C11 Measurement and lab practice · Practice
Accuracy, precision and uncertainty
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A meter specified as ±(0.05% of reading + 5 counts) reads 4.987 V on a range where one count is 0.01 V. What is the uncertainty?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Readings scatter with a standard deviation of 0.2 V. What is the standard error of the average of 4 readings?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Readings have σ = 0.5 mV. How many must be averaged for a standard error of 0.01 mV?
Check
How many counts can a 4½-digit display show at most?
Check
A reference of exactly 5 V reads as 10.2 V. What is the relative error?
Check
A meter reads 12.34 V with resolution 0.01 V. Its spec is ±(0.05% of reading + 5 counts).
(a)
What is the uncertainty?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What is that as a percentage of the reading?
Check
Readings scatter with s = 0.2 and the random error of their mean must be at most 0.01.
(a)
How many readings must be averaged?
(b)
What standard error does that give?
Check
Uncertainty of 3.3 V at ±(0.1% + 2 counts), count = 0.01 V?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Standard error of 9 readings with σ = 0.3 mV?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
Readings needed for error 0.25 with σ = 1?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in C11