solve for .
(a)
What is ?
(b)
What is det P?
Check
The system has a Lyapunov function .
(a)
Within what |x| does V decrease?
(b)
What is the largest level of V inside that region?
Check
A damped pendulum 1 m long is released at rest from 10° off vertical.
(a)
What is its starting energy per unit ?
(b)
What angular speed can it never exceed?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A 2 × 2 plant has .
(a)
What is ?
(b)
What is loop 1's gain with loop 2 closed tightly?
Check
A static decoupler is built for .
(a)
What is ?
(b)
What is ?
Check
Find the condition number of .
(a)
What is ?
Check
A mixer combines 0.4 kg/s of hot fluid at 55 °C with 0.8 kg/s at 10 °C; its outputs are total flow and temperature.
(a)
How many °C does the temperature change per extra kg/s of the cold stream?
(b)
What is the relative gain for pairing flow with the hot stream?
Check
What gain margin should margins report for ?
Check
What first gain should place return for a double integrator with poles −1, −3?
Check
What overshoot should step_response show for ζ = 0.6?
Check
In the motor model with R = 1 Ω, L = 0.2 mH and = 0.08, what's the entry ?
Check
Dominant poles with ζ = 0.707 and = 85: what's their real part's magnitude?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
With a current gain = 0.5 and , what's the current row's diagonal entry of A − BK (R = 1 Ω, L = 1 mH)?
Check
A motor ( = 0.03, R = 1 Ω, b = 0.0004, J = 6 × 10⁻⁵) gets proportional speed control = 0.2 V per rad/s.
(a)
DC gain, rad/s per volt?
Write units the way you normally would: 1.5 rad/s/V and 1500 mrad/s/V are the same answer.
(b)
Closed-loop time constant?
(c)
Steady error to a step?
Check
PI control with = τ for , τ = 10 ms, a 3 ms closed loop, implemented at 5 kHz by Tustin.
(a)
?
(b)
Coefficient on ?
(c)
Samples per closed-loop time constant?
Check
.
(a)
Critical gain?
(b)
Gain margin at K = 40?
(c)
Period of a relay-test oscillation?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
placed at , tracking a ramp of 2 rad/s.
(a)
K?
(b)
Ramp lag?
Write units the way you normally would: 1.5 rad and 1500 mrad are the same answer.
(c)
Overshoot?
Check
Frequency-domain lead for at 50 rad/s with 55° of margin.
(a)
Lead needed?
(b)
α?
(c)
Lead zero?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
The plant (K = 2, θ = 0.02 s) under proportional control; and a digital loop at 5 kHz crossing at 1 kHz.
(a)
for 60° of margin?
(b)
Delay margin?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
(c)
Phase the digital loop loses to 1.5 samples?
Check
A boost converter (L = 22 µH, R = 3 Ω, D = 0.35), and a plant whose RHP zero is that one with an RHP pole at 8000 rad/s.
(a)
RHP zero in rad/s?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
Least ?
Check
, .
(a)
Larger eigenvalue?
(b)
?
Check
A servo (τ = 30 ms, = 6) placed at = 60, ζ = 0.7, with an observer measuring θ at = 300, same ζ.
(a)
Velocity gain ?
(b)
Observer gain ?
Check
, y = x + v: an LQR with weights q = 25, r = 1, and a Kalman filter with intensities = 1, = 0.1.
(a)
LQR pole?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
Kalman error pole?
Check
A random walk (Q = 0.002) measured with variance R = 0.1, in steady state; the prior is 60 and a reading arrives 2 away.
(a)
Steady-state gain?
(b)
Updated estimate?
Check
A relay test (±2) gives amplitude 0.4 and period 10 s; separately, an FOPDT plant with K = 4, τ = 8 s, θ = 1 s.
(a)
Ziegler–Nichols PID ?
(b)
Its ?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(c)
SIMC for the FOPDT plant ( = θ)?
