B4 · Lesson 5 · Temperature sensing
Platinum RTDs, thermistors, and the errors that creep in
Lesson 2 showed that a metal's resistance rises about 0.4% per degree. Engineers turn that into thermometers. A platinum wire of exactly 100 Ω at 0 °C, a Pt100, is the standard industrial sensor, steady and predictable to a tenth of a degree. A thermistor, a bead of semiconducting oxide, does the opposite: its resistance falls about 4% per degree, ten times more sensitive but strongly curved. Both are easy to read badly: the current that measures them heats them, and the wires to them add resistance of their own.
- The curves are a Pt100 and a 10 kΩ NTC thermistor, each divided by its resistance at 25 °C so they fit on one plot.
- The platinum line is nearly straight and shallow; the thermistor curve plunges, steepest when cold.
- The readouts give each one's resistance and its sensitivity in percent per degree at the marker.
Predict
A Pt100 is read by a meter through two copper leads, each 0.5 Ω, without compensation. About how far off is the temperature reading?
About 2.6 °C too high. The meter sees the sensor plus 1 Ω of leads, and a Pt100 changes only 0.385 Ω per degree, so 1 Ω looks like °C of extra warmth. That's why precision RTDs use three or four wires: separate wires carry the current and sense the voltage, so the leads' resistance drops out.
Name it
Platinum RTDs
A resistance temperature detector made of platinum follows, close enough for most work,
with in degrees Celsius and = 100 Ω for a Pt100 (1000 Ω for a Pt1000). That's 0.385 Ω per degree for a Pt100. The full standard (Callendar–Van Dusen) adds small curvature terms. Reading it backward: .
NTC thermistors
A thermistor's resistance falls steeply with temperature, nearly exponentially:
with temperatures in kelvin, K and β typically 3000 to 4500 K. Inverting: . Its sensitivity is , about −4.4% per degree at 25 °C: ten times a platinum sensor's, which suits cheap, narrow-range sensing like battery packs and room thermostats.
Errors
- Self-heating: the measuring current dissipates in the sensor, warming it by , where δ (the dissipation constant, in mW per °C) depends on mounting and airflow. Keep the current small: 1 mA in a Pt100 is 0.1 mW.
- Lead resistance: two-wire connections add the leads' resistance to the reading. A three-wire bridge cancels matched leads; a four-wire (Kelvin) connection removes them entirely.
Worked example
A Pt100 reads 109.5 Ω. What is the temperature? What would it read at 100 °C?
Show the solution
- Temperature.
- Reading at 100 °C.
Answer the temperature is 24.7 °C, and at 100 °C it would read 138.5 Ω.
Worked example
A 10 kΩ NTC thermistor with β = 3950 K reads 3.588 kΩ. What is the temperature, and what is its sensitivity at 25 °C?
Show the solution
- The β equation.
- Temperature. So K, which is 50.0 °C.
- Sensitivity at 25 °C.
Answer the thermistor is at 50.0 °C, and at 25 °C its sensitivity is −4.4% per degree.
Check
What does a Pt100 read at 150 °C?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A Pt100 reads 119.4 Ω. What is the temperature?
Check
A 10 kΩ NTC thermistor has β = 3450 K. What does it read at 10 °C?
Write units the way you normally would: 1.5 kΩ, 1500 Ω and 0.0015 MΩ are the same answer.
Check
A 10 kΩ NTC thermistor (β = 3450 K) reads 5 kΩ. What is the temperature?
Check
A Pt100 is wired with two leads of 0.5 Ω each, uncompensated. How large is the temperature error?
Check
A 100 Ω sensor carries 2 mA and has a dissipation constant of 5 mW/°C. How much does self-heating raise its temperature?
Explain why
Why does a four-wire connection remove lead resistance from an RTD reading?
In a four-wire connection, one pair of wires carries the measuring current through the sensor and a separate pair measures the voltage right at the sensor's terminals. The current-carrying leads do drop some voltage, but the voltmeter isn't across them. The sensing leads carry almost no current, because the voltmeter's input resistance is huge, so they drop almost nothing. The meter sees only the voltage across the sensor itself, and dividing by the known current gives the sensor's resistance alone.
Practice
Keep practicing
9 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.