C11 Measurement and lab practice · Practice
Measuring power
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A load draws 2 A rms from 120 V rms at a power factor of 0.9.
(a)
What real power does it take?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
What is its apparent power?
Check
A signal measures −3 dBm.
(a)
What is its power in milliwatts?
Write units the way you normally would: 1.5 mW, 1500 µW and 0.0015 W are the same answer.
(b)
What rms voltage is that across 50 Ω?
Check
A source with |Γ| = 0.15 is measured by a sensor with |Γ| = 0.05.
(a)
What is the largest positive mismatch error?
(b)
And the largest negative one?
Check
A transmitter averages 23 dBm with a peak-to-average power ratio of 3 dB.
(a)
What is its peak power?
(b)
How many times the average is that?
Check
A rectifier load draws 4 A rms from 230 V with a power factor of 0.55.
(a)
By what factor would overstate its real power?
(b)
By how many watts?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
0 dBm in milliwatts?
Write units the way you normally would: 1.5 mW, 1500 µW and 0.0015 W are the same answer.
Check
Real power at 120 V, 3 A, PF 0.95?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
Upper mismatch error for |Γs| = 0.1, |ΓL| = 0.1?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in C11