Check
A maglev rig at a 4 mm gap; a 0.3 m inverted pendulum.
(a)
Least crossover for the maglev loop by the 2p rule?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
Least crossover for the pendulum loop?
Check
Three independent sensors measure one quantity with σ = 0.3, 0.1 and 2.
(a)
What standard deviation does the best combination have?
(b)
What weight goes to the second sensor?
Check
A position loop crossing at 5 Hz follows a target at 50 rad/s; a velocity feedforward supplies 0.95 of the needed speed command.
(a)
What following error remains?
Write units the way you normally would: 1.5 rad and 1500 mrad are the same answer.
Check
Design a lead for whose zero cancels the pole at −2, placing the closed-loop poles at .
(a)
Where does the lead's pole go?
(b)
What is ?
(c)
What overshoot should the step response show?
Check
A PI controller with = τ cancels the pole of to give a closed-loop time constant of 0.5 × τ.
(a)
What ?
(b)
How long does a setpoint step take to settle within 2%?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A PID cancels both poles of for a closed-loop time constant of 1 s.
(a)
What ?
(b)
What ?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(c)
What ?
Check
A process gets a SIMC PI with = θ.
(a)
What ?
(b)
What , the smaller of τ and ?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A relay of ±0.5 drives a loop into a 10 s limit cycle of amplitude 0.1. Tune a Ziegler–Nichols PID.
(a)
What ?
(b)
What ?
Check
A lead must add 45° at the new crossover of 10 rad/s.
(a)
What pole-to-zero ratio α does it need?
(b)
Where does its zero go?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A lag raises by 5 with its zero a decade below the 5 rad/s crossover.
(a)
Where does its pole go?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
How much phase does it cost at crossover?
Check
A plant gets state feedback for = 50 rad/s, ζ = 0.7, and an observer three times faster with the same damping, measuring y.
(a)
What is ?
(b)
What is the observer gain ?
Check
A plant gets an LQR with Bryson's weights: x should stay within 0.1 and u within 12.
(a)
What is q/r?
(b)
Where is the closed-loop pole?
Check
A random walk with step variance 0.01 is measured with noise variance 0.1.
(a)
What is the steady-state Kalman gain?
Check
A plant (τ in ms) is sampled every 10 ms. Design a deadbeat proportional gain.
(a)
What puts the pole at z = 0?
(b)
What fraction of the setpoint does the output reach?
Check
A plant gets proportional control for a 45° phase margin.
(a)
What gain?
(b)
What gain margin does that leave, as a factor?
Check
A Smith predictor controls with a PI ( = τ) designed for = 3 s on the delay-free model.
(a)
What ?
(b)
With a perfect model, when does a setpoint step settle within 2%?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A thermal stage has 2 K/W to ambient and 20 J/K of heat capacity, with a 60 W heater. It must rise 114 K above ambient.
(a)
What is its time constant?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(b)
At full power, how long does the rise take?
Check
A DC motor has R = 0.5 Ω, L = 0.2 mH, = 0.1 and J = 0.0001 kg·m², with negligible friction.
(a)
What is its electrical time constant?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
(b)
And its mechanical time constant?
Check
A buck converter's output filter has L = 22 µH and C = 10 µF, feeding a 20 Ω load.
(a)
Where is its double pole?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
What is the resonance's Q?
Check
A boost converter drives 10 Ω at duty cycle 0.7 through 10 µH.
(a)
Where is its right-half-plane zero?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
What crossover does the rule allow, at most?
Check
A second-order PLL has = 1000 rad/s and ζ = 0.5.
(a)
What is its noise bandwidth?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
(b)
About how long does it take to settle after a frequency step?
Check
A loop's sensor adds white noise of 0.01 units/√Hz, and the closed loop T is first order with a 10 Hz bandwidth.
(a)
What rms noise reaches the output?
Check
An encoder gives 2048 counts per revolution, and speed is estimated by differencing counts every 0.1 ms.
