S9 · Problem set 8
Problem set 8: observers and separation, LQR, Kalman filtering, sampled-data control and describing functions
These problems cover lessons 37 to 43: observer design and the separation principle, the linear-quadratic regulator and Bryson's weights, the Kalman filter in discrete and continuous time, model predictive control, sampled plants and digital controllers, and saturation, describing functions and limit cycles.
Check
A double-integrator observer measuring position, error poles at = 40, ζ = 0.6.
(a)
?
(b)
?
(c)
Settling time of the estimates?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
A servo measuring θ, observer at = 120, ζ = 0.8.
(a)
?
(b)
?
Check
with ; a controller at = 6 with an observer at = 25.
(a)
?
(b)
Constant term of the closed-loop polynomial?
Check
LQR for with q = 20, r = 2, from x(0) = 2.
(a)
Closed-loop pole?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
Gain?
(c)
Minimum cost?
Check
A double integrator's LQR with Q = diag(256, 0), R = 1.
(a)
Position gain?
(b)
Velocity gain?
(c)
Closed-loop natural frequency?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
Bryson's rule with = 0.02, = 6; and a target LQR pole at −6 for .
(a)
q/r by Bryson?
(b)
q/r for the target pole?
Check
A random walk (step variance 0.02) measured with noise variance 0.05.
(a)
Steady-state Kalman gain?
(b)
Estimate's standard deviation?
Check
A prior 12 (variance 0.05) and a measurement 1.5 away from it (variance 2).
(a)
Updated estimate?
(b)
Updated variance?
Check
A continuous-time Kalman filter for , y = x + v, = 0.5, = 2.
(a)
Gain L?
(b)
Error pole?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A plant , τ = 3 ms, sampled every 0.5 ms; and a pole pair sampled the same way.
(a)
Γ?
(b)
Largest stable proportional gain?
(c)
Radius of the sampled pole pair?
Check
Tustin conversion of a PI ( = 0.3, = 3 ms) at T = 2 ms; and prewarping a 350 Hz corner at 1 kHz.
(a)
Coefficient on ?
(b)
Coefficient on ?
(c)
Prewarped analog corner?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
Check
A ±1 relay drives .
(a)
Predicted period?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(b)
Predicted amplitude?
(c)
Ultimate gain a relay test would report?
Check
A saturation driven at 3 times its limit; a plant with τ = 4 ms driven flat out to 0.9 of its full output; with Lyapunov weight q = 2.
(a)
Saturation's describing function?
(b)
Time to reach 0.9 of full output?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
(c)
Lyapunov P?
Check
A plant with constant unknown d gets an observer estimating x and d, with error poles at = 2, ζ = 0.9.
(a)
What is ?
(b)
What is ?
Check
A dead zone of half-width 0.1 is driven at amplitude 0.15.
(a)
What is its describing function?
Check
A one-step MPC controls with weights 1 and 1, and 3.
(a)
What gain does the unconstrained one-step MPC apply?
(b)
Where is the closed-loop pole without saturation?
Have paper and a calculator ready. Work each problem out by hand, then enter the answer. Your first try on each one counts toward your score.
Practice
Keep practicing
16 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.