B45 of 16
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

B4 · Lesson 5 · Temperature sensing

Platinum RTDs, thermistors, and the errors that creep in

Lesson 2 showed that a metal's resistance rises about 0.4% per degree. Engineers turn that into thermometers. A platinum wire of exactly 100 Ω at 0 °C, a Pt100, is the standard industrial sensor, steady and predictable to a tenth of a degree. A thermistor, a bead of semiconducting oxide, does the opposite: its resistance falls about 4% per degree, ten times more sensitive but strongly curved. Both are easy to read badly: the current that measures them heats them, and the wires to them add resistance of their own.

  • The curves are a Pt100 and a 10 kΩ NTC thermistor, each divided by its resistance at 25 °C so they fit on one plot.
  • The platinum line is nearly straight and shallow; the thermistor curve plunges, steepest when cold.
  • The readouts give each one's resistance and its sensitivity in percent per degree at the marker.

Predict

A Pt100 is read by a meter through two copper leads, each 0.5 Ω, without compensation. About how far off is the temperature reading?

Name it

Platinum RTDs

A resistance temperature detector made of platinum follows, close enough for most work,

R(T)=R0(1+αT),α=0.00385/°C

with T in degrees Celsius and R0 = 100 Ω for a Pt100 (1000 Ω for a Pt1000). That's 0.385 Ω per degree for a Pt100. The full standard (Callendar–Van Dusen) adds small curvature terms. Reading it backward: T=R/R0−1α.

NTC thermistors

A thermistor's resistance falls steeply with temperature, nearly exponentially:

R(T)=R25exp⁡[β(1T−1T25)]

with temperatures in kelvin, T25=298.15 K and β typically 3000 to 4500 K. Inverting: 1T=1T25+1βln⁡RR25. Its sensitivity is 1RdRdT=−βT2, about −4.4% per degree at 25 °C: ten times a platinum sensor's, which suits cheap, narrow-range sensing like battery packs and room thermostats.

Errors

  • Self-heating: the measuring current dissipates P=I2R in the sensor, warming it by P/δ, where δ (the dissipation constant, in mW per °C) depends on mounting and airflow. Keep the current small: 1 mA in a Pt100 is 0.1 mW.
  • Lead resistance: two-wire connections add the leads' resistance to the reading. A three-wire bridge cancels matched leads; a four-wire (Kelvin) connection removes them entirely.

Worked example

A Pt100 reads 109.5 Ω. What is the temperature? What would it read at 100 °C?

Show the solution
  1. Temperature. T=109.5/100−10.00385=24.7°C
  2. Reading at 100 °C. R=100(1+0.385)=138.5Ω

Answer the temperature is 24.7 °C, and at 100 °C it would read 138.5 Ω.

Worked example

A 10 kΩ NTC thermistor with β = 3950 K reads 3.588 kΩ. What is the temperature, and what is its sensitivity at 25 °C?

Show the solution
  1. The β equation. 1T=1298.15+ln⁡(0.3588)3950=0.0033540−0.0002595=0.0030945
  2. Temperature. So T=323.15 K, which is 50.0 °C.
  3. Sensitivity at 25 °C. −3950298.152=−4.4%per degree

Answer the thermistor is at 50.0 °C, and at 25 °C its sensitivity is −4.4% per degree.

Check

What does a Pt100 read at 150 °C?

Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.

Check

A Pt100 reads 119.4 Ω. What is the temperature?

Check

A 10 kΩ NTC thermistor has β = 3450 K. What does it read at 10 °C?

Write units the way you normally would: 1.5 kΩ, 1500 Ω and 0.0015 MΩ are the same answer.

Check

A 10 kΩ NTC thermistor (β = 3450 K) reads 5 kΩ. What is the temperature?

Check

A Pt100 is wired with two leads of 0.5 Ω each, uncompensated. How large is the temperature error?

Check

A 100 Ω sensor carries 2 mA and has a dissipation constant of 5 mW/°C. How much does self-heating raise its temperature?

Explain why

Why does a four-wire connection remove lead resistance from an RTD reading?

Practice

Keep practicing

9 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.