S9 · Lesson 7 · First- and second-order step responses
Time constants, rise and settling times, the second-order system's natural frequency and damping ratio, overshoot and peak time, and turning time-domain specifications into a region of the s-plane
"Settle within half a second with no more than 10% overshoot" is a typical requirement for a control loop. To design for it you need to know which pole locations produce which step responses. For first- and second-order systems the answer is exact and simple, and since most well-designed loops are dominated by one or two poles (lesson 8), these formulas are the working vocabulary of control design.
- The step response of , with sliders for the damping ratio ζ and the natural frequency .
- Lower ζ means more overshoot and more ringing; the readouts give the overshoot, peak time and 2% settling estimate.
- Raising with ζ fixed squeezes the whole response in time without changing its shape: overshoot depends on ζ alone.
Predict
A loop must overshoot no more than 10%. What's the least damping ratio its dominant poles can have?
Overshoot is , which equals 10% at ζ = 0.591. That's a cone in the s-plane: poles within ±53.8° of the negative real axis (cos⁻¹ 0.591).
Name it
First order
reaches 63% at τ, rises from 10% to 90% in and stays within 2% after .
Second order
For the step response is , with
- overshoot , so ;
- peak time ;
- settling time (2%) , from the envelope;
- rise time roughly near ζ = 0.5.
Specifications as a region
The poles sit at distance from the origin, at angle from the negative real axis. Overshoot sets a maximum angle, settling time a minimum (poles to the left of ), and rise time a minimum . A design puts the dominant poles inside all three regions.
Worked example
A loop has = 10 rad/s and ζ = 0.5. Predict its step response.
Show the solution
- Damped frequency and decay rate.
- Overshoot.
- Peak time.
- Settling time (2%). A simulation gives 0.81 s.
Answer it overshoots 16.3%, peaks at 0.363 s and settles within 2% by about 0.8 s.
Worked example
Find the s-plane region for at most 10% overshoot and 2% settling within 0.5 s.
Show the solution
- Overshoot limit. 10% overshoot needs ζ ≥ 0.591, which puts the poles within 53.8° of the negative real axis.
- Settling limit.
- Where the two meet. The slowest poles that do both sit where the cone meets the line σ = 8:
Answer the poles must lie within 53.8° of the negative real axis with σ of at least 8 s⁻¹; the slowest allowed poles have = 13.5 rad/s and = 10.9 rad/s.
Worked example
A step response overshoots by 25% and peaks at 0.2 s. Find ζ, and the settling time.
Show the solution
- Damping from the overshoot.
- Frequency from the peak time.
- Settling time (2%).
- What it shows. Two numbers read off a scope pin down the whole second-order model.
Answer ζ = 0.404 and = 17.2 rad/s, and it settles in about 0.58 s.
Check
A second-order system has ζ = 0.4. What's its step overshoot?
Check
What damping ratio gives 5% overshoot?
Check
A system with = 10 rad/s and ζ = 0.3. When does its step response peak?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
Estimate the 2% settling time for = 20 rad/s and ζ = 0.3.
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A first-order system has a time constant of 3 ms. What's its 10–90% rise time?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
A pair of poles sits at . What's their damping ratio?
Check
A step response overshoots by 15% and peaks at 0.05 s.
(a)
What is ζ?
(b)
What is ?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
A second-order system has damping ratio z and natural frequency w.
Step 1
What is the decay rate σ?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What is ?
Step 3
When does the step response peak?
Step 4
What is the overshoot (as a fraction)?
Explain why
Why does overshoot depend only on the damping ratio and not on the natural frequency?
Changing while holding ζ fixed moves the poles along a ray from the origin, which scales them all by the same factor. Scaling every pole by a factor k is the same as running the system's clock k times faster: the response has exactly the same shape, compressed in time. The peak value, and so the overshoot, doesn't change; only when it happens does. Overshoot is set by the ray's angle, which is , so it depends on ζ alone.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.