C11 · Lesson 15 · Measuring power
From wall sockets to radio transmitters
Power looks like the simplest measurement, volts times amps, until the waveforms aren't sinusoids, the current isn't in phase with the voltage, or the signal is a radio carrier at 5 GHz where volts and amps can't be measured at all. Power meters handle each case differently: by multiplying samples, by heating a sensor, or by rectifying with a diode. Each has its own way to be wrong.
- The curves are the limits of the error caused by mismatch when an RF power sensor measures a source: the source reflects and the sensor , and the re-reflections between them add in an unknown phase.
- The error lies between and .
- With both well matched the error is a few hundredths of a decibel; with poor matches it can exceed the sensor's own accuracy several times over.
Predict
A source with |Γ| = 0.1 is measured by a sensor with |Γ| = 0.2. How large can the mismatch error be?
About ±0.17 dB: is +0.17 and −0.18 dB. That's comparable to a good sensor's own calibration uncertainty, so it often dominates an RF power budget. Adding a well-matched attenuator in front of the sensor reduces it.
Name it
Low-frequency power
Real power is the average of the instantaneous product,
which a digital power analyzer computes from simultaneous samples. Apparent power is , and the power factor is P divided by it: for sinusoids, lower for distorted currents such as a rectifier's. Measuring P as overstates it by the reciprocal of the power factor.
RF power and dBm
At radio frequencies, power is measured directly and quoted in dBm: , so 0 dBm is 1 mW, 30 dBm 1 W and −30 dBm 1 µW.
- Thermal sensors (thermistors, thermocouples) measure heating, which is true average power whatever the waveform, but slowly and only down to about −30 dBm.
- Diode sensors reach −70 dBm and respond fast. Below about −20 dBm a diode is square-law, its output proportional to power, and it reads true average power. Above that it moves toward peak detection, and reads modulated signals wrongly unless corrected.
Average and peak
Modulated signals have a peak-to-average power ratio (PAPR): 0 dB for a constant-envelope carrier, about 10 dB for OFDM. Amplifiers and sensors must handle the peaks, not just the average.
Mismatch
A sensor on a source that isn't perfectly matched receives a power that depends on the phase of the re-reflections between them, uncertain within .
Worked example
A 230 V supply drives a load drawing 5 A rms at a power factor of 0.8. What are the apparent and real powers?
Show the solution
- Apparent power.
- Real power.
- What a meter reads. A meter that multiplied rms voltage and rms current would read 1150, 25% high; a true wattmeter averages the instantaneous product and reads 920 W.
Answer the apparent power is 1150 VA, and the real power is 920 W.
Worked example
Convert 10 dBm, −30 dBm and 1 W to the other unit.
Show the solution
- 10 dBm.
- −30 dBm.
- 1 W. It is 1000 mW:
- Rules of thumb. Adding 3 dB doubles the power, and adding 10 dB multiplies it by ten.
Answer 10 dBm is 10 mW, −30 dBm is 1 µW, and 1 W is 30 dBm.
Worked example
An OFDM transmitter averages 20 dBm with a PAPR of 10 dB. What peak power must the amplifier and sensor handle?
Show the solution
- Peak power. That's 1 W of peak for 100 mW of average.
- A diode sensor. One operated near its square-law limit would be driven into its nonlinear region by the peaks and read high.
- What to use instead. That's why such signals are measured with a thermal sensor or a sensor characterized for wide-bandwidth modulation.
Answer 30 dBm, 1 W of peak.
Check
A load draws 2 A rms from 120 V rms at a power factor of 0.9.
(a)
What real power does it take?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
What is its apparent power?
Check
A signal measures −3 dBm.
(a)
What is its power in milliwatts?
Write units the way you normally would: 1.5 mW, 1500 µW and 0.0015 W are the same answer.
(b)
What rms voltage is that across 50 Ω?
Check
A source with |Γ| = 0.15 is measured by a sensor with |Γ| = 0.05.
(a)
What is the largest positive mismatch error?
(b)
And the largest negative one?
Check
A transmitter averages 23 dBm with a peak-to-average power ratio of 3 dB.
(a)
What is its peak power?
(b)
How many times the average is that?
Check
A rectifier load draws 4 A rms from 230 V with a power factor of 0.55.
(a)
By what factor would overstate its real power?
(b)
By how many watts?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
v and i are sinusoids of rms values V and I, with i lagging v by φ = f radians.
Step 1
What is the average of v·i?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What is the power factor?
Check
A diode power sensor reads accurately for a −40 dBm CW tone. Why might it read a +10 dBm OFDM signal wrongly?
Explain why
Why does a true wattmeter average the product v·i instead of multiplying the rms voltage by the rms current?
Power at each instant is v times i, and only the part of the current in phase with the voltage delivers energy on average. When the current lags or is distorted, some of it flows back and forth without doing net work, which the product of rms values counts as if it were useful. Averaging the instantaneous product cancels those back-and-forth parts exactly, leaving the real power. Multiplying rms values instead gives the apparent power, which is larger by the reciprocal of the power factor, and that's what sizes wiring and transformers but not what the load consumes.
Practice
Keep practicing
8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.