C1119 of 30
0 XP
  1. Hook
  2. Problems

C11 · Problem set 3

Problem set 3: spectra, networks, power, noise and grounding

These problems use lessons 13 to 18: spectrum analyzers and decibels, network analyzers, measuring power, noise, averaging and lock-in detection, grounding and differential measurement, and low-level measurements. Room temperature is 300 K, where kT is 4.14 × 10⁻²¹ J and the thermal noise floor is −174 dBm/Hz.

Check

An analyzer with a 12 dB noise figure is set to 100 Hz RBW.

(a)

What noise floor does it show?

(b)

What would it show at a tenth of that RBW?

Check

A swept analyzer covers 10 MHz at 0.1 kHz RBW (k = 2).

(a)

About how long is a sweep?

Write units the way you normally would: 1.5 s and 1500 ms are the same answer.

(b)

How long at three times the RBW?

Check

A carrier is at 3 dBm, its second harmonic at −40 dBm and its third at −60 dBm.

(a)

What is the second harmonic in dBc?

(b)

What is the carrier's power in milliwatts?

Write units the way you normally would: 1.5 mW, 1500 µW and 0.0015 W are the same answer.

Check

A repeating signal with 5 mV of random noise is averaged over 100 sweeps.

(a)

What noise is left?

Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.

(b)

By how many dB has the SNR improved?

Check

A lock-in with time constant 1 s measures a source with 5 nV/√Hz of noise.

(a)

What is its noise bandwidth?

Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.

(b)

What noise does it see?

Check

A resistor of 10000 Ω at 300 K is measured over 1 Hz.

(a)

What is its thermal noise?

Write units the way you normally would: 1.5 nV, 1500 pV and 0.0015 µV are the same answer.

(b)

What is its noise density, in nV/√Hz?

Check

A differential amplifier with 50 dB CMRR sees 5 V of common mode.

(a)

What input-referred error results?

Write units the way you normally would: 1.5 µV, 1500 nV and 0.0015 mV are the same answer.

(b)

What CMRR would cut that error tenfold?

Check

A loop of 50 cm² sits in a 0.5 mT field at 50 Hz.

(a)

What does it pick up?

Write units the way you normally would: 1.5 µV, 1500 nV and 0.0015 mV are the same answer.

(b)

What would twisting the wires to cut the effective area tenfold leave?

Check

Two probes and A − B math measure a floating node with 1 V of common mode; the channels' gains differ by 0.2%.

(a)

What CMRR does that give?

(b)

What error appears on the difference?

Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.

Check

A −60 dBm tone is measured on an analyzer with 4 dB noise figure at 1000 Hz RBW.

(a)

What SNR does the display show?

(b)

What is the tone's power in picowatts?

Write units the way you normally would: 1.5 pW and 0.0015 nW are the same answer.

Check

A measurement needs 20 dB more SNR.

(a)

How many sweeps must be averaged?

(b)

By what factor must a lock-in's time constant grow instead (noise bandwidth shrinking in proportion)?

Check

A ground loop drives 20 mA through a 0.01 Ω shield; the signal is 10 mV.

(a)

How much hum does a single-ended measurement show?

Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.

(b)

What is the signal-to-hum ratio, in dB?

Have paper and a calculator ready. Work each problem out by hand, then enter the answer. Your first try on each one counts toward your score.

Practice

Keep practicing

16 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.