C1115 of 30
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

C11 · Lesson 15 · Measuring power

From wall sockets to radio transmitters

Power looks like the simplest measurement, volts times amps, until the waveforms aren't sinusoids, the current isn't in phase with the voltage, or the signal is a radio carrier at 5 GHz where volts and amps can't be measured at all. Power meters handle each case differently: by multiplying samples, by heating a sensor, or by rectifying with a diode. Each has its own way to be wrong.

  • The curves are the limits of the error caused by mismatch when an RF power sensor measures a source: the source reflects |Γs| and the sensor |ΓL|, and the re-reflections between them add in an unknown phase.
  • The error lies between 20log10⁡(1−|ΓsΓL|) and 20log10⁡(1+|ΓsΓL|).
  • With both well matched the error is a few hundredths of a decibel; with poor matches it can exceed the sensor's own accuracy several times over.

Predict

A source with |Γ| = 0.1 is measured by a sensor with |Γ| = 0.2. How large can the mismatch error be?

Name it

Low-frequency power

Real power is the average of the instantaneous product,

P=1T∫0Tv(t)i(t)dt

which a digital power analyzer computes from simultaneous samples. Apparent power is VrmsIrms, and the power factor is P divided by it: cos⁡ϕ for sinusoids, lower for distorted currents such as a rectifier's. Measuring P as Vrms×Irms overstates it by the reciprocal of the power factor.

RF power and dBm

At radio frequencies, power is measured directly and quoted in dBm: PdBm=10log10⁡(P/1 mW), so 0 dBm is 1 mW, 30 dBm 1 W and −30 dBm 1 µW.

  • Thermal sensors (thermistors, thermocouples) measure heating, which is true average power whatever the waveform, but slowly and only down to about −30 dBm.
  • Diode sensors reach −70 dBm and respond fast. Below about −20 dBm a diode is square-law, its output proportional to power, and it reads true average power. Above that it moves toward peak detection, and reads modulated signals wrongly unless corrected.

Average and peak

Modulated signals have a peak-to-average power ratio (PAPR): 0 dB for a constant-envelope carrier, about 10 dB for OFDM. Amplifiers and sensors must handle the peaks, not just the average.

Mismatch

A sensor on a source that isn't perfectly matched receives a power that depends on the phase of the re-reflections between them, uncertain within (1±|ΓsΓL|)2.

Worked example

A 230 V supply drives a load drawing 5 A rms at a power factor of 0.8. What are the apparent and real powers?

Show the solution
  1. Apparent power. 230V×5A=1150VA
  2. Real power. 1150×0.8=920W
  3. What a meter reads. A meter that multiplied rms voltage and rms current would read 1150, 25% high; a true wattmeter averages the instantaneous product and reads 920 W.

Answer the apparent power is 1150 VA, and the real power is 920 W.

Worked example

Convert 10 dBm, −30 dBm and 1 W to the other unit.

Show the solution
  1. 10 dBm. 1010/10=10mW
  2. −30 dBm. 10−30/10=10−3mW=1μW
  3. 1 W. It is 1000 mW: 10log10⁡1000=30dBm
  4. Rules of thumb. Adding 3 dB doubles the power, and adding 10 dB multiplies it by ten.

Answer 10 dBm is 10 mW, −30 dBm is 1 µW, and 1 W is 30 dBm.

Worked example

An OFDM transmitter averages 20 dBm with a PAPR of 10 dB. What peak power must the amplifier and sensor handle?

Show the solution
  1. Peak power. 20+10=30dBm That's 1 W of peak for 100 mW of average.
  2. A diode sensor. One operated near its square-law limit would be driven into its nonlinear region by the peaks and read high.
  3. What to use instead. That's why such signals are measured with a thermal sensor or a sensor characterized for wide-bandwidth modulation.

Answer 30 dBm, 1 W of peak.

Check

A load draws 2 A rms from 120 V rms at a power factor of 0.9.

(a)

What real power does it take?

Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.

(b)

What is its apparent power?

Check

A signal measures −3 dBm.

(a)

What is its power in milliwatts?

Write units the way you normally would: 1.5 mW, 1500 µW and 0.0015 W are the same answer.

(b)

What rms voltage is that across 50 Ω?

Check

A source with |Γ| = 0.15 is measured by a sensor with |Γ| = 0.05.

(a)

What is the largest positive mismatch error?

(b)

And the largest negative one?

Check

A transmitter averages 23 dBm with a peak-to-average power ratio of 3 dB.

(a)

What is its peak power?

(b)

How many times the average is that?

Check

A rectifier load draws 4 A rms from 230 V with a power factor of 0.55.

(a)

By what factor would Vrms×Irms overstate its real power?

(b)

By how many watts?

Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.

Check

v and i are sinusoids of rms values V and I, with i lagging v by φ = f radians.

Step 1

What is the average of v·i?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Check

A diode power sensor reads accurately for a −40 dBm CW tone. Why might it read a +10 dBm OFDM signal wrongly?

Explain why

Why does a true wattmeter average the product v·i instead of multiplying the rms voltage by the rms current?

Practice

Keep practicing

8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.