(a)
What is the position resolution?
Write units the way you normally would: 1.5 mrad, 1500 µrad and 0.0015 rad are the same answer.
(b)
What is the smallest nonzero speed estimate?
Check
An op amp with 1 MHz gain-bandwidth and 120 dB of DC gain is used as a noninverting amplifier with gain 10.
(a)
What closed-loop bandwidth results?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
What is its DC gain error?
Check
A motor current loop's PI zero cancels the winding's pole (L = 2 mH, R = 0.2 Ω) to cross over at 5 kHz.
(a)
What proportional gain, in volts per ampere?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
What integral gain, in volts per ampere-second?
Check
A robot balances an inverted pendulum 0.5 m long.
(a)
Where is the unstable pole?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
If the loop crosses over at twice the pole and samples 20 times faster than crossover, what sample rate is needed?
Check
A disturbance at 1 Hz must be attenuated by 20 dB by a loop with .
(a)
What |L| does that need at 1 Hz?
(b)
What crossover does that require?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A digital controller samples every 0.05 ms and needs 0.1 ms to compute, applying its output as soon as it's ready; the loop crosses over at 1000 rad/s.
(a)
How much phase do the hold and the computation cost?
Check
A furnace with gain K = 0.5 °C per percent of heater drive, τ = 60 s and θ = 30 s gets a SIMC PI with = θ.
(a)
What ?
(b)
Roughly when does a setpoint step settle, the delay plus four closed-loop time constants?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A valve can change position at most 5% per second and must move 10%.
(a)
How long does the move take at best?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
An amplifier with open-loop gain 5000 and β = 0.01; separately, a loop of gain 39 facing a 25 mV output disturbance.
(a)
Closed-loop gain?
(b)
Disturbance left?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
Specifications (3% overshoot, 0.25 s settling); and a system with = 30, ζ = 0.6.
(a)
Least ζ?
(b)
Least σ?
(c)
The system's peak time?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
.
(a)
Critical gain?
(b)
Oscillation frequency?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A type-0 loop ; a type-1 loop following 0.5 units/s.
(a)
Type-0 step error?
(b)
Type-1 ramp error?
Check
The locus of .
(a)
Centroid?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
Breakaway?
(c)
-axis crossing?
Check
Root-locus lead design for at , zero at −2.5.
(a)
Deficiency?
(b)
Lead pole?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
Ultimate-gain test: = 3, = 1.5 s; and an FOPDT plant (K = 2, τ = 30 s, θ = 0.5 s).
(a)
Ziegler–Nichols PID ?
(b)
SIMC with = θ?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
.
(a)
Crossover?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
Phase margin?
(c)
Delay margin?
Check
.
(a)
Negative real-axis crossing?
(b)
Gain margin?
Check
A lead with α = 3 and its zero at 4 rad/s.
(a)
Maximum phase?
(b)
Where?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A loop gain of magnitude 0.6 at −130°; a loop with = 2.
(a)
|S| there?
(b)
Guaranteed phase margin of the second?
Check
A 2 × 2 system with trace −4 and determinant 25; a companion-form system with poles −2, −8 starting at (1, 0).
(a)
First system's ζ?
(b)
Second system's at t = 0.3?
Check
Companion form placed at = 15, ζ = 0.9; and with integral action at the same .
(a)
?
(b)
?
(c)
Integral gain of the second?
Check
A double-integrator observer at = 20, ζ = 0.7; and the double integrator's LQR with q = 625, r = 1.
(a)
Observer ?
(b)
LQR velocity gain?
Check
A random walk (Q = 0.001) seen with noise variance 0.2; a plant , τ = 25 ms, sampled every 2 ms.
(a)
Steady-state Kalman gain?
(b)
Largest stable sampled proportional gain?
Check
A ±1 relay drives ; a saturation is driven at 1.5 times its limit.
(a)
Limit-cycle amplitude?
(b)
Saturation's describing function?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to S9