B4 Current, resistance and where energy flows · Practice
Measuring temperature with resistance
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
What does a Pt100 read at 150 °C?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A Pt100 reads 119.4 Ω. What is the temperature?
Check
A 10 kΩ NTC thermistor has β = 3450 K. What does it read at 10 °C?
Write units the way you normally would: 1.5 kΩ, 1500 Ω and 0.0015 MΩ are the same answer.
Check
A 10 kΩ NTC thermistor (β = 3450 K) reads 5 kΩ. What is the temperature?
Check
A Pt100 is wired with two leads of 0.5 Ω each, uncompensated. How large is the temperature error?
Check
A 100 Ω sensor carries 2 mA and has a dissipation constant of 5 mW/°C. How much does self-heating raise its temperature?
Check
What does a Pt1000 read at 20 °C?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
What is the sensitivity of a thermistor with β = 3500 K at 0 °C, in percent per degree?
Check
How much does a Pt100's resistance change over 18 °C?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in B4