C11 Measurement and lab practice · Practice
Grounding, ground loops and differential measurement
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
1 V of common mode reaches an input with 40 dB of CMRR. How much error does it cause?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
How much CMRR keeps 10 V of common mode to under 0.001 mV of error?
Check
A ground loop drives 100 mA through a cable shield of 0.005 Ω. How much voltage does it add to a single-ended measurement?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A loop of 100 cm² sits in a 0.1 mT field at 50 Hz. How much voltage is induced?
Write units the way you normally would: 1.5 µV, 1500 nV and 0.0015 mV are the same answer.
Check
Two scope channels' gains differ by 1%. About what CMRR does an A − B measurement achieve?
Check
A differential amplifier with 60 dB CMRR sees 5 V of common mode.
(a)
What error does that add?
Write units the way you normally would: 1.5 µV, 1500 nV and 0.0015 mV are the same answer.
(b)
And with 20 dB more CMRR?
Check
A 1 cm² loop sits in a 1 mT field at 60 Hz.
(a)
What peak voltage does it pick up?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
(b)
And with the loop area cut by ten (a twisted pair)?
Check
Error from 2 V common mode at 80 dB CMRR?
Write units the way you normally would: 1.5 µV, 1500 nV and 0.0015 mV are the same answer.
Check
Hum from 50 mA in a 0.02 Ω shield?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
CMRR of A − B with 0.5% gain mismatch?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in